PHOENIX CONTACT AXL F RTD4 1H AXL F RTD4 1H 2688556 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F RTD4 1H 2688556 PHOENIX CONTACT I/O module

AXL F RTD4 1H

2688556

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Temperature Recording Module, Analog Inputs: 4 (for resistive temperature sensors), Connection technology: 2, 3, 4 conductors (shielded), Transmission rate on local bus: 100 MBit/s, Protection rating: IP20, including bus socket module and AxiolineF connectors

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An AXL F RTD4 1H 2688556 PHOENIX CONTACT I/O module is utilized in industrial automation networks to interface resistance thermometers and temperature sensors with a central control system. These expansion modules process incoming field signals to monitor thermal variables across automated machinery and process lines.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Input, current (EF003204): No
  • Input, voltage (EF003205): No
  • Input, resistor (EF003206): Yes
  • Input, resistance thermometer (EF003207): Yes
  • Input, thermocouple (EF003208): No
  • Input signal, configurable (EF003209): No
  • Resolution of the analogue inputs (EF003575): 24 Bit
  • Output, current (EF003212): No
  • Output, voltage (EF003213): No
  • Output signal configurable (EF003214): No
  • Number of analogue inputs (EF001994): 0
  • Number of analogue outputs (EF001995): 0
  • Analogue inputs configurable (EF008518): No
  • Analogue outputs configurable (EF008519): No

More info

▲

Key Commercial Data

Orderkey2688556
Packing unit1 pc
Catalog pagePage 118 (C-6-2017)
GTIN4046356744201
Weight per Piece (excluding packing)144.000 g
Custom tariff number85389091
Country of originDE (Germany)

Dimensions

Dimensional drawing
CaptionDimensional drawing
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight144 g
Note on weight specificationswith connectors and bus base module

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptionmax. 140 mA
Power consumptionmax. 700 mW
DesignationSupply for analog modules (UA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 17 mA
Power consumptionmax. 400 mW
max. 1.1 W (at UBusand UA)
Type of protectionSurge protection of the supply voltage
Polarity reversal protection of the supply voltage
Transient protection

Analog inputs

Number of inputs4 (for resistance temperature detectors)
Input nameAnalog inputs
Description of the inputInputs for resistive temperature sensors
Connection methodSpring-cage connection with direct connector-in method
Connection technology2, 3, 4-wire (shielded)
Sensor types (RTD) that can be usedPt, Ni, KTY, Cu sensors
Linear resistance measuring range0 Ω ... 500 Ω
0 kΩ ... 5 kΩ
Nominal value of the current sources1 mA (Pt 100, Ni 100, RLin500 Ω; pulse current, the specification is valid during the sampling phase)
Measured value representation16 bits (15 bits + sign bit)
Resolution A/D24 bit
Type of protectionShort-circuit protection, overload protection of the inputs
Transient protection of inputs
Transient protection of sensor supplies
Data formatsIB IL, S7-compatible
Input filter time40 ms

Electrical isolation

Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values