View larger
AXL E PN IOL8 DI4 M12 6P 2701513 PHOENIX CONTACT Distributed I/O device
AXL E PN IOL8 DI4 M12 6P
2701513
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - digital I/O module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact distributed I/O device model AXL E PN IOL8 DI4 M12 6P functions as a rugged field-mounted module designed to capture sensor inputs and manage local device communication. By placing these nodes close to the machinery, installations reduce extensive hardwiring runs back to the main cabinet. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Voltage type (supply voltage) (EF002991): DC
- Number of digital inputs (EF001992): 4
- Number of digital outputs (EF001993): 0
- Digital inputs configurable (EF008516): No
- Digital outputs configurable (EF008520): No
- Input current at signal 1 (EF001428): 0.003 mA
- Permitted voltage at input (EF007554): -0.3 V
- Type of voltage (input voltage) (EF003033): DC
- Short-circuit protection, outputs available (EF003203): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
- Number of HW-interfaces parallel (EF003026): 0
More info
▲Key Commercial Data
| Orderkey | 2701513 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 199 (C-6-2017) |
| GTIN | 4046356763646 |
| Weight per Piece (excluding packing) | 543.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 60 mm |
| Height | 185 mm |
| Depth | 30.5 mm |
| Note on dimensions | The height is 212 mm including fixing clips. |
| Drill hole spacing | 198.5 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % |
| Permissible humidity (storage/transport) | 5 % ... 95 % |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP65/IP67 |
Interfaces
| Designation | PROFINET |
|---|---|
| No. of channels | 2 |
| Connection method | M12 fast connection technology |
| Note on the connection method | D-coded |
| Designation connection point | Copper cable |
| Transmission speed | 100 Mbps (with auto negotiation) |
| Number of positions | 4 |
System limits of the bus coupler
| Designation | PROFINET |
|---|---|
| Equipment type | PROFINET-Device |
| Conformance class | B |
| Number of supported application relationships (AR) | 2 |
| System-specific protocols | PROFINET protocols LLDP |
| PROFINET protocols MRP client | |
| PROFINET protocols DCP | |
| PROFINET protocols DCE-RPC | |
| Protocols supported | SNMP v1 |
| HTTP | |
| TFTP | |
| FTP |
Supply
| Designation | Module electronics and sensors (US) |
|---|---|
| Connection method | M12 connector (T-coded) |
| Number of positions | 4 |
| Supply voltage | 24 V DC |
| Nominal supply voltage range | 19.5 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 180 mA ±15 % (at 24 V DC) |
| Designation | Actuators (UA) |
| Connection method | M12 connector (T-coded) |
| Number of positions | 4 |
| Supply voltage | 24 V DC |
| Nominal supply voltage range | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 28 mA ±15 % (at 24 V DC) |
Digital inputs
| Input name | Digital inputs at pin 2 for type A ports |
|---|---|
| Description of the input | IEC 61131-2 type 1 |
| Connection method | M12 connector, X01 ... X04 have double occupancy |
| Connection technology | 3-wire |
| Number of inputs | 4 |
| Type of protection | Overload protection, short-circuit protection of sensor supply |
| Input filter time | < 1000 µs |
| Input voltage range "0" signal | -0.3 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Input frequency | 0.5 kHz |
| Nominal input current at UIN | typ. 3 mA |
| Description of the input | IO-Link ports in digital input (DI) mode |
| Connection method | M12 connector, X01 ... X04 have double occupancy |
| Connection technology | 3-wire |
| Number of inputs | max. 8 (EN 61131-2 type 1) |
| Nominal input voltage UIN | 24 V DC |
| Input voltage range "0" signal | -0.3 V DC ... 5 V DC |
| Input voltage range "1" signal | 15 V DC ... 30 V DC |
| Nominal input current | typ. 3 mA |
| Sensor current per channel | max. 200 mA (from L+/L-) |
| Total sensor current | max. 1.6 A (from L+/L-) |
| Input filter time | < 1000 µs |
| Input frequency | 0.5 kHz |
| Type of protection | Overload protection |
| Short-circuit protection for the sensor supply |
Digital outputs
| Output description | IO-Link ports in digital output (DO) mode |
|---|---|
| Connection method | M12 connector, X01 ... X04 have double occupancy |
| Connection technology | 3-wire |
| Number of outputs | max. 8 |
| Nominal output voltage | 24 V DC |
| Maximum output current per channel | 150 mA |
| Maximum output current per device | 1.2 A |
| Nominal load, ohmic | 3.6 W (160 Ω, at nominal load) |
| Nominal load, inductive | 3.6 VA (0.8 H, 160 Ω, at nominal load) |
| Signal delay | max. 150 µs (when switched on) |
| max. 200 µs (when switched off) | |
| Switching rate | 1 per second, maximum (at nominal inductive load) |
| Limitation of the voltage induced on circuit interruption | -15 V DC |
| Output voltage when switched off | max. 1 V |
| Output current when switched off | max. 300 µA |
| Type of protection | Overload protection |
| Short-circuit protection | |
| Behavior with overload | Shutdown with automatic restart |
Electrical isolation
| Test section | 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min. |
|---|---|
| 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. | |
| 24 V supply (communications power and sensor supply, IO-Link ports)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection (Ethernet 1)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection (Ethernet 2)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection (Ethernet 1)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, IO-Link ports) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min. |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 25; |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |