AXL F BK EIP EF 2702782 PHOENIX CONTACT Bus coupler
AXL F BK EIP EF
2702782
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - communication module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
AXL F BK EIP EF 2702782 PHOENIX CONTACT Bus coupler links modular I/O nodes directly to Ethernet/IP control networks, facilitating seamless communication across industrial machinery. Such network couplers manage packet routing between the field bus and internal backplane architectures. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2702782
- Packing unit: 1 pc
- Catalog page: Page 102 (C-6-2017)
- GTIN: 4055626320533
- Weight per Piece (excluding packing): 230.700 g
- Custom tariff number: 85176200
- Country of origin: DE (Germany)
- Width: 45 mm
- Height: 126.1 mm
- Depth: 74 mm
- Note on dimensions: The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
- Ambient temperature (operation): -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail)
- Ambient temperature (storage/transport): -40 °C ... 85 °C
- Permissible humidity (operation): 5 % ... 95 % (non-condensing)
- Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
- Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m above sea level)
More info
▲Key Commercial Data
| Orderkey | 2702782 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 102 (C-6-2017) |
| GTIN | 4055626320533 |
| Weight per Piece (excluding packing) | 230.700 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 45 mm |
| Height | 126.1 mm |
| Depth | 74 mm |
| Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C (Mounting position: wall mounting on horizontal DIN rail) |
|---|---|
| -25 °C ... 55 °C (Mounting position: any) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
Connection data
| Designation | Axioline F connector |
|---|---|
| Connection method | Push-in connection |
| Note on the connection method | Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual. |
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 1.5 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 1.5 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 16 |
| Stripping length | 8 mm |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 230.7 g |
| Note on weight specifications | with connector and bus base module |
Interfaces
| Designation | EtherNet/IP™ |
|---|---|
| No. of channels | 2 |
| Connection method | RJ45 socket |
| Note on the connection method | Auto negotiation and autocrossing |
| Transmission speed | 10/100 Mbps (Half or full duplex mode (automatic detection, can be adjusted manually)) |
| Transmission physics | Ethernet in RJ45 twisted pair |
| Designation | Axioline F local bus |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Designation | Service |
| Connection method | Micro USB type B |
System limits of the bus coupler
| Number of supported devices | max. 63 (per station) |
|---|---|
| Number of local bus devices that can be connected | max. 63 |
Axioline potentials
| Designation | Communications power ULfeed-in (the supply of the Axioline F local bus UBusis generated from UL) |
|---|---|
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current consumption | max. 583 mA (with 2 A at UBusfor the I/Os and UL= 24 V) |
| Power consumption | max. 14 W (with 2 A load at UBusfor the I/Os) |
| Designation | Axioline F local bus supply (UBus) |
| Supply voltage | 5 V DC (via bus base module) |
| Power supply unit | 2 A |
| Type of protection | Surge protection of the supply voltage |
| Polarity reversal protection of the supply voltage |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
| No hazardous substances above threshold values |