PHOENIX CONTACT SAC-5PY-F/2X 0,5-920-MS-FS SAC-5PY-F/2X 0,5-920-MS-FS 1436026 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-5PY-F/2X 0,5-920-MS-FS 1436026 PHOENIX CONTACT Bus system cable

SAC-5PY-F/2X 0,5-920-MS-FS

1436026

PHOENIX CONTACT

1 Pcs.

Bus system cable Bus System Cable, CANopen®, DeviceNet™, 5-pole halogen-free, shielded, Straight female M12, coding: A SPEEDCON, to Straight female M12, coding: A SPEEDCON and Straight connector M12, coding: A SPEEDCON, cable length: 0.5 m, all pluggable connectors unshielded, Display is positioned above pin 1 Bus system cable, CANopen®, DeviceNet™, 5-position, PUR halogen-free, red lilac RAL 4001, shielded, Socket straight M12 SPEEDCON, coding: A, on Socket straight M12 SPEEDCON, coding: A and Plug straight M12 SPEEDCON, coding: A, cable length: 0.5 m, all connectors unshielded, Shield connected to pin 1

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Phoenix Contact bus system cable (SAC-5PY-F/2X 0,5-920-MS-FS) is engineered to distribute network communication signals efficiently across industrial fieldbus nodes. Preassembled data distribution lines simplify branch connections within complex automation topologies while maintaining proper protocol impedance.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable preassembled
  • Application: Standard
  • Sensor type: CANopen®
  • Number of positions: 5
  • No. of cable outlets: 1
  • Shielded: no
  • Coding: A
  • Insulation characteristics Overvoltage category: II
  • Degree of pollution: 3
  • Bus system: CANopen®/DeviceNet™
  • Signal type/category: CANopen®
  • Status display: no
  • Status display present: No
  • Insulation resistance: ≥ 100 MΩ
  • Nominal voltage U N: 48 V AC
  • Nominal current I N: 4 A

More info

▲
Technical data

Product properties
Product typeData cable preassembled
ApplicationStandard
Sensor typeCANopen®
Number of positions5
No. of cable outlets1
Shieldedno
CodingA
Insulation characteristics
Overvoltage categoryII
Degree of pollution3

Interfaces
Bus systemCANopen®/DeviceNet™
Signal type/categoryCANopen®
DeviceNet™

Signaling
Status displayno
Status display presentNo

Electrical properties
Insulation resistance≥ 100 MΩ
Nominal voltage UN48 V AC
60 V DC
Nominal current IN4 A
Transmission mediumCopper

Material specifications
Flammability rating according to UL 94HB
Seal materialNBR
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialTPU GF
Material for screw connectionZinc die-cast, nickel-plated

Dimensions
Dimensional drawing
Center distance21 mm

Connection data
Pin assignment
Contact Color (signal designation) Contact (optional)1 (Distributor) SR (shield) 1 (Plug) 1 (Socket)
2 (Distributor) RD (V+) 2 (Plug) 2 (Socket)
3 (Distributor) BK (V-) 3 (Plug) 3 (Socket)
4 (Distributor) WH (CAN_H) 4 (Plug) 4 (Socket)
5 (Distributor) BU (CAN_L) 5 (Plug) 5 (Socket)

Connector
Connection 1
TypeSocket straight M12 SPEEDCON
Number of positions5
Locking typeSPEEDCON
Coding typeA (Standard)
Ambient temperature (operation)-25 °C ... 90 °C
Connection 2
TypeSocket straight M12 SPEEDCON
Number of positions5
Locking typeSPEEDCON
Coding typeA (Standard)
Ambient temperature (operation)-25 °C ... 90 °C
Connection 3
TypePlug straight M12 SPEEDCON
Number of positions5
Locking typeSPEEDCON
Coding typeA (Standard)
Ambient temperature (operation)-25 °C ... 90 °C

Cable/line
Cable length0.5 m
CANopen®/DeviceNet™, PUR, violet [920]
Dimensional drawing
Cable weight90 kg/km
UL AWM Style21198 (80°C/300 V)
Number of positions4
Shieldedyes
Cable typeCANopen®/DeviceNet™, PUR, violet [920]
Conductor structure2xAWG24/19+2xAWG22/19
Conductor structure signal line19x 0.13 mm
AWG signal line24
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
Wire diameter incl. insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
External cable diameter6.70 mm ±0.3 mm
Outer sheath, materialPUR
External sheath, colorred lilac RAL 4001
Conductor materialTin-plated Cu litz wires
Material wire insulationFoamed PE (Data cable)
PE (Power supply)
Single wire, colorred-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
Optical shield covering80 %
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Loop resistance≤ 181.80 Ω/km (Data cable)
≤ 114.80 Ω/km (Power supply)
Wave impedance120 Ω ±10 % (with 1 MHz)
Cable capacitynom. 40 nF/km (Data cable)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000.00 V (50 Hz, 1 min.)
Minimum bending radius, fixed installation5 x D
Minimum bending radius, flexible installation10 x D
Smallest bending radius, fixed installation34 mm
Smallest bending radius, movable installation67 mm
Dynamic load capacity (bending)Max. bending cycles: 5000000, Bending radius: 70 mm, Bending radius: 10 x D, Traversing path: 4.5 m, Traversing rate: 3 m/s, Acceleration: 3 m/s², Ambient temperature: -20 °C ... 60 °C
Shield attenuation≤ 22.9 dB/km (with 1 MHz)
≤ 16.4 dB/km (At 500 kHz)
≤ 9.5 dB/km (At 125 kHz)
Halogen-freein accordance with DIN VDE 0472 part 815
according to IEC 60754-1
Flame resistanceIEC 60332-1-2
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (Cable, flexible installation)
-20 °C ... 60 °C (for installation)
-20 °C ... 60 °C (cable, drag chain applications)

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP65
IP67

Standards and regulations
Standard designationM12 connector
Standards/specificationsIEC 61076-2-101

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.