View larger
AXL F BK PB XC 2702463 PHOENIX CONTACT Bus coupler
AXL F BK PB XC
2702463
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - communication module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact AXL F BK PB XC bus coupler acts as the gateway between fieldbus networks and modular I/O stations in industrial automation architectures. Bus couplers translate communication protocols, allowing distributed input and output modules to communicate efficiently with the main PLC.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Supporting protocol for EtherCAT (EF017564): No
- Supporting protocol for EtherNet/IP (EF007521): No
- Radio standard Bluetooth (EF007178): No
- Radio standard WLAN 802.11 (EF007179): No
- Radio standard GPRS (EF008523): No
- IO link master (EF007298): No
- System accessory (EF004118): Yes
- Degree of protection (IP) (EF005474): IP20
- With potential separation (EF003272): No
- Suitable for rail mounting (EF003972): Yes
- Wall mounting/direct mounting (EF007020): No
- Front built-in possible (EF007016): No
- Rack-assembly possible (EF007018): No
- Suitable for safety functions (EF001597): No
More info
▲Key Commercial Data
| Orderkey | 2702463 |
|---|---|
| Packing unit | 1 pc |
| GTIN | 4055626459271 |
| Weight per Piece (excluding packing) | 175.000 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 45 mm |
| Height | 125.9 mm |
| Depth | 74 mm |
| Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail) |
|---|---|
| -25 °C ... 55 °C (Standard; mounting position: any) | |
| -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
Connection data
| Designation | Axioline F connector |
|---|---|
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 175 g |
| Note on weight specifications | with connector and bus base module |
| Diagnostics messages | Diagnostic alarms |
Interfaces
| Designation | PROFIBUS DP |
|---|---|
| No. of channels | 1 |
| Connection method | D-SUB-9 female connector |
| Transmission speed | 9.6 kbps ... 12 Mbps |
| Number of positions | 9 |
| Designation | Axioline F local bus |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Designation | Service |
| Connection method | Micro USB type B |
System limits of the bus coupler
| Designation | System limits of the bus coupler |
|---|---|
| Amount of process data | max. 488 Byte (per station) |
| max. 244 Byte (Input) | |
| max. 244 Byte (Output) | |
| Number of parameter data | max. 244 Byte |
| Number of configuration data | max. 244 Byte |
| Number of supported devices | max. 63 (per station) |
| Number of local bus devices that can be connected | max. 63 |
Axioline potentials
| Designation | Communications power ULfeed-in (the supply of the Axioline F local bus UBusis generated from UL) |
|---|---|
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | max. 567 mA (with 2 A at UBusfor the I/Os and UL= 24 V) |
| Power consumption | max. 13.7 W (with 2 A load at UBusfor the I/Os) |
| Designation | Axioline F local bus supply (UBus) |
| Supply voltage | 5 V DC (via bus base module) |
| Power supply unit | 2 A |
| Type of protection | Surge protection of the supply voltage |
| Polarity reversal protection of the supply voltage |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |