PHOENIX CONTACT AXL F UTH4 1H AXL F UTH4 1H 2688598 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F UTH4 1H 2688598 PHOENIX CONTACT I/O module

AXL F UTH4 1H

2688598

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Temperature recording module, Analogue inputs: 4 (4 inputs for thermocouples or linear voltage, additionally 1 input -5 V up to +5 V), connection technology: 2 conductors (shielded, twisted in pairs), transmission speed on the local bus: 100 MBit/s, protection rating: IP20, including bus socket module and AxiolineF connectors

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Integrating the Phoenix Contact AXL F UTH4 1H I/O module facilitates the accurate collection of industrial sensor data within distributed automation systems. These electronic terminal blocks are essential for linking process instrumentation to a broader control network. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Orderkey: 2688598
  • Packing unit: 1 pc
  • Catalog page: Page 119 (C-6-2017)
  • GTIN: 4046356780117
  • Weight per Piece (excluding packing): 144.000 g
  • Custom tariff number: 85389091
  • Country of origin: DE (Germany)
  • Width: 35 mm
  • Height: 126.1 mm
  • Depth: 54 mm
  • Note on dimensions: The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).
  • Ambient temperature (operation): -25 °C ... 60 °C
  • Ambient temperature (storage/transport): -40 °C ... 85 °C
  • Permissible humidity (operation): 5 % ... 95 % (non-condensing)
  • Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
  • Air pressure (operation): 70 kPa ... 106 kPa (up to 3000 m above sea level)

More info

▲

Key Commercial Data

Orderkey2688598
Packing unit1 pc
Catalog pagePage 119 (C-6-2017)
GTIN4046356780117
Weight per Piece (excluding packing)144.000 g
Custom tariff number85389091
Country of originDE (Germany)

Dimensions

Dimensional drawing
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight144 g
Note on weight specificationswith connectors and bus base module

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptiontyp. 112 mA
max. 160 mA
Power consumptiontyp. 0.54 W (logic)
max. 0.8 W (logic)
DesignationSupply for analog modules (UA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 23 mA
max. 40 mA
Power consumptionmax. 0.96 W (Peripherals)
typ. 1.05 W (entire device)
max. 1.76 W (entire device)
Type of protectionSurge protection of the supply voltage
Polarity reversal protection of the supply voltage
Transient protection

Analog inputs

Number of inputs4 +1 (4 inputs for thermocouples or linear voltage, plus 1 input -5 V to +5 V)
Input nameAnalog inputs
Description of the inputInputs for thermocouples or linear voltage
Connection methodSpring-cage connection with direct connector-in method
Connection technology2-wire (shielded, twisted pair)
Sensor types (RTD) that can be usedPt 100 (2 external cold junctions, can also be used as a sensor input)
Measuring principleSigma/Delta process
Measured value representation16 bits (15 bits + sign bit)
Resolution A/D24 bit
Type of protectionShort-circuit protection, overload protection of the inputs
Transient protection of inputs
Input filter time40 ms

Electrical isolation

Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications