View larger
AXC F 2152 2404267 PHOENIX CONTACT Controller
AXC F 2152
2404267
PHOENIX CONTACT
1 Pcs.
Automation > PLC CPU-module
Control Systems (CST)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Managed through the AXC F 2152 2404267 PHOENIX CONTACT Controller by Phoenix Contact, this modular industrial controller serves as a central processing unit for automated industrial equipment and machinery. Processing hardware interfaces and managing field devices, such units maintain reliable control loops and data exchange across complex production systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Supply voltage DC (EF007534): 19.2 V
- Voltage type (supply voltage) (EF002991): DC
- Model (EF000010): Modular
- Number of HW-interfaces industrial Ethernet (EF003020): 2
- Number of interfaces PROFINET (EF006932): 0
- Number of HW-interfaces RS-232 (EF003021): 0
- Number of HW-interfaces RS-422 (EF003022): 0
- Number of HW-interfaces RS-485 (EF003023): 0
- Number of HW-interfaces USB (EF003025): 0
- Number of HW-interfaces parallel (EF003026): 0
- Number of HW-interfaces wireless (EF006933): 0
- Number of HW-interfaces other (EF003027): 1
- Number of analogue outputs (EF001995): 0
- Number of analogue inputs (EF001994): 0
- Number of digital inputs (EF001992): 0
- Number of digital outputs (EF001993): 0
More info
▲Key Commercial Data
| Orderkey | 2404267 |
|---|---|
| Packing unit | 1 pc |
| GTIN | 4055626356280 |
| Weight per Piece (excluding packing) | 387.000 g |
| Custom tariff number | 85371091 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C ... 60 °C up to 2000 m above mean sea level (observe derating) |
| -25 °C ... 55 °C up to 3000 m above mean sea level (observe derating) | |
| ≤ 55 °C (with max. 1 A on UBus) | |
| > 55 °C ... 60 °C (only in conjunction with an Axioline F power module AXL F PWR 1H (order number 2688297)) | |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (operation) | 5 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (according to DIN EN 61131-2) |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 58 kPa ... 106 kPa (up to 4500 m above mean sea level) |
| Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
Control system
| Engineering tool | PLCnext Engineer |
|---|---|
| Eclipse | |
| Programming languages supported | Programming in acc. with IEC 61131-3 |
| C++ | |
| Manufacturer-specific |
IEC 61131 runtime system
| Engineering tool | PLCnext Engineer |
|---|---|
| Eclipse | |
| Program memory | 8 Mbyte |
| Mass storage | 16 Mbyte |
| Retentive mass storage | 48 kByte (NVRAM) |
| Realtime clock | Yes |
Fieldbus function
| Designation | |
|---|---|
| Amount of process data | max. 8192 Bit (per station) |
| max. 4096 Bit (Input) | |
| max. 4096 Bit (Output) | |
| Number of supported devices | max. 63 (per station) |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) |
Data interfaces
| Interface | Axioline F local bus |
|---|---|
| Number | 1 |
| Connection method | Bus base module |
| Transmission speed | 100 Mbps |
| Interface | Ethernet |
| Number | 2 |
| Connection method | RJ45 socket |
| Transmission speed | 10/100 Mbps (full duplex) |
PROFINET
| Device function | PROFINET controller, PROFINET device |
|---|---|
| Specification | Version 2.3 |
| Update rate | min. 1 ms (4 devices) |
| min. 16 ms (64 devices) |
Power supply
| Typical current consumption | 200 mA (without I/Os and UL= 24 V) |
|---|---|
| Max. current consumption | 442 mA (with 1 A at UBusfor the I/Os and UL= 24 V) |
| Supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC |
Standards and Regulations
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Interference emission | Noise emission test as per EN 61000-6-4 Class A |
| Immunity to surge | Noise immunity test in accordance with EN 61000-6-2 Transient overvoltage (surge) EN 61000-4-5/IEC 61000-4-5 Criterion B, DC supply lines: ±0.5 kV/±0.5 kV (symmetrical/asymmetrical), fieldbus cable shield: ±1 kV |
| Immunity to burst | Noise immunity test in accordance with EN 61000-6-2 Fast transients (burst) EN 61000-4-4/IEC 61000-4-4 Criterion B, 2 kV |
| Immunity to EF | Noise immunity test in accordance with EN 61000-6-2 Electromagnetic fields EN 61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m |
| Immunity to ESD | Noise immunity test in accordance with EN 61000-6-2 Electrostatic discharge (ESD) EN 61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge |
| Immunity to conducted interference | Noise immunity test in accordance with EN 61000-6-2 Conducted interference EN 61000-4-6/IEC 61000-4-6 Criterion A; Test voltage 10 V |
| Vibration (storage/transport) | 5g |
| Shock | 30g, 11 ms period, half-sine shock pulse, according to IEC 60068-2-27 |
| Vibration (operation) | 5g |
| Shock (operation) | 10g (Bump endurance test according to EN 60068-2-29) |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |