View larger
AXL E IOL SDI8 SDO4 2A M12 L 1185380 PHOENIX CONTACT Axioline E safety module, 4 secure digital inputs with ..
AXL E IOL SDI8 SDO4 2A M12 L
1185380
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - digital I/O module
Safety
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for decentralized automation architectures, the Phoenix Contact AXL E IOL SDI8 SDO4 2A M12 L Axioline E safety module provides secure signal processing directly in the field. Fieldbus safety modules offer robust environmental resistance while maintaining reliable communication of safety-related digital inputs and outputs.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Width: 59.8 mm
- Height: 214 mm
- Depth: 30 mm
- Note on Measurement Indications: Data incl. fixing tabs and plugs
- Shell material: Plastic POCAN B4239 GF30 YE 1018
- Digital Denomination Entry: Secure Digital Inputs
- Ticket Description: IEC 61131-2 Type 3
- Number of Entries: 4 (With 2 channel assignment)
- Cable length: max. 200 m
- Connection type: M12 plug-in connector (A-coded)
- Connection technology: 3 conductors
- Input Voltage Range Signal "0": -30 V DC ... 5 V DC
- Input Voltage Range Signal "1": 11 V DC ... 30.2 V DC
- Nominal Input Voltage U IN: 24 V DC
- Nominal input current to U IN: Typ. 3.7 mA (with 24 V DC)
- Inlet Filter Time: 1.5 ms
More info
▲| Dimension Scheme | |
| Width | 59.8 mm |
| Height | 214 mm |
| Depth | 30 mm |
| Note on Measurement Indications | Data incl. fixing tabs and plugs |
| Shell material | Plastic POCAN B4239 GF30 YE 1018 |
| Digital | |
| Denomination Entry | Secure Digital Inputs |
| Ticket Description | IEC 61131-2 Type 3 |
| Number of Entries | 4 (With 2 channel assignment) |
| 8 (With 1 channel assignment) | |
| Cable length | max. 200 m |
| Connection type | M12 plug-in connector (A-coded) |
| Connection technology | 3 conductors |
| Input Voltage Range Signal "0" | -30 V DC ... 5 V DC |
| Input Voltage Range Signal "1" | 11 V DC ... 30.2 V DC |
| Nominal Input Voltage UIN | 24 V DC |
| Nominal input current to UIN | Typ. 3.7 mA (with 24 V DC) |
| max. 4.3 mA (with 30.2 V DC) | |
| Inlet Filter Time | 1.5 ms |
| 3 ms (Default) | |
| 5 ms | |
| 15 ms | |
| Protection Circuit | Overload protection, short-circuit protection of sensor power |
| IO-Link | |
| Number of ports | 1 |
| Connection type | M12 plug-in connector, A-coded |
| Connection technology | 3 conductors |
| Port Model | Class A |
| Specification | V1.1.2 |
| Polarity reversal protection | Yes |
| Transmission speed | 230.4 kBit/s (COM3) |
| Cycle Time | ≥ 4 ms |
| Updating Process Data | ≥ 4 ms |
| Number of process data | 64 Bit (Input and Output Data) |
| Digital | |
| Denomination Output | Secure Digital Outputs |
| Connection type | M12 plug-in connector (A-coded) |
| Connection technology | 2 conductors |
| Number of outputs | 4 (with 2-channel assignment, +/- switching) |
| 4 (with 1-channel assignment, + switching) | |
| Protection Circuit | Overload protection, outputs short-circuit protection |
| Output voltage | Uto- 1.4 V |
| Output current | max. 2 A (per channel) |
| max. 2 A (per output) | |
| max. 6 A (Current sum of all outputs, please note the indications in the user manual.) | |
| Maximum Output Current Per Channel | 2 A |
| Nominal Output Voltage | 24 V DC (Voltage Us) |
| Min. Charge | 2.4 kΩ (10 mA at 24 V DC) |
| Output voltage in disconnected state | < 5 V (in Low state)) |
| Output current in disconnected state | 2 mA (Leakage current in "Low" state) |
| Delay Time | max. 128 s (parameterizable) |
| Permissible cable length | max. 50 m |
| Number of manoeuvres | max. 1 Hz |
| Resistance to return voltage, against short impulses | No |
| Construction | Stand-Alone |
| Product Type | I/O Component |
| Product Family | Axioline E |
| Position for mounting | discretionary |
| application | Functional safety |
| Operating Mode | 4-word process data service |
| Insulation Properties | |
| Degree of pollution | 4 |
| Power: IO-Link | |
| Denomination | IO-Link Port Power (L+) |
| Nominal Peripheral Supply Voltage | 24 V DC (Made available via the IO-Link interface of the IO-Link master.) |
| Supply voltage | 19.2 V DC ... 30.2 V DC (incl. all tolerances, incl. ripple) |
| Nominal current per device | approx. 15 mA |
| Permissible cable length | max. 20 m |
| Protection Circuit | Prot. Against polarity reversal |
| Power: Modular electronics and sensors | |
| Denomination | Power supply of modular electronics and sensors (Us) |
| Connection type | M12 connector (L-coded) |
| Number of poles | 2 |
| Supply voltage | 24 V DC |
| Supply voltage | 19.2 V DC ... 30.2 V DC (incl. all tolerances, incl. ripple) |
| Current absorption | 67 mA (Without Sensors) |
| Fuse protection | max. 8 A (slow) |
| Power: Actuators | |
| Denomination | Actuator Power (Uto) |
| Connection type | M12 connector (L-coded) |
| Number of poles | 2 |
| Supply voltage | 24 V DC |
| Supply voltage | 19.2 V DC ... 30.2 V DC (incl. all tolerances, incl. ripple) |
| Current absorption | 52 A (without actuators) |
| Fuse protection | max. 8 A (slow) |
| Connection type | M12 plug-in connector |
| Note about the connection type | according to IEC 61076-2-101, M12 connection technology |
| Environmental conditions | |
| Ambient Temperature (Service) | -25 °C ... 60°C (Mounting Position: Discretionary) |
| Protection Index | IP65/IP67 (according to DIN EN 60529:1989 + A1:1999 + A2:2013) |
| Observation | Resistant to hazardous gas for operation (sulfur dioxide (SO)2), hydrogen sulfide (H2S)) |
| Air Pressure (Service) | 70 kPa ... 108 kPa (up to 3000 m above NN) |
| Air Pressure (Storage/Transport) | 66 kPa ... 108 kPa (up to 3500 m above NN) |
| Ambient Temperature (Storage/Transport) | -40 °C ... 85 °C |
| Permissible air humidity (storage/transport) | 75% (non-condensing) |
| Kind of protection | III (IEC 61140, EN 61140, VDE 0140-1) |
| Creepage Lines and Air Isolation Distances | |
| Leak lines and air gaps | according to IEC 60664-1 |
| Position for mounting | discretionary |