PHOENIX CONTACT SAC-5PY-M/2X 5,0-920 SAC-5PY-M/2X 5,0-920 1436097 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5PY-M/2X 5,0-920 1436097 PHOENIX CONTACT Bus system cable

SAC-5PY-M/2X 5,0-920

1436097

PHOENIX CONTACT

1 Pcs.

Bus system cable Bus system cable, CANopen®, DeviceNet™, 5-pole halogen-free, shielded, Straight M12 connector, coding: A SPEEDCON, to free cable end and free cable end, cable length: 5 m, Unshielded plug-in connector, The display is placed above pin 1 Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded, Plug straight M12 SPEEDCON, coding: A, on free cable end and free cable end, cable length: 5 m, Connector unshielded, Shield connected to pin 1

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

SAC-5PY-M/2X 5,0-920 1436097 PHOENIX CONTACT Bus system cable serves as a specialized networking drop or extension line designed to integrate automated nodes into standard fieldbus architectures. These pre-assembled communication lines maintain structured data flow and device interoperability within complex machinery networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable preassembled
  • Application: Standard
  • Sensor type: CANopen®
  • Number of positions: 5
  • Shielded: no
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Bus system: CANopen®/DeviceNet™
  • Signal type/category: CANopen®
  • Status display: no
  • Status display present: No
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 48 V AC
  • Nominal current I N: 4 A
  • Transmission medium: Copper

More info

▲
Technical data

Product properties
Product typeData cable preassembled
ApplicationStandard
Sensor typeCANopen®
Number of positions5
Shieldedno
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Bus systemCANopen®/DeviceNet™
Signal type/categoryCANopen®
DeviceNet™

Signaling
Status displayno
Status display presentNo

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Transmission mediumCopper

Material specifications
Flammability rating according to UL 94HB
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Dimensions
Dimensional drawing
Center distance21 mm

Connection data
Pin assignment
Contact Color (signal designation) Contact (optional)1 (Distributor) SR (shield)
2 (Distributor) RD (V+)
3 (Distributor) BK (V-)
4 (Distributor) WH (CAN_H)
5 (Distributor) BU (CAN_L)

Connector
Connection 1
TypePlug straight M12 SPEEDCON
Number of positions5
Locking typeSPEEDCON
Coding typeA (Standard)
Ambient temperature (operation)-25 °C ... 90 °C
Connection 2
Typefree cable end
Connection 3
Typefree cable end

Cable/line
Cable length5 m
CANopen®/DeviceNet™, PUR, violet [920]
Dimensional drawing
Cable weight90 kg/km
UL AWM Style21198 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™, PUR, violet [920]
Conductor structure2xAWG24/19+2xAWG22/19
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter6.70 mm ±0.3 mm
Outer sheath, materialPUR
External sheath, colorred lilac RAL 4001
Conductor materialTin-plated Cu litz wires
Material wire insulationFoamed PE (Data cable)
PE (Power supply)
Single wire, colorred-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering80 %
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance120 Ω ±10 % (with 1 MHz)
Cable capacitynom. 40 nF/km (Data cable)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation67 mm
Dynamic load capacity (bending)Max. bending cycles: 5000000, Bending radius: 70 mm, Bending radius: 10 x D, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: -20 °C ... 60 °C
Shield attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistanceIEC 60332-1-2
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
-20 °C ... 60 °C (for installation)
-20 °C ... 60 °C (cable, drag chain applications)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.