View larger
C-TV-SAT 2856993 PHOENIX CONTACT Attachment plug with surge protection for antenna inputs with F connector
C-TV-SAT
2856993
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact C-TV-SAT is an attachment plug with surge protection designed to secure sensitive antenna inputs against transient voltage spikes in industrial and commercial networks. Such devices are typically installed directly on signal pathways to divert harmful electrical surges safely to the ground plane, preventing costly downtime and equipment failure. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Height: 44 mm
- Width: 28 mm
- Depth: 66 mm
- Ambient temperature (operation): -25 °C ... 75 °C
- Degree of protection: IP20
- Housing material: PA
- Flammability rating according to UL 94: V0
- Color: black
- Standards for cearances and creepage distances: DIN VDE 0110-1
- Overvoltage category: II
- Pollution degree: 2
- Mounting type: Connection-specific intermediate plugging
- Type: Attachment plug
- Number of positions: 1
- Direction of action: Line-Shield/Earth Ground
- IEC test classification: C1
More info
▲Dimensions
| Height | 44 mm |
|---|---|
| Width | 28 mm |
| Depth | 66 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 75 °C |
|---|---|
| Degree of protection | IP20 |
General
| Housing material | PA |
|---|---|
| Flammability rating according to UL 94 | V0 |
| Color | black |
| Standards for cearances and creepage distances | DIN VDE 0110-1 |
| IEC 60664-1 | |
| Overvoltage category | II |
| Pollution degree | 2 |
| Mounting type | Connection-specific intermediate plugging |
| Type | Attachment plug |
| Number of positions | 1 |
| Direction of action | Line-Shield/Earth Ground |
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| Maximum continuous voltage UC | 180 V DC |
| 130 V AC | |
| Maximum continuous voltage UC(wire-shield) | 180 V DC |
| Nominal current IN | 1.5 A (25 °C) |
| Operating effective current ICat UC | ≤ 1 µA |
| Nominal discharge current In(8/20) µs (Core-Shield) | 2.5 kA |
| Total surge current (8/20) µs | 2.5 kA |
| Nominal pulse current Ian (10/1000) µs (Core-Shield) | 120 A |
| Output voltage limitation at 1 kV/µs (Core-Shield) spike | ≤ 600 V |
| Output voltage limitation at 1 kV/µs (Core-Shield) static | ≤ 600 V |
| Residual voltage at In(conductor-shield) | ≤ 30 V |
| Voltage protection level Up(core-shield) | ≤ 700 V (C2 - 4 kV/2 kA) |
| Response time tA (Core-GND) | ≤ 100 ns |
| Input attenuation aE, asym. | 0.5 dB (≤ 2.4 GHz) |
| Cut-off frequency fg (3 dB), asym. (shield) in 75 Ohm system | > 3 GHz |
| Frequency range | 4.7 MHz ... 2.5 GHz |
| Capacity asymmetrical (shield) | typ. 10 pF |
| Impulse durability (conductor-shield) | C2 - 4 kV/2 kA |
| C3 - 100 A | |
| D1 (500 A) | |
| Alternating current carrying capacity (conductor-shield) | 5 A - 1 s |
Connection data
| Connection method | F connector |
|---|---|
| Connection type IN | F connector, female |
| Connection type OUT | F connector, female |
Standards and Regulations
| Standards/regulations | IEC 61643-21 |
|---|---|
| EN 50083 - CLASS A |