PHOENIX CONTACT SAC-5P-2,0-920/M12FS SAC-5P- 2,0-920/M12FS 1507476 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5P- 2,0-920/M12FS 1507476 PHOENIX CONTACT Bus system cable

SAC-5P-2,0-920/M12FS

1507476

PHOENIX CONTACT

1 Pcs.

Bus system cable Bus System Cable, CANopen®, DeviceNet™, 5-pole halogen-free, shielded, free cable end, to Straight female M12, encoding: A, cable length: 2 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A bus system cable serves to connect field devices, controllers, and communication nodes within an automated industrial network. This model, identified as Phoenix Contact SAC-5P- 2,0-920/M12FS, ensures protected, high-integrity data exchange across complex machinery layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 5
  • Cable length (EF000536): 2 m
  • Halogen free (EF000025): Yes
  • With LED indication (EF005950): No
  • Screened (EF000881): Yes
  • Vulcanize (EF004115): No
  • Rated current In (EF008250): 4 A
  • Rated voltage (EF000228): 48 V
  • Degree of protection (IP) (EF005474): IP65

More info

▲

Key Commercial Data

Orderkey1507476
Packing unit1 pc
Catalog pagePage 433 (C-2-2017)
GTIN4017918900274
Weight per Piece (excluding packing)140.120 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable2 m
Stripping length of the free conductor end50 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP65
IP67

General

NoteFurther products with variable cable lengths can be found in the accessories section
Rated current at 40°C4 A
Rated voltage48 V AC
60 V DC
Number of positions5
Insulation resistance≥ 100 MΩ
CodingA - standard
Signal type/categoryCANopen®
DeviceNet™
Status displayNo
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100
Torque0.4 Nm (M12 connector)

Material

Flammability rating according to UL 94HB
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Pin assignment

Contact | Color (signal designation) | Contact (optional)1 (Socket) | SR (shield)
2 (Socket) | RD (V+)
3 (Socket) | BK (V-)
4 (Socket) | WH (CAN_H)
5 (Socket) | BU (CAN_L)

Standards and Regulations

Flammability rating according to UL 94HB

Cable

Cable typeCAN Bus/DeviceNet
Cable type (abbreviation)920
UL AWM style21198 (80°C/300 V)
Cable structure2xAWG24/19+2xAWG22/19
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
AWG signal line24
AWG power supply22
Conductor structure signal line19x 0.13 mm
Conductor structure, voltage supply19x 0.15 mm
Core diameter including insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
Wire colorsRed-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
ShieldingTinned copper braided shield
Optical shield covering80 %
External sheath, colorviolet RAL 4001
External cable diameter D6.7 mm ±0,3 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Number of bending cycles5000000
Bending radius70 mm
Minimum bending radius, drag chain applications10 x D
Traversing path4.5 m
Traversing rate3 m/s
Acceleration3 m/s²
Cable weight90 kg/km
Outer sheath, materialPUR
Material conductor insulationFoamed PE (Data cable)
PE (Power supply)
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Cable capacitynom. 40 nF/km (Data cable)
Wave impedance120 Ω ±10 % (with 1 MHz)
Attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Flame resistanceUL 1581, Sec. 1060 (FT-1)
IEC 60332-1
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.