PHOENIX CONTACT AXL F AO4 1H AXL F AO4 1H 2688527 PHOENIX CONTACT I/O module View larger
Images are for illustrative purposes only. Please refer to data sheet for details

AXL F AO4 1H 2688527 PHOENIX CONTACT I/O module

AXL F AO4 1H

2688527

PHOENIX CONTACT

1 Pcs.

I/O module AxiolineF, Analog Output Module, Analog Outputs: 4, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA... 20 mA, 4 mA... 20 mA, connection technology: 2 conductors, transmission speed on local bus: 100 MBit/s, protection rating: IP20, including bus socket module and AxiolineF connectors

Automation > Fieldbus, decentr. periphery - analogue I/O module
I/O

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

The Phoenix Contact AXL F AO4 1H is an I/O module utilized in industrial automation networks to convert digital controller values into continuous analog signals for actuators, valves, and drives. Such devices manage precise process control loops within modular station architectures.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Supply voltage DC (EF007534): 19.2 V
  • Voltage type (supply voltage) (EF002991): DC
  • Input, current (EF003204): No
  • Input, voltage (EF003205): No
  • Input, resistor (EF003206): No
  • Input, resistance thermometer (EF003207): No
  • Input, thermocouple (EF003208): No
  • Input signal, configurable (EF003209): No
  • Output, current (EF003212): Yes
  • Output, voltage (EF003213): Yes
  • Output signal configurable (EF003214): Yes
  • Resolution of the analogue outputs (EF003577): 16 Bit
  • Number of analogue inputs (EF001994): 0
  • Number of analogue outputs (EF001995): 4
  • Analogue inputs configurable (EF008518): No
  • Analogue outputs configurable (EF008519): Yes

More info

▲

Key Commercial Data

Orderkey2688527
Packing unit1 pc
Catalog pagePage 117 (C-6-2017)
GTIN4046356744256
Weight per Piece (excluding packing)145.000 g
Custom tariff number85389091
Country of originDE (Germany)

Dimensions

Dimensional drawing
Width35 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7,5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on the connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Mounting typeDIN rail
Net weight145 g
Note on weight specificationswith connectors and bus base module

Interfaces

DesignationAxioline F local bus
No. of channels2
Connection methodBus base module
Transmission speed100 Mbps

Axioline potentials

DesignationAxioline F local bus supply (UBus)
Supply voltage5 V DC (via bus base module)
Current consumptiontyp. 120 mA
max. 150 mA
DesignationSupply for analog modules (UA)
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 60 mA (4 voltage channels, 10 V output)
max. 110 mA (4 current channels, 20 mA output, 500 Ω load)
Power consumptiontyp. 2.04 W (at UBusand UA)
max. 3.39 W (at UBusand UA)
Type of protectionSurge protection of the supply voltage
Polarity reversal protection of the supply voltage
Transient protection

Analog outputs

Number of outputs4
Connection methodPush-in connection
Connection technology2-wire
Note regarding the connection technologyshielded, twisted pair
Output nameAnalog outputs
D/A resolution16 bit
Type of protectionShort-circuit and overload protection
Transient protection
Protective circuit/componentElectronic
Suppressor diode
Data formatsIB IL, S7-compatible
Representation of output values16 bits (15 bits + sign)
Process data update140 µs
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
Load/output load current output≤ 500 Ω
Voltage output signal0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output> 1 kΩ
Precisiontyp. 0.1 % (of output range final value)

Electrical isolation

Test section5 V communications power (logic), 24 V supply (I/O) 500 V AC 50 Hz 1 min.
5 V supply (logic)/analog outputs 500 V AC 50 Hz 1 min.
5 V supply (logic)/functional earth ground 500 V AC 50 Hz 1 min.
24 V supply (I/O)/analog outputs 500 V AC 50 Hz 1 min.
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min.
Analog outputs/functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Mechanical testsVibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 5g
Shock in acc. with EN 60068-2-27/IEC 60068-2-27 30g
Continuous shock according to EN 60068-2-27/IEC 60068-2-27 10g
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.