PHOENIX CONTACT AXL F PWM2 1H AXL F PWM2 1H 1007352 PHOENIX CONTACT Axioline F, function module, pulse width modulation, transmission spee.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F PWM2 1H 1007352 PHOENIX CONTACT Axioline F, function module, pulse width modulation, transmission spee..

AXL F PWM2 1H

1007352

PHOENIX CONTACT

1 Pcs.

Axioline F, function module, pulse width modulation, transmission speed in local bus 100 Mbps, IP20 degree of protection, including bus base module and Axioline F male connectors AxiolineF, Function module, Pulse width modulation, local bus transmission rate:100 MBit/s, protection rating:IP20, including bus socket module and AxiolineF connectors

Automation > Fieldbus, decentr. periphery - function-/technology module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact AXL F PWM2 1H is an Axioline F function module engineered for pulse width modulation tasks within industrial automation environments. Pulse width modulation units regulate power delivery to actuators, control motor speeds, and manage variable signal outputs in automated control cabinets. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Width: 35 mm
  • Height: 126.1 mm
  • Depth: 54 mm
  • Note on dimensions: The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
  • Note on application Note on application: Only for industrial use
  • Axioline F local bus Number of interfaces: 2
  • Connection method: Bus base module
  • Transmission speed: 100 Mbps
  • Module Input address area: 0 Byte
  • Output address area: 8 Byte
  • Required parameter data: 1 Byte
  • Required configuration data: 6 Byte
  • Signal Output name: PWM outputs
  • Operating mode: PWM, pulse generator, push-pull output
  • Connection method: Push-in connection
  • Connection technology: 2-conductor

More info

Technical data

Dimensions
Dimensional drawing
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

Notes
Note on application
Note on applicationOnly for industrial use

Interfaces
Axioline F local bus
Number of interfaces2
Connection methodBus base module
Transmission speed100 Mbps

System properties
Module
Input address area0 Byte
Output address area8 Byte
Required parameter data1 Byte
Required configuration data6 Byte

Output data
Signal
Output namePWM outputs
Operating modePWM, pulse generator, push-pull output
Connection methodPush-in connection
Connection technology2-conductor
Number of outputs2
Frequency range0 Hz ... 65535 Hz
Pulse duty factor0 % ... 100 %
Nominal output voltage24 V (UO- 1.1 V)
5 V DC
Nominal current INmax. 500 mA (at 24 V DC)
max. 10 mA (at 5 V DC)
Nominal load, ohmicmax. 12 W (at 24 V DC nominal voltage)
max. 50 mW (at 5 V DC nominal voltage)
Nominal load, inductivemax. 12 VA (at 24 V DC nominal voltage)
max. 50 mVA (at 5 V DC nominal voltage)
Nominal load, lampmax. 6 W (at nominal voltage)
Short-circuit-proofyes
Short-circuit currenttyp. 2.2 A (for approx. 1.2 µs, auto-retry after approx. 40 µs, 24 V output)
typ. 24 mA (5 V output)
Transient surge protectionyes

Product properties
Product typeI/O component
Product familyAxioline F
Typeblock modular
Mounting positionany (no temperature derating)
Scope of deliveryincluding bus base module and Axioline F connectors
Special propertiesPulse width modulation
Data management status
Article revision03
Insulation characteristics
Overvoltage categoryII (IEC 60664-1, EN 60664-1)
Pollution degree2 (IEC 60664-1, EN 60664-1)

Electrical properties
Maximum power dissipation for nominal condition2.05 W
Potentials: Axioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current drawmax. 150 mA
Potentials: Supply voltage input UO
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC including all tolerances, including ripple
Current drawmax. 1.1 A
Protective circuitSurge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; parallel diode; with external 1 A fuse (for start-up only)
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os)500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / functional ground500 V AC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / functional ground500 V AC, 50 Hz, 1 min.

Connection data
Connection technology
Connection nameAxioline F connector
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection methodPush-in connection
Conductor cross section rigid0.2 mm² ... 1.5 mm²
Conductor cross section flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm
Axioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Conductor cross section AWG24 ... 16
Stripping length8 mm

Environmental and real-life conditions
Ambient conditions
Ambient temperature (operation)-25 °C ... 60 °C
Degree of protectionIP20
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)

Standards and regulations
Protection classIII (IEC 61140, EN 61140, VDE 0140-1)

Mounting
Mounting typeDIN rail mounting
Mounting positionany (no temperature derating)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.