PHOENIX CONTACT AXL P AI8 P HART 1F AXL P AI8 P HART 1F 1215392 PHOENIX CONTACT Axioline P, Analog Input Module, Passive Analog Inputs: 8 (HART).. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL P AI8 P HART 1F 1215392 PHOENIX CONTACT Axioline P, Analog Input Module, Passive Analog Inputs: 8 (HART)..

AXL P AI8 P HART 1F

1215392

PHOENIX CONTACT

1 Pcs.

Axioline P, Analog Input Module, Passive Analog Inputs: 8 (HART), 0 mA ... 20 mA, 4 mA... 20 mA, connection technology: 2 conductors, transmission speed on the local bus: 100 MBit/s, HART - Functionality, protection index: IP20, Includes bus socket module and Axioline P male connectors Axioline P, Analog Input Module, Passive Analog Inputs: 8 (HART), 0 mA ... 20 mA, 4 mA... 20 mA, connection technology: 2 conductors, HART - Functionality, protection rating: IP20

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact Axioline P analog input module processes HART-enabled field signals within industrial control networks, enabling granular measurement and diagnostic data exchange from remote instrumentation. Such specialized I/O hardware is routinely implemented in hazardous or complex process industries requiring high-integrity sensor feedback.

Pricing, availability, and lead time are confirmed per enquiry through an RFQ.

  • Width: 53.6 mm
  • Height: 126.1 mm
  • Depth: 77.14 mm
  • Note on Measurement Indications: The depth is valid in the use of a symmetrical rail TH 35-7.5 (according to EN 60715).
  • Restriction of Use EMC Indication: EMC: Class A product, see manufacturer's statement in the download center
  • Colour: traffic grey A RAL 7042
  • Bus local Axioline P Connection type: Bus Socket Module
  • Transmission speed: 100 MBit/s
  • Analog Denomination Entry: Passive Analog Inputs
  • Ticket Description: Passive analog input signals, HART-ready
  • Number of Entries: 8 (HART)
  • Connection type: Push-in connection
  • Connection technology: 2 conductors
  • A Note on Connection Technology: shielded, braided in pairs
  • Input Signal Current: 0 mA ... 20 mA
  • Protection Circuit: Prot. Departures against Inv. polarity

More info

▲
Technical data

Dimensions
Dimension Scheme
Width53.6 mm
Height126.1 mm
Depth77.14 mm
Note on Measurement IndicationsThe depth is valid in the use of a symmetrical rail TH 35-7.5 (according to EN 60715).

Notes
Restriction of Use
EMC IndicationEMC: Class A product, see manufacturer's statement in the download center

Material Data
Colourtraffic grey A RAL 7042

Interfaces
Bus local Axioline P
Connection typeBus Socket Module
Transmission speed100 MBit/s

Input data
Analog
Denomination EntryPassive Analog Inputs
Ticket DescriptionPassive analog input signals, HART-ready
Number of Entries8 (HART)
Connection typePush-in connection
Connection technology2 conductors
A Note on Connection Technologyshielded, braided in pairs
Input Signal Current0 mA ... 20 mA
4 mA ... 20 mA
Protection CircuitProt. Departures against Inv. polarity

Item Properties
Constructionblockmodular
Product TypeI/O Component
Product FamilyAxioline P
Position for mountingat discretion (no temperature derating)
Insulation Properties
Surge CategoryIi
Degree of pollution2

Electrical Properties
Potentials: U Logic Voltage PowerL
Supply voltage19.2 V DC ... 30 V DC (via bus socket module (UL) to AXL P BK...)
Potentials: Axioline P (U local bus power)bus)
Supply voltage5 V DC (via bus socket module)
Current absorptionmax. 135 mA
Potentials: Supply voltage for Axioline P expansion module
Supply voltageUL(via bus socket module)
Current absorptionmax. 27 mA (via bus socket module)
Galvanic Separation/Isolation of Voltage Margins
Test voltage: 5 V power supply from local bus (UBus)/Functional Earth500 V AC, 62 Hz, 1 min.
Test voltage: 24 V power supply (periphery) / functional ground500 V AC, 62 Hz, 1 min.
Test Voltage: Field for Functional Ground500 V AC, 62 Hz, 1 min.
Test voltage: Field for 5 V and 24 V power supplies1500 V AC, 62 Hz, 1 min.

Connection data
Connection technology
Denomination ConnectionAxioline P Connector
Note about the connection typePlease note the instructions on cable sections in the user manual "Axioline P: System and Installation".
Connecting Conductors
Connection typePush-in connection
Rigid conductor section0.2 mm² ... 1.5 mm²
Flexible conductor section0.2 mm² ... 1.5 mm²
AWG Conductor Section24 ... 16
Length to be de-insulated8 mm
Axioline P Connector
Connection typePush-in connection
Note about the connection typePlease note the instructions on cable sections in the user manual "Axioline P: System and Installation".
Rigid conductor section0.2 mm² ... 1.5 mm²
Flexible conductor section0.2 mm² ... 1.5 mm²
AWG Conductor Section24 ... 16
Length to be de-insulated8 mm

Environmental and life-life conditions
Environmental conditions
Protection IndexIP20
Ambient Temperature (Service)-40 °C ... 70°C (Standard)
Protection IndexIP20
Air Pressure (Service)70 kPa ... 106 kPa (up to 2000 m above NN)
Air Pressure (Storage/Transport)70 kPa ... 106 kPa (up to 2000 m above NN)
Ambient Temperature (Storage/Transport)-40 °C ... 85 °C
Permissible air humidity (service)5 % ... 95% (non-condensing)
Permissible air humidity (storage/transport)5 % ... 95% (non-condensing)

Standards & Specifications
Kind of protectionIII (IEC 61140, EN 61140, VDE 0140-1)

Approvals
ATEX
MarkedII 3G Ex ec IIC T4 Gc
CertificateDEMKO 20 ATEX 2334X
IECEx
MarkedEx ec IIC T4 Gc
CertificateIECEx UL 20.0002X
UKCA Ex (UKEX)
MarkedII 3G Ex ec IIC T4 Gc
CertificatePxCAI22UKEx1052416X
Ex Data
UL, USA / CanadaClass I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, IIC T4

assembly
Type of mountingRail mounting
Position for mountingat discretion (no temperature derating)

Product Datasheet