View larger
AXL F CNT2 INC2 XC 1F 2701239 PHOENIX CONTACT Special function module
AXL F CNT2 INC2 XC 1F
2701239
PHOENIX CONTACT
1 Pcs.
Automation > Fieldbus, decentr. periphery - function-/technology module
I/O
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact AXL F CNT2 INC2 XC 1F is a special function module engineered for demanding industrial control systems requiring advanced counting and positioning tasks. Special function modules expand modular I/O node capabilities, allowing controllers to handle dedicated measurement and control algorithms locally. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Number of functions (EF003244): 1
- Number of HW-interfaces industrial Ethernet (EF003020): 0
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces serial TTY (EF003024): 0
- Number of HW-interfaces parallel (EF003026): 0
- Number of HW-interfaces wireless (EF006933): 0
- Number of HW-interfaces USB (EF003025): 0
- Number of HW-interfaces other (EF003027): 0
- With optical interface (EF003028): No
- Supporting protocol for EtherCAT (EF017564): No
- Supporting protocol for TCP/IP (EF003050): No
- Supporting protocol for PROFIBUS (EF003052): Yes
More info
▲Key Commercial Data
| Orderkey | 2701239 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 121 (C-6-2017) |
| GTIN | 4046356730082 |
| Weight per Piece (excluding packing) | 233.900 g |
| Custom tariff number | 85389091 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Dimensions
| Dimensional drawing | |
|---|---|
| Width | 53.6 mm |
| Height | 126.1 mm |
| Depth | 54 mm |
| Note on dimensions | The depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715). |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 60 °C (Standard) |
|---|---|
| -40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Degree of protection | IP20 |
General
| Mounting type | DIN rail |
|---|---|
| Net weight | 233.9 g |
| Note on weight specifications | with connectors and bus base module |
| Diagnostics messages | Short-circuit / overload of the digital outputs Yes |
| Error at the symmetrical incremental encoder Yes |
Interfaces
| Designation | Axioline F local bus |
|---|---|
| No. of channels | 2 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
Axioline potentials
| Designation | Axioline F local bus supply (UBus) |
|---|---|
| Supply voltage | 5 V DC (via bus base module) |
| Current consumption | typ. 100 mA |
| max. 120 mA | |
| Power consumption | typ. 0.5 W |
| max. 0.6 W | |
| Designation | Supply voltage input UI |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC including all tolerances, including ripple |
| Current consumption | max. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.) |
| Power consumption | max. 60 W (of which 1.6 W internal losses) |
| Type of protection | Surge protection of the supply voltage |
| Polarity reversal protection of the supply voltage | |
| Protection | max. 8 A (polarity reversal protection up to 5 A) |
Counter inputs
| Input name | Counter input for 24 V signals |
|---|---|
| Number of inputs | 2 (S1, S2) |
| Description of the input | EN 61131-2, type 3 |
| Connection method | Push-in connection |
| Input voltage | 24 V DC |
| Input voltage range "0" signal | -3 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Input frequency | max. 300 kHz (1 channel wired) |
| max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware) | |
| Input current | 2.5 mA (per channel) |
| Resolution | 32 bits |
| Permissible cable length to the sensor | 30 m |
Encoder inputs
| Input name | Incremental encoder inputs |
|---|---|
| Number of inputs | 2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2) |
| Connection method | Push-in connection |
| Encoder signals | Symmetrical and asymmetrical encoders |
| Cable length | 30 m |
Encoder data
| Number of 5 V encoder supplies | 2 (UE1, UE2) |
|---|---|
| Nominal output voltage | 5 V DC |
| Voltage range | 5 V DC ... 5.5 V DC |
| Current carrying capacity | max. 250 mA |
| Type of protection | Short-circuit protection |
| Number of 24 V encoder supplies | 2 (US1, US2) |
| Nominal output voltage | 24 V DC |
| Voltage range | 19.2 V DC ... 30 V DC |
| Current carrying capacity | typ. 500 mA |
| Type of protection | Short-circuit protection |
| Designation | Symmetrical incremental encoders |
| Encoder types that can be connected | max. 2 (A, /A, B, /B, (Z, /Z)) |
| Type of connection of signals | Push-in connection |
| Encoder supply voltage | 5 V DC |
| 24 V DC | |
| Signal voltage level | Differential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V, maximum |
| Common mode voltage range signal - ground | -10 V ... 13.2 V |
| Input frequency | max. 300 kHz (1 channel wired) |
| max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware) | |
| Designation | Asymmetrical incremental encoders |
| Encoder types that can be connected | max. 2 (A, B, (Z)) |
| Type of connection of signals | Push-in connection |
| Signal voltage level | Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum) |
| Input frequency | max. 300 kHz (1 channel wired) |
| max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware) |
Digital inputs
| Input name | Digital inputs |
|---|---|
| Description of the input | EN 61131-2, type 3 |
| Connection method | Push-in connection |
| Connection technology | 1-wire (optionally 2, 3-wire) |
| Number of inputs | 8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2) |
| Input voltage range "0" signal | -3 V DC ... 5 V DC |
| Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Nominal input current at UIN | 2.5 mA (per channel) |
Digital outputs
| Output name | Digital outputs |
|---|---|
| Connection method | Push-in connection |
| Connection technology | 1-wire |
| Number of outputs | 2 (Out1, Out2) |
| Type of protection | Short-circuit protection, overload protection of the outputs |
| Output voltage | 24 V DC |
| Nominal output voltage | 24 V DC |
| Maximum output current per channel | 500 mA |
| Nominal load, inductive | max. 12 VA (1.2 H, 48 Ω, with nominal voltage) |
| Nominal load, lamp | max. 12 W (at nominal voltage) |
| Nominal load, ohmic | max. 12 W (48 Ω, with nominal voltage) |
Standards and Regulations
| Mechanical tests | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g |
|---|---|
| Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g | |
| Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g | |
| Protection class | III, IEC 61140, EN 61140, VDE 0140-1 |
Environmental Product Compliance
| China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
|---|---|
| No hazardous substances above threshold values |