View larger
SACB-8/16-L- 5,0 80MC SCO 1401199 PHOENIX CONTACT Sensor/actuator box
SACB-8/16-L-5,0 80MC SCO
1401199
PHOENIX CONTACT
1 Pcs.
Cables > Passive sensor-actuator interface (with cable)
QUICKON Installation System (QPD)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed by Phoenix Contact, the SACB-8/16-L-5,0 80MC SCO sensor/actuator box manages multiple input and output signals from automated machinery, routing them through a single cohesive cabling structure. Industrial distribution units like this reduce installation footprints and improve diagnostic efficiency across complex production lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Length of the preassembled cable (EF007300): 5 m
- Cable length configurable (EF007301): No
- Number of sensor-/actuator-slots (EF006939): 8
- Number of channels per connector slot (EF006885): 2
- Type of branches for sensor-/actuator cables (EF006972): M12
- Number of poles sensor/actuator slots (EF007402): 5
- Rated voltage (EF000228): 24 V
- Operating voltage (EF003983): 24 V
- Max. current carrying capacity per socket (EF004038): 2 A
- Max. total current (EF004039): 12 A
- Material of contact surface (EF004020): Gold
- Material insulation body (EF007543): Polyamide (PA)
- With LED indication (EF005950): Yes
- With potential separation (EF003272): No
- Connection for NPN-sensors (EF006817): No
- Fix cable version suitable for cable guide chain (EF007461): No
More info
▲Key Commercial Data
| Orderkey | 1401199 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 167 (C-4-2013) |
| GTIN | 4046356536110 |
| Weight per Piece (excluding packing) | 1,269.000 g |
| Custom tariff number | 85444290 |
| Country of origin | PL (Poland) |
General
| Rated voltage | 24 V DC |
|---|---|
| Max. operating voltage Umax | 30 V DC |
| Current carrying capacity per I/O signal | 2 A |
| Current carrying capacity per slot | 4 A |
| Total rated current | 12 A |
| Number of positions | 5 |
| Number of slots | 8 |
| Flammability rating according to UL 94 | V0 |
| Sensor/actuator connection system | M12-SPEEDCON-socket |
Ambient conditions
| Degree of protection | IP65 |
|---|---|
| IP67 | |
| IP69K | |
| Ambient temperature (operation) | -30 °C ... 90 °C |
| -40 °C ... 90 °C (cable, fixed installation) | |
| -5 °C ... 80 °C (cable, flexible installation) |
Master cable connection data
| Connection method | Fixed connection |
|---|---|
| Length of cable | 5 m |
| Tightening torque slot sensor/actuator cable | 0.4 Nm |
| Tightening torque of mounting screw for fixing the housing | 0.5 Nm |
Insulation material
| Housing material | PBT |
|---|---|
| Material of the moulding mass | PUR |
| Contact material | Cu alloy |
| Contact surface material | gold-plated |
| Contact carrier material | PA |
| Material of threaded sleeve | Zinc die-cast |
| Material of threaded sleeve surface | Nickel-plated |
| O-ring material | NBR |
Pin assignment
| Slot/position = Wire color or connection | 1 / 4 (A) = WH |
|---|---|
| 1 / 2 (B) = GY/PK | |
| 2 / 4 (A) = GN | |
| 2 / 2 (B) = RD/BU | |
| 3 / 4 (A) = YE | |
| 3 / 2 (B) = WH/GN | |
| 4 / 4 (A) = GY | |
| 4 / 2 (B) = BN/GN | |
| 5 / 4 (A) = PK | |
| 5 / 2 (B) = WH/YE | |
| 6 / 4 (A) = RD | |
| 6 / 2 (B) = YE/BN | |
| 7 / 4 (A) = BK | |
| 7 / 2 (B) = WH/GY | |
| 8 / 4 (A) = VT | |
| 8 / 2 (B) = GY/BN | |
| 1-8 / 1 (+ 24 V) = BN | |
| 1-8 / 3 (0 V) = BU | |
| 1-8 / 5 (PE) = GN/YE |
Standards and Regulations
| Standard designation | M12 connector |
|---|---|
| Standards/regulations | IEC 61076-2-101 |
| Flammability rating according to UL 94 | V0 |
Cable
| Cable type | PUR halogen-free, highly flexible |
|---|---|
| Cable type (abbreviation) | 80MC |
| Cable abbreviation | LS9Y11Y-J-EFK |
| Conductor cross section | 16x 0.5 mm² (Signal line) |
| 3x 1 mm² (power line) | |
| AWG signal line | 20 |
| AWG power supply | 17 |
| Conductor structure signal line | 28x 0.15 mm |
| Conductor structure, voltage supply | 56x 0.15 mm |
| Wire colors | brown, blue, green/yellow, white, green, yellow, gray, pink, red, black, violet, gray/pink, red/blue, white/green, brown/green, white/yellow, yellow/brown, white/gray, gray/brown |
| Overall twist | Wires twisted to an optimum in two layers |
| External sheath, color | black RAL 9005 |
| External cable diameter D | 10.75 mm |
| Smallest bending radius, fixed installation | 90 mm |
| Smallest bending radius, movable installation | 120 mm |
| Number of bending cycles | 5000000 |
| Bending radius | 120 mm |
| Traversing path | 5 m |
| Traversing rate | 3 m/s |
| Acceleration | 5 m/s² |
| Torsion force | ± 120 °/m (≥ 3 million torsion cycles) |
| Outer sheath, material | PUR |
| Material conductor insulation | PP |
| Conductor material | Bare Cu litz wires |
| Insulation resistance | ≥ 10 MΩ*km (at 20 °C) |
| Conductor resistance | 39 Ω/km (Signal line) |
| 19.5 Ω/m (power line) | |
| Nominal voltage, cable | 300 V |
| Test voltage, cable | 2000 V |
| Special properties | Silicone-free |
| Free of substances which would hinder coating with paint or varnish | |
| Flame resistance | DIN EN 50265-2-1 |
| Halogen-free | The cable is halogen-free |
| Resistance to oil | in accordance with DIN EN 60811-2-1 |
| Other resistance | somewhat resistant to welding sparks |
| Ambient temperature (operation) | -30 °C ... 70 °C (cable, fixed installation) |
| 5 °C ... 70 °C (cable, flexible installation) |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |