An AXL F MA DALI2 1H 2702864 PHOENIX CONTACT Communication module serves as a bus coupler and interface unit designed to connect specialized sub-networks to modular automation control systems. These components facilitate seamless data routing and device communication within industrial control panel architectures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width: 35 mm
- Height: 126.1 mm
- Depth: 54 mm
- Note on dimensions: The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
- Note on application Note on application: Only for industrial use
- Axioline F local bus Number of interfaces: 2
- Connection method: Bus base module
- Transmission speed: 100 Mbps
- DALI Number of interfaces: 2
- Connection method: Push-in connection
- Fieldbus: DALI Designation: DALI
- Note: The data apply for DALI bus 1 and DALI bus 2, respectively.
- Connection method: Push-in connection
- No. of channels: 2 (DALI 1, DALI 2)
- Supply voltage: typ. 16 V DC (Bus voltage)
- Output current: 230 mA (guaranteed)
More info
▲| Dimensional drawing | |
| Width | 35 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715). |
| Note on application | |
| Note on application | Only for industrial use |
| Axioline F local bus | |
| Number of interfaces | 2 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| DALI | |
| Number of interfaces | 2 |
| Connection method | Push-in connection |
| Fieldbus: DALI | |
| Designation | DALI |
| Note | The data apply for DALI bus 1 and DALI bus 2, respectively. |
| Connection method | Push-in connection |
| No. of channels | 2 (DALI 1, DALI 2) |
| Supply voltage | typ. 16 V DC (Bus voltage) |
| Output current | 230 mA (guaranteed) |
| Output current with short-circuit | max. 250 mA |
| Current carrying capacity | max. 195 mA (Bus load, see derating) |
| Transmission speed | 1200 bps |
| Type of protection | Bus protected up to 250 V AC, maximum |
| Module | |
| Input address area | 8 Byte |
| Output address area | 8 Byte |
| Product type | I/O component |
| Product family | Axioline F |
| Type | block modular |
| Mounting position | any (no temperature derating) |
| Scope of delivery | including bus base module and Axioline F connectors |
| Special properties | Single client |
| two channels | |
| integrated DALI power supply unit | |
| Data management status | |
| Article revision | 04 |
| Insulation characteristics | |
| Overvoltage category | II (IEC 60664-1, EN 60664-1) |
| Pollution degree | 2 (IEC 60664-1, EN 60664-1) |
| Potentials: Axioline F local bus supply (UBus) | |
| Supply voltage | 5 V DC (via bus base module) |
| Current draw | max. 65 mA |
| Potentials: Feed-in of supply voltage (UI) | |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 470 mA (at nominal voltage) |
| typ. 250 mA | |
| Protective circuit | Surge protection; electronic (35 V, 0.5 s) |
| Reverse polarity protection; parallel diode; with external 5 A fuse | |
| Transient protection; Suppressor diode | |
| Electrical isolation/isolation of the voltage ranges | |
| Test voltage: 5 V supply of the local bus (UBus) / 24 V supply (I/Os) | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 5 V supply of the local bus (UBus) / functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min. |
| Test voltage: DALI 1 / DALI 2 | 500 V AC, 50 Hz, 1 min. |
| Test voltage: DALI / 5 V supply of the local bus (UBus) | 1.5 kV AC, 50 Hz, 1 min. |
| Test voltage: DALI/24 V supply (periphery) | 1.5 kV AC, 50 Hz, 1 min. |
| Test voltage: DALI/functional ground | 1.5 kV AC, 50 Hz, 1 min. |
| Connection technology | |
| Connection name | Axioline F connector |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor connection | |
| Connection method | Push-in connection |
| Conductor cross section rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Axioline F connector | |
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section, rigid | 0.2 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.2 mm² ... 1.5 mm² |
| Conductor cross section AWG | 24 ... 16 |
| Stripping length | 8 mm |
| Ambient conditions | |
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting |