View larger
ST-B250C1500 2802345 PHOENIX CONTACT Component connector
ST-B250C1500
2802345
PHOENIX CONTACT
10 Pcs.
Automation > Component plug terminal block
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ST-B250C1500 2802345 PHOENIX CONTACT Component connector acts as a specialized terminal block accessory designed to house discrete electronic components within modular wiring arrays. These terminal plugs allow technicians to seamlessly integrate resistors, diodes, or custom circuitry directly into standard rail-mounted systems.
Current pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Component plug terminal block
- Pitch: 12 mm
- Data management status Article revision: 05
- Width: 12 mm
- Height: 42 mm
- Depth: 41.6 mm
- Length: 42 mm
- Pitch: 12 mm
- Color: gray (RAL 7042)
- Flammability rating according to UL 94: V0
- Insulating material: PA
- Static insulating material application in cold: -60 °C
- Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
- Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
More info
▲| Product type | Component plug terminal block |
| Pitch | 12 mm |
| Data management status | |
| Article revision | 05 |
| Width | 12 mm |
| Height | 42 mm |
| Depth | 41.6 mm |
| Length | 42 mm |
| Pitch | 12 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material | PA |
| Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 130 °C |
| Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 28 MJ/kg |
| Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed |
| Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Ambient conditions | |
| Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | Plug-in mounting |