PHOENIX CONTACT AXL F DO16 FLK 1H AXL F DO16 FLK 1H 2701813 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F DO16 FLK 1H 2701813 PHOENIX CONTACT I/O module

AXL F DO16 FLK 1H

2701813

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Digital output module, Digital outputs:16, 24 VDC, 500 mA, connection technology:Connector for FLK (20 poles), transmission speed on the local bus:100 MBit/s, protection index: IP20, including bus base module and AxiolineF connector

Automation > Fieldbus, decentr. periphery - digital I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact AXL F DO16 FLK 1H I/O module provides reliable signal distribution and control interfacing within complex automation architectures. Such components process digital output commands from a central controller to operate industrial machinery.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Number of digital inputs (EF001992): 0
  • Number of digital outputs (EF001993): 16
  • Digital inputs configurable (EF008516): No
  • Digital outputs configurable (EF008520): No
  • Type of voltage (input voltage) (EF003033): DC
  • Output current (EF003202): 0.5 A
  • Permitted voltage at output (EF007553): 24 V
  • Short-circuit protection, outputs available (EF003203): Yes
  • Number of HW-interfaces industrial Ethernet (EF003020): 0
  • Number of interfaces PROFINET (EF006932): 0
  • Number of HW-interfaces RS-232 (EF003021): 0
  • Number of HW-interfaces RS-422 (EF003022): 0
  • Number of HW-interfaces RS-485 (EF003023): 0
  • Number of HW-interfaces serial TTY (EF003024): 0

More info

▲

Key Commercial Data

Orderkey2701813
Packing unit1 pc
Catalog pagePage 108 (C-6-2017)
GTIN4046356881302
Weight per Piece (excluding packing)108.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Dimensional drawing
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight108 g
Note on weight specificationswith connector and bus base module
Diagnostics messagesI/O supply failure can be parameterized via PDI object FF8Fhex
Short-circuit / overload of the digital outputs Yes

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptionmax. 120 mA
Power consumptionmax. 600 mW
DesignationSupply for digital output modules (UO)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptionmax. 8 A (provide external protection)
Power consumptionmax. 240 W (of which 560 mW with internal losses)
Type of protectionSurge protection of the supply voltage
Polarity reversal protection of the supply voltage
Protectionmax. 8 A (polarity reversal protection up to 5 A)

Digital outputs

Output nameDigital outputs
Connection methodFLK20 pin strip
Connection technologyFLK connector (20-pos.)
Number of outputs16
Type of protectionShort-circuit protection, overload protection of the outputs
Output voltage24 V
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module8 A (provide external protection)
Nominal load, inductivemax. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lampmax. 12 W (at nominal voltage)
Nominal load, ohmicmax. 12 W (48 Ω, with nominal voltage)

Electrical isolation

Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g, 11 ms period, half-sine shock pulse
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.