View larger
SACB-8/ 8- 5,0PUR SCO P 1452518 PHOENIX CONTACT Sensor/actuator box, Application: Standard, Connection metho..
SACB-8/ 8-5,0PUR SCO P
1452518
PHOENIX CONTACT
1 Pcs.
Cables > Passive sensor-actuator interface (with cable)
QUICKON Installation System (QPD)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered to streamline control architecture, the Phoenix Contact sensor/actuator box (SACB-8/ 8-5,0PUR SCO P) aggregates multiple field signals into a single managed path. Such modular distribution units reduce wiring complexity and protect connections in standard industrial automation layouts.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Length of the preassembled cable (EF007300): 5 m
- Cable length configurable (EF007301): No
- Number of sensor-/actuator-slots (EF006939): 8
- Number of channels per connector slot (EF006885): 1
- Type of branches for sensor-/actuator cables (EF006972): M12
- Number of poles sensor/actuator slots (EF007402): 4
- Rated voltage (EF000228): 120 V
- Operating voltage (EF003983): 120 V
- Max. current carrying capacity per socket (EF004038): 2 A
- Max. total current (EF004039): 12 A
- Material of contact surface (EF004020): Gold
- Material insulation body (EF007543): Polyamide (PA)
- With LED indication (EF005950): No
- With potential separation (EF003272): No
- Connection for NPN-sensors (EF006817): Yes
- Fix cable version suitable for cable guide chain (EF007461): No
More info
▲General
| Rated voltage | 120 V |
|---|---|
| Current carrying capacity per I/O signal | 2 A |
| Current carrying capacity per slot | 4 A |
| Total rated current | 12 A |
| Number of positions | 4 |
| Number of slots | 8 |
| Flammability rating according to UL 94 | V0 |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 | |
| Ambient temperature (operation) | -25 °C ... 80 °C |
| -40 °C ... 90 °C (for fixed installation) | |
| -5 °C ... 80 °C (for flexible installation) |
Master cable connection data
| Connection method | Fixed connection |
|---|---|
| Length of cable | 5 m |
| Tightening torque slot sensor/actuator cable | 0.4 Nm |
| Tightening torque of mounting screw for fixing the housing | 0.5 Nm |
Insulation material
| Housing material | PBT |
|---|---|
| Material of the moulding mass | PUR |
| Contact material | Cu alloy |
| Contact surface material | Gold-plated |
| Contact carrier material | PA |
| Material of threaded sleeve | PBT |
| O-ring material | NBR |
Pin assignment
| Slot/position = Wire color or connection | 1 / 4 (A) = WH |
|---|---|
| 2 / 4 (A) = GN | |
| 3 / 4 (A) = YE | |
| 4 / 4 (A) = GY | |
| 5 / 4 (A) = PK | |
| 6 / 4 (A) = RD | |
| 7 / 4 (A) = BK | |
| 8 / 4 (A) = VT | |
| 1-8 / 1 (+ 120 V) = BN | |
| 1-8 / 3 (0 V) = BU | |
| 1-8 / 5 (PE) = GN/YE |
Cable
| Cable type | PUR/PVC black |
|---|---|
| Cable type (abbreviation) | PUR |
| Cable abbreviation | LiYY11Y-HF |
| UL AWM style | 20549 (80°C/300 V) |
| Conductor cross section | 8x 0.34 mm² (signal line) |
| 3x 0.75 mm² (power line) | |
| AWG signal line | 22 |
| AWG power supply | 18 |
| Conductor structure signal line | 19x 0.15 mm |
| Conductor structure, voltage supply | 42x 0.15 mm |
| Core diameter including insulation | 1.3 mm ±0.1 mm (signal line) |
| 1.8 mm ±0.1 mm (power line) | |
| Overall twist | Wires twisted in layers |
| External sheath, color | black RAL 9005 |
| Inner sheath thickness | ≥ 0.15 mm |
| Outer sheath thickness | ≥ 0.38 mm |
| External cable diameter D | 8.5 mm ±0.2 mm |
| Minimum bending radius, fixed installation | 7.5 x D |
| Minimum bending radius, flexible installation | 10 x D |
| Number of bending cycles | 1500000 |
| Minimum bending radius, drag chain applications | 10 x D |
| Traversing path | 2 m |
| Traversing rate | 2 m/s |
| Cable weight | 107.4 kg/km |
| Outer sheath, material | PUR |
| Material, inner sheath | PVC |
| Material conductor insulation | PVC |
| Conductor material | Bare Cu litz wires |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 2000 V |
| Special properties | Silicone-free |
| Flame resistance | DIN EN 50265 |
| Resistance to oil | As per VDE 0472 Part 803 |
| Other resistance | Highly resistant to acids, alkaline solutions and solvents |
| Ambient temperature (operation) | -40 °C ... 90 °C (cable, fixed installation) |
| -5 °C ... 80 °C (cable, flexible installation) |