PHOENIX CONTACT SAC-4PM12MSD/4,0-936/BP-M12FSD SAC-4PM12MSD/4,0-936/BP-M12FSD 1565968 PHOENIX CONTACT Bus system cable View larger
Images are for illustrative purposes only. Please refer to data sheet for details

SAC-4PM12MSD/4,0-936/BP-M12FSD 1565968 PHOENIX CONTACT Bus system cable

SAC-4PM12MSD/4,0-936/BP-M12FSD

1565968

PHOENIX CONTACT

1 Pcs.

Bus system cable

Automation > Sensor-actuator patch cord
Field Device Connectors (FDC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact bus system cable, specifically part number SAC-4PM12MSD/4,0-936/BP-M12FSD, provides dependable data communication channels for industrial networking standards. Industrial communication lines link distributed control nodes, drives, and controllers to maintain real-time process visibility. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Orderkey: 1565968
  • Packing unit: 1 pc
  • Minimum order quantity: 25 pc
  • Note: Made to Order (non-returnable)
  • GTIN: 4046356319867
  • Weight per Piece (excluding packing): 363.300 g
  • Custom tariff number: 85444290
  • Country of origin: PL (Poland)
  • Length of cable: 4 m
  • Ambient temperature (operation): -25 °C ... 90 °C (Plug / socket)
  • Degree of protection: IP65
  • Rated current at 40°C: 4 A
  • Rated voltage: 250 V
  • Number of positions: 4
  • Coding: D - data
  • Signal type/category: PROFINET

More info

▲

Key Commercial Data

Orderkey1565968
Packing unit1 pc
Minimum order quantity25 pc
NoteMade to Order (non-returnable)
GTIN4046356319867
Weight per Piece (excluding packing)363.300 g
Custom tariff number85444290
Country of originPL (Poland)

Dimensions

Length of cable4 m

Ambient conditions

Ambient temperature (operation)-25 °C ... 90 °C (Plug / socket)
Degree of protectionIP65
IP67

General

Rated current at 40°C4 A
Rated voltage250 V
Number of positions4
CodingD - data
Signal type/categoryPROFINET
Overvoltage categoryII
Degree of pollution3
Insertion/withdrawal cycles≥ 100

Material

Flammability rating according to UL 94V0
Contact materialCuSn
Contact surface materialNi/Au
Contact carrier materialPA 6.6
Material of grip bodyTPU, hardly inflammable, self-extinguishing
Material, knurlsZinc die-cast, nickel-plated
Sealing materialNBR

Standards and Regulations

Flammability rating according to UL 94V0

Cable

Cable typeEthernet
Cable type (abbreviation)936
Cable structure1x4xAWG22/7; SF/TQ
Conductor cross section4x 0.34 mm²
AWG signal line22
Conductor structure signal line7x 0.25 mm
Core diameter including insulation1.95 mm
Wire colorswhite-blue, orange-yellow
Overall twistStar quad
ShieldingPlastic-coated aluminum foil, tinned copper braided shield
Optical shield covering100 %
External sheath, colorblack RAL 9005
Outer sheath thickness≥ 0.8 mm
External cable diameter D7.25 mm ±0,3 mm
Minimum bending radius, fixed installation6 x D
Minimum bending radius, flexible installation10 x D
Cable weight81 g/m
Outer sheath, materialPE-X
Material conductor insulationPE-X
Conductor materialsilver-plated Cu litz wires
Conductor resistance≤ 54.4 Ω/km
Working capacitance≤ 65 pF (core-core)
≤ 100 pF (core-shield)
Wave impedance100 Ω ±5 Ω (f = 100 MHz)
Near end crosstalk attenuation (NEXT)80 dB (with 1 MHz)
76 dB (at 4 МHz)
67 dB (at 10 MHz)
60 dB (at 31.5 МHz)
56 dB (at 62.5 МHz)
53 dB (at 100 MHz)
Attenuation2 dB (with 1 MHz)
4 dB (at 4 МHz)
6.5 dB (at 10 MHz)
10.5 dB (at 31.5 МHz)
14 dB (at 62.5 МHz)
18 dB (at 100 MHz)
Return Loss35 dB (at 4 МHz)
35 dB (at 10 MHz)
35 dB (at 31.5 МHz)
33 dB (at 62.5 МHz)
33 dB (at 100 MHz)
Signal speed66 c
Shield attenuation40 dB (30 MHz ≤ f ≤ 100 MHz)
Coupling resistance200.00 mΩ/m (f ≤ 30 MHz)
Nominal voltage, cable300 V AC
Test voltage, cable2000 V AC (50 Hz, 5 minutes)
Fire protection in rail vehiclesBS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
UNI CEI 11170 (Risk level LR1 - LR4)
Flame resistanceEN 60332-1-2
EN 50266
EN 60332-3-25
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freeAccording to EN 50267-2-1
Resistance to oilaccording to IRM 902, 72 h at 100 °C
Other resistanceResistance to fuels according to IRM 903, 168 h at 70 °C
Concentration of fumesBS 6853 D.8.7
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosivenessEN 50267-2-2
Fume toxicityBS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)-50 °C ... 90 °C (cable, fixed installation)
-40 °C ... 90 °C (cable, flexible installation)

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.