The AXL E EC DI16 M12 6P Distributed I/O device manufactured by Phoenix Contact serves as an essential node for gathering signals from field sensors and transmitting them back to the primary control architecture in modular machine setups. These robust field-mounted blocks provide numerous discrete input channels to monitor binary process conditions across extended industrial environments.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Voltage type (supply voltage) (EF002991): DC
- Number of digital inputs (EF001992): 16
- Number of digital outputs (EF001993): 0
- Digital inputs configurable (EF008516): No
- Digital outputs configurable (EF008520): No
- Input current at signal 1 (EF001428): 0.003 mA
- Permitted voltage at input (EF007554): 0 V
- Type of voltage (input voltage) (EF003033): DC
- Short-circuit protection, outputs available (EF003203): No
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
- Number of HW-interfaces parallel (EF003026): 0
More info
▲Key Commercial Data
| Orderkey | 2701521 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 192 (C-6-2017) |
| GTIN | 4046356763714 |
| Weight per Piece (excluding packing) | 480.000 g |
| Custom tariff number | 85176200 |
| Country of origin | DE (Germany) |
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 60 mm |
| Height | 185 mm |
| Depth | 30.5 mm |
| Note on dimensions | The height is 212 mm including fixing clips. |
| Drill hole spacing | 198.5 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C |
|---|---|
| Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % |
| Permissible humidity (storage/transport) | 5 % ... 95 % |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP65/IP67 |
Interfaces
| Designation | EtherCAT® |
|---|---|
| No. of channels | 2 |
| Connection method | M12 fast connection technology |
| Note on the connection method | D-coded |
| Designation connection point | Copper cable |
| Transmission speed | 100 Mbps (with auto negotiation) |
| Number of positions | 4 |
System limits of the bus coupler
| Designation | EtherCAT® |
|---|---|
| Equipment type | EtherCAT®slave |
| System-specific protocols | Mailbox protocols CANopen®over EtherCAT® |
| Mailbox protocols File access over EtherCAT® | |
| Type of addressing | Auto-increment addressing |
| Fixed position addressing | |
| Logical addressing | |
| Specification | ETG.1000 V1.02 |
Supply
| Designation | Module electronics and sensors (US) |
|---|---|
| Connection method | M12 connector (T-coded) |
| Number of positions | 4 |
| Supply voltage | 24 V DC |
| Nominal supply voltage range | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 190 mA ±15 % (at 24 V DC) |
| Designation | Actuators (UA) for additional devices |
| Connection method | M12 connector (T-coded) |
| Number of positions | 4 |
| Supply voltage | 24 V DC |
| Nominal supply voltage range | 18 V DC ... 31.2 V DC (including all tolerances, including ripple) |
| Current consumption | typ. 3 mA ±15 % (at 24 V DC) |
Digital inputs
| Input name | Digital inputs |
|---|---|
| Description of the input | EN 61131-2 types 1 and 3 |
| Connection method | M12 connector, double occupancy |
| Connection technology | 4-wire |
| Number of inputs | 16 |
| Type of protection | Overload protection, short-circuit protection of sensor supply |
| Input filter time | < 1000 µs |
| Input voltage range "0" signal | 0 V ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Nominal input current at UIN | typ. 3 A |
Electrical isolation
| Test section | 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min. |
|---|---|
| 24 V supply (communications power and sensor supply, digital inputs)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. | |
| 24 V supply (communications power and sensor supply, digital inputs)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection (Ethernet 1)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection (Ethernet 2)/FE 500 V AC 50 Hz 1 min. | |
| Bus connection (Ethernet 1)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, digital inputs) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/bus connection (Ethernet 1) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/bus connection (Ethernet 2) 500 V AC 50 Hz 1 min. | |
| 24 V supply (actuator supply)/FE 500 V AC 50 Hz 1 min. |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 25; |
|---|---|