PHOENIX CONTACT SAC-4P-M 8MS/10,0-950 SAC-4P-M 8MS/10,0-950 1543265 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4P-M 8MS/10,0-950 1543265 PHOENIX CONTACT Bus system cable

SAC-4P-M 8MS/10,0-950

1543265

PHOENIX CONTACT

1 Pcs.

Bus system cable Bus system cable, INTERBUS, 4-pole halogen-free, shielded, M8 straight connector, coding: A, to free cable end, cable length: 10 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact SAC-4P-M 8MS/10,0-950 functions as a robust bus system cable, carrying high-speed protocol data between decentralized industrial nodes and automation controllers. Shielded construction protects network integrity from electromagnetic interference found near heavy motor drives and power transformers.

Current pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Number of poles (EF001391): 4
  • Cable length (EF000536): 10 m
  • Halogen free (EF000025): Yes
  • With LED indication (EF005950): No
  • Screened (EF000881): Yes
  • Vulcanize (EF004115): No
  • Rated current In (EF008250): 4 A
  • Rated voltage (EF000228): 48 V
  • Degree of protection (IP) (EF005474): IP65

More info

▲

Key Commercial Data

Orderkey1543265
Packing unit1 pc
Catalog pagePage 222 (C-6-2017)
GTIN4046356097420
Weight per Piece (excluding packing)423.800 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable10 m
Stripping length of the free conductor end50 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP65
IP67

General

Rated current at 40°C4 A
Rated voltage48 V AC
60 V DC
Number of positions4
Color handle areablack
Insulation resistance≥ 100 MΩ
CodingA - standard
Signal type/categoryINTERBUS
Status displayNo
Overvoltage categoryII
Degree of pollution3
Test voltage800 V
Torque0.2 Nm (M8 connectors)

Material

Flammability rating according to UL 94HB
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated

Pin assignment

Contact | Color (signal designation) | Contact (optional)1 (Plug) | RD (0.34 mm²)
3 (Plug) | BU (0.34 mm²)
2 (Plug) | YE (0.14 mm²)
4 (Plug) | GN (0.14 mm²)

Standards and Regulations

Flammability rating according to UL 94HB

Cable

Cable typeINTERBUS
Cable type (abbreviation)950
UL AWM style20963 (80°C/30 V)
Cable structure2xAWG26/19+2xAWG22/19
Conductor cross section2x 0.14 mm² (Signal line)
2x 0.34 mm² (Power supply)
1x 0.38 mm² (Drain wire)
AWG signal line26
AWG power supply22
Conductor structure signal line19x 0.10 mm
Conductor structure, voltage supply19x 0.15 mm
Core diameter including insulation0.97 mm (Signal line)
1.25 mm (Power supply)
Thickness, insulation0.24 mm (Conductor insulation, signal line)
0.25 mm (Conductor insulation, voltage supply)
Wire colorsred-blue, green-yellow
Twisted pairs2 cores to the pair
Type of pair shieldingAluminum-lined polyester foil
Overall twist2 pairs around a drain wire in the center to the core
ShieldingTinned copper braided shield
Optical shield covering85 %
External sheath, colorblack RAL 9005
Outer sheath thicknessapprox. 0.75 mm
External cable diameter D5.2 mm ±0.2 mm
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation7.5 x D
Number of bending cycles1000000
Bending radius110 mm
Traversing path6 m
Traversing rate4 m/s
Acceleration4 m/s²
Cable weight41 kg/km
Outer sheath, materialPUR
Material conductor insulationPP
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 20 MΩ*km
Conductor resistance≤ 150 Ω/km (Signal line)
≤ 58 Ω/km (Power supply)
Wave impedance75 Ω ±10 Ω (Signal line)
55 Ω ±10 Ω (Power supply)
Nominal voltage, cable≤ 100 V
Test voltage Core/Core1000 V (50 Hz, 1 min.)
Test voltage Core/Shield1000 V (50 Hz, 1 min.)
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-40 °C ... 80 °C (cable, flexible installation)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.