View larger
RBO 16-HC 3247989 PHOENIX CONTACT Bolt connection terminal block
RBO 16-HC
3247989
PHOENIX CONTACT
5 Pcs.
Automation > Feed-through terminal block
Enclosures connectivity
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for demanding rail transport environments, the RBO 16-HC 3247989 PHOENIX CONTACT Bolt connection terminal block handles high-current connections with robust reliability. Bolt connection terminal blocks are commonly deployed in heavy industrial and rolling stock applications where secure, vibration-resistant cable lug fastening is critical.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Bolt connection terminal block
- Product family: RBO
- Area of application: Railway industry
- Number of positions: 1
- Pitch: 54.8 mm
- Number of connections: 2
- Number of rows: 1
- Potentials: 1
- Data management status Article revision: 07
- Insulation characteristics Overvoltage category: III
- Degree of pollution: 3
- Rated surge voltage: 8 kV
- Maximum power dissipation for nominal condition: 16.22 W
- Number of connections per level: 2
- Nominal cross section: 300 mm²
- Stripping length: The stripping length depends on the specification provided by the cable lug manufacturer.
More info
▲| General | |
| Note | The rated insulation voltage applies to cable lugs for compression connection acc. to DIN 46235:1983-07 and for uninsulated cable lugs acc. to DIN 46234:1980-03 with path extension. |
| Product type | Bolt connection terminal block |
| Product family | RBO |
| Area of application | Railway industry |
| Machine building | |
| Plant engineering | |
| Number of positions | 1 |
| Pitch | 54.8 mm |
| Number of connections | 2 |
| Number of rows | 1 |
| Potentials | 1 |
| Data management status | |
| Article revision | 07 |
| Insulation characteristics | |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 8 kV |
| Maximum power dissipation for nominal condition | 16.22 W |
| Number of connections per level | 2 |
| Nominal cross section | 300 mm² |
| Stripping length | The stripping length depends on the specification provided by the cable lug manufacturer. |
| Connection in acc. with standard | IEC 60947-7-1 |
| Nominal current | 520 A |
| Maximum load current | 520 A (At a conductor cross section of 300 mm²) |
| Nominal voltage | 1000 V |
| Nominal cross section | 300 mm² |
| Cable lug connection DIN 46234:1980-03 | |
| Connection in acc. with standard | DIN 46234:1980-03 |
| Cross section | 25 mm² ... 300 mm² |
| Cross section range AWG | 4 ... 600 kcmil (converted acc. to IEC) |
| Hole diameter | 17 mm |
| Width | 38 mm |
| Bolt diameter | 16 mm |
| Screw thread | M16 |
| Tightening torque | 25 ... 35 Nm |
| Connection in acc. with standard | DIN 46235:1983-07 |
| Cross section | 25 mm² ... 300 mm² |
| Cross section range AWG | 4 ... 600 kcmil (converted acc. to IEC) |
| Hole diameter | 17 mm |
| Width | 48 mm |
| Bolt diameter | 16 mm |
| Screw thread | M16 |
| Tightening torque | 25 ... 35 Nm |
| Rated data (ATEX/IECEx) | |
| Identification | II 2 GD Ex eb IIC Gb |
| Operating temperature range | -60 °C ... 110 °C |
| Ex-certified accessories | 0800886 E/NS 35 N |
| List of bridges | / RBO 16-VS 2 / 3244685 |
| / RBO 16-VS 3 / 3244698 | |
| Bridge data | 520 A / 300 mm² |
| Ex temperature increase | 40 K (520 A / 300 mm²) |
| Rated voltage | 1100 V |
| for bridging with bridge | 1100 V |
| Rated insulation voltage | 1000 V |
| output | (Permanent) |
| Ex level General | |
| Rated current | 520 A |
| Maximum load current | 520 A |
| Contact resistance | 0.02 mΩ |
| Ex connection data General | |
| Torque range | 25 Nm ... 35 Nm |
| Nominal cross section | 300 mm² |
| Rated cross section AWG | 600 kcmil |
| Connection capacity rigid | 25 mm² ... 300 mm² |
| Connection capacity AWG | 4 ... 600 kcmil |
| Connection capacity flexible | 25 mm² ... 300 mm² |
| Connection capacity AWG | 4 ... 600 kcmil |
| 2 conductors with same cross section, solid | 25 mm² ... 300 mm² |
| 2 conductors with the same cross-section AWG rigid | 4 ... 600 kcmil |
| 2 conductors with same cross section, stranded | 25 mm² ... 300 mm² |
| 2 conductors with the same cross-section AWG flexible | 4 ... 600 kcmil |
| Dimensional drawing | |
| Width | 54.8 mm |
| Height | 283.5 mm |
| Depth on NS 35/7,5 | 91.8 mm |
| Depth on NS 35/15 | 99.3 mm |
| Bolt length | 45 mm |
| Pitch | 54.8 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Surge voltage test | |
| Test voltage setpoint | 9.8 kV |
| Result | Test passed |
| Temperature-rise test | |
| Requirement temperature-rise test | Increase in temperature ≤ 45 K |
| Result | Test passed |
| Short-time withstand current 300 mm² | 36 kA |
| Result | Test passed |
| Power-frequency withstand voltage | |
| Test voltage setpoint | 2.2 kV |
| Result | Test passed |
| Mechanical data | |
| Open side panel | No |
| Mechanical strength | |
| Result | Test passed |
| Attachment on the carrier | |
| DIN rail/fixing support | NS 35 |
| Test force setpoint | 20 N |
| Result | Test passed |
| Needle-flame test | |
| Time of exposure | 30 s |
| Result | Test passed |
| Oscillation/broadband noise | |
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Spectrum | Service life test category 1, class B, body mounted |
| Frequency | f1= 5 Hz to f2= 150 Hz |
| ASD level | 1.857 (m/s²)²/Hz |
| Acceleration | 0.8g |
| Test duration per axis | 5 h |
| Test directions | X-, Y- and Z-axis |
| Result | Test passed |
| Shocks | |
| Specification | DIN EN 50155 (VDE 0115-200):2008-03 |
| Pulse shape | Half-sine |
| Acceleration | 5g |
| Shock duration | 30 ms |
| Number of shocks per direction | 3 |
| Test directions | X-, Y- and Z-axis (pos. and neg.) |
| Result | Test passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, no longer than 24 h, -60°C to +70°C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Connection in acc. with standard | IEC 60947-7-1 |
| Mounting type | NS 35/7,5 |
| NS 35/15 | |
| direct screw connection |