View larger
AXL E IOL TC4/K M12 2702983 PHOENIX CONTACT Axioline E IO-Link/analog converter with 4 analog TC inputs (typ..
AXL E IOL TC4/K M12
2702983
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact Axioline E IO-Link/analog converter bridges intelligent sensor networks with thermal measurement points, digitizing thermocouple inputs for streamlined industrial telemetry. These modular converters facilitate flexible topology expansion on factory floors without requiring complex cabinet retrofits.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Voltage type (supply voltage) (EF002991): DC
- Input, current (EF003204): No
- Input, voltage (EF003205): No
- Input, resistor (EF003206): No
- Input, resistance thermometer (EF003207): No
- Input, thermocouple (EF003208): Yes
- Input signal, configurable (EF003209): No
- Resolution of the analogue inputs (EF003575): 24 Bit
- Output, current (EF003212): No
- Output, voltage (EF003213): No
- Output signal configurable (EF003214): No
- Number of analogue inputs (EF001994): 0
- Number of analogue outputs (EF001995): 0
- Analogue inputs configurable (EF008518): No
- Analogue outputs configurable (EF008519): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
More info
▲Key Commercial Data
| Orderkey | 2702983 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 181 (C-6-2019) |
| GTIN | 4055626447261 |
| Weight per Piece (excluding packing) | 380.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 150 mm |
| Height | 54 mm |
| Depth | 118 mm |
| Note on dimensions | When installing, note the length of the M12 connector for the IO-Link cable and the bending radii of the TC cables. |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % |
| Permissible humidity (storage/transport) | 5 % ... 95 % |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP65 |
Electrical isolation
| Test section | IO-Link bus logic 500 V AC 50 Hz 1 min. |
|---|---|
| Thermocouple I/O devices 500 V AC 50 Hz 1 min. | |
| Functional earth ground 500 V AC 50 Hz 1 min. |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 50g, 11 ms period, half-sine shock pulse | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |