Phoenix Contact AXL F LPSDO8/3 1F safety module monitors and executes safety-related switching functions within modular automation stations, protecting personnel and machinery in hazardous states. Safety output modules ensure reliable de-energization of connected loads when emergency stop or safety interlock conditions are triggered.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Number of digital inputs (EF001992): 0
- Number of digital outputs (EF001993): 4
- Digital inputs configurable (EF008516): No
- Digital outputs configurable (EF008520): No
- Type of voltage (input voltage) (EF003033): DC
- Output current (EF003202): 2 A
- Permitted voltage at output (EF007553): 24 V
- Short-circuit protection, outputs available (EF003203): No Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
More info
▲Key Commercial Data
| Orderkey | 2702171 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 300 (C-6-2017) |
| GTIN | 4055626004983 |
| Weight per Piece (excluding packing) | 222.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 53.6 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | Housing dimensions |
Ambient conditions
| Ambient temperature (operation) | -35 °C ... 60 °C (Mounting position: any) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 75 % (on average, 85% infrequently, non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 75 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 108 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above sea level) |
| Degree of protection | IP20 |
Digital outputs
| Output name | Digital outputs |
|---|---|
| Connection method | Direct plug-in technology |
| Connection technology | 2, 3-wire |
| Number of outputs | 4 (with two-channel assignment) |
| 8 | |
| Type of protection | Overload protection, freewheeling circuit for inductive loads, Discharge circuit for accelerated discharge of capacitive loads |
| Output voltage | 24 V DC |
| Output current | max. 2 A (per channel) |
| max. 1.5 A (per channel according to CULUS) | |
| max. 4 A (per group) | |
| max. 3 A (per group according to CULUS) | |
| max. 8 A (Total current of all outputs; Please observe the notes in the user manual.) | |
| max. 6 A (Total current of all outputs according to CULUS) | |
| Maximum output current per channel | 2 A |
| Maximum output current per module / terminal block | 8 A |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 222 g |
| Note on weight specifications | with connectors and bus base module |
Axioline potentials
| Designation | Axioline F local bus supply (UBus) |
|---|---|
| Supply voltage | 5 V DC (via bus base module) |
| Current consumption | typ. 260 mA (all outputs set; power supply by UOof 19.2 V DC to 30.2 V DC) |
| max. 280 mA | |
| Designation | Supply for digital output modules (UO) |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 25 mA (all outputs set; power supply by UOwith 30.2 V DC; without power supply to the actuator) |
| Type of protection | Protection against polarity reversal, EMC protective circuit, undervoltage detection |
SafetyBridge properties
| Connection to I/O modules | max. 16 (safe digital I/O modules) |
|---|---|
| Logic memory | 30 kByte |
Safety-related characteristic data
| Designation | IEC 61508 - High demand |
|---|---|
| Safety Integrity Level (SIL) | max. 3 (two channel; dependent in parameterization and wiring) |
| Designation | IEC 61508 - Low demand |
| Safety Integrity Level (SIL) | max. 3 (two channel; dependent in parameterization and wiring) |
| Designation | EN ISO 13849 |
| Performance level (PL) | max. e (two channel; dependent in parameterization and wiring) |
| Category | max. 4 (two channel; dependent in parameterization and wiring) |
| Designation | EN 62061 |
| Safety Integrity Level Claim Limit (SIL CL) | max. 3 (two channel; dependent in parameterization and wiring) |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |