View larger
BCP-508-17 GN 5448734 PHOENIX CONTACT Part plug,nominal Current: 12 A,rated Voltage (III/2): 320 V,N. º pole..
BCP-508-17 GN
5448734
PHOENIX CONTACT
100 Pcs.
Cables > Cable connector
PCB Connectors (PCC)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a dependable part plug, the Phoenix Contact BCP-508-17 GN (part number 5448734) provides robust connection interfaces for modern electronics. Component plugs are standard hardware in industrial hardware installations, permitting seamless wire-to-board integration in control panels and modular machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Contact type: Bus
- Number of poles: 17
- Number of plug-in contact rows: 1
- Modular spacing contacts: 5.08 mm
- Modular spacing connections: 5.08 mm
- Rated current In: 12 A
- Rated voltage: 320 V
- Rated surge voltage: 4 kV
- Over voltage category: III
- Pollution degree: 2
- Connectable conductor cross section solid-core: 0.2 mm²
- Type of electric connection: Screw connection
- Connectable cable type: Tubular cable
- Material of contact surface: Tin
- Material contact: Copper
- Material insulation body: Polyamide (PA)
More info
▲Commercial data
| Order key | 5448734 |
|---|---|
| Packaging unit | 100 pcs |
| Sell key | AAYBAA - |
| Minimum Order Quantity | 100 pcs |
| Ean | 4046356829106 |
| Weight per unit (excluding packaging) | 28,153 g |
| Tariff rate number | 85366990 |
| Country of origin | CN (China) |
General
| Article Family | BCP |
|---|---|
| Number of poles | 17 |
| Connection type | Screw connection with traction capsule |
| Insulating material group | I |
| Dimensioning transient voltage (III/3) | 4 kV |
| Dimensioning Transient Voltage (III/2) | 4 kV |
| Dimensioning transient voltage (II/2) | 4 kV |
| Dimensioning voltage (III/2) | 320 V |
| Sizing voltage (II/2) | 630 V |
| Standard-compliant connection | EN-VDE |
| Nominal Current IN | 12 A |
| Nominal Section | 2.5 mm² |
| Maximum Charging Current | 12 A (with a conductor cross-section of 2.5 mm²) |
| Isolation | PA |
| Combustibility class according to UL 94 | V0 |
| Length to be de-insulated | 7 mm |
| Min. tightening torque. | 0.4 Nm |
| Max. tightening torque. | 0.5 Nm |
Connection data
| Rigid conductor section min. | 0.2 mm² |
|---|---|
| Max. rigid conductor section | 2.5 mm² |
| Flexible conductor section min. | 0.2 mm² |
| Max. flexible conductor section | 2.5 mm² |
| Flexible conductor section with toe cap, without min plastic sleeve. | 0.25 mm² |
| Flexible conductor section with toe cap, without plastic sleeve max. | 2.5 mm² |
| Flexible conductor section with tip, with min plastic sleeve. | 0.25 mm² |
| Flexible conductor section with ferrule, with plastic sleeve max. | 2.5 mm² |
| Conductor section AWG min. | 24 |
| Conductor section AWG max. | 12 |
| 2 conductors with the same cross-section, rigid min. | 0.2 mm² |
| 2 conductors with the same cross-section, rigid max. | 1 mm² |
| 2 conductors with the same cross-section, flexible min. | 0.2 mm² |
| 2 conductors with the same cross-section, flexible max. | 1.5 mm² |
| 2 conductors with the same cross-section, flexible with HAE, without min plastic sleeve. | 0.25 mm² |
| 2 conductors with the same cross-section, flexible with HAE without plastic sleeve max. | 1 mm² |
| 2 conductors with the same cross-section, flexible with TWIN-AEH, with min plastic sleeve. | 0.5 mm² |
| 2 conductors with the same cross-section, flexible with TWIN-HAE with plastic sleeve max. | 1.5 mm² |
Standards & Specifications
| Standard-compliant connection | EN-VDE |
|---|---|
| CUL | |
| Combustibility class according to UL 94 | V0 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Time Span for Intended Use (EFUP): 50 years |
| You can find information about hazardous substances in the manufacturer's declaration under the "Downloads" tab |