View larger
AXL F PWM2 1H 1007352 PHOENIX CONTACT Axioline F, function module, pulse width modulation, transmission spee..
AXL F PWM2 1H
1007352
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - function-/technology module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact AXL F PWM2 1H is an Axioline F function module engineered for pulse width modulation tasks within industrial automation environments. Pulse width modulation units regulate power delivery to actuators, control motor speeds, and manage variable signal outputs in automated control cabinets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width: 35 mm
- Height: 126.1 mm
- Depth: 54 mm
- Note on dimensions: The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
- Note on application Note on application: Only for industrial use
- Axioline F local bus Number of interfaces: 2
- Connection method: Bus base module
- Transmission speed: 100 Mbps
- Module Input address area: 0 Byte
- Output address area: 8 Byte
- Required parameter data: 1 Byte
- Required configuration data: 6 Byte
- Signal Output name: PWM outputs
- Operating mode: PWM, pulse generator, push-pull output
- Connection method: Push-in connection
- Connection technology: 2-conductor
More info
▲| Dimensional drawing | |
| Width | 35 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
| Note on application | |
| Note on application | Only for industrial use |
| Axioline F local bus | |
| Number of interfaces | 2 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Module | |
| Input address area | 0 Byte |
| Output address area | 8 Byte |
| Required parameter data | 1 Byte |
| Required configuration data | 6 Byte |
| Signal | |
| Output name | PWM outputs |
| Operating mode | PWM, pulse generator, push-pull output |
| Connection method | Push-in connection |
| Connection technology | 2-conductor |
| Number of outputs | 2 |
| Frequency range | 0 Hz ... 65535 Hz |
| Pulse duty factor | 0 % ... 100 % |
| Nominal output voltage | 24 V (UO- 1.1 V) |
| 5 V DC | |
| Nominal current IN | max. 500 mA (at 24 V DC) |
| max. 10 mA (at 5 V DC) | |
| Nominal load, ohmic | max. 12 W (at 24 V DC nominal voltage) |
| max. 50 mW (at 5 V DC nominal voltage) | |
| Nominal load, inductive | max. 12 VA (at 24 V DC nominal voltage) |
| max. 50 mVA (at 5 V DC nominal voltage) | |
| Nominal load, lamp | max. 6 W (at nominal voltage) |
| Short-circuit-proof | yes |
| Short-circuit current | typ. 2.2 A (for approx. 1.2 µs, auto-retry after approx. 40 µs, 24 V output) |
| typ. 24 mA (5 V output) | |
| Transient surge protection | yes |
| Product type | I/O component |
| Product family | Axioline F |
| Type | block modular |
| Mounting position | any (no temperature derating) |
| Scope of delivery | including bus base module and Axioline F connectors |
| Special properties | Pulse width modulation |
| Data management status | |
| Article revision | 03 |
| Insulation characteristics | |
| Overvoltage category | II (IEC 60664-1, EN 60664-1) |
| Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
| Maximum power dissipation for nominal condition | 2.05 W |
| Potentials: Axioline F local bus supply (UBus) | |
| Supply voltage | 5 V DC (via bus base module) |
| Current draw | max. 150 mA |
| Potentials: Supply voltage input UO | |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC including all tolerances, including ripple |
| Current draw | max. 1.1 A |
| Protective circuit | Surge protection; electronic (35 V, 0.5 s) |
| Reverse polarity protection; parallel diode; with external 1 A fuse (for start-up only) | |
| Electrical isolation/isolation of the voltage ranges | |
| Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply of the local bus (UBus) / functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min. |
| Connection technology | |
| Connection name | Axioline F connector |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Axioline F connector | |
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Ambient conditions | |
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting |
| Mounting position | any (no temperature derating) |