View larger
CN-UB-280DC-SB 2818148 PHOENIX CONTACT Surge protection device
CN-UB-280DC-SB
2818148
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact Surge protection device part number CN-UB-280DC-SB is an electronic safety component integrated into industrial control loops and communication lines to divert high-energy voltage transients safely away from sensitive automation hardware. These protective modules safeguard continuous plant operations from lightning strikes and switching surges.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2818148
- Packing unit: 1 pc
- Catalog page: Page 475 (C-8-2013)
- GTIN: 4017918148379
- Weight per Piece (excluding packing): 145.800 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 25 mm
- Width: 25 mm
- Depth: 72 mm
- Ambient temperature (operation): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Degree of protection: IP55
- Housing material: Nickel-plated brass
- Overvoltage category: III
- Degree of pollution: 2
More info
▲Key Commercial Data
| Orderkey | 2818148 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 475 (C-8-2013) |
| GTIN | 4017918148379 |
| Weight per Piece (excluding packing) | 145.800 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 80 °C |
|---|---|
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Degree of protection | IP55 |
General
| Housing material | Nickel-plated brass |
|---|---|
| Overvoltage category | III |
| Degree of pollution | 2 |
| Mounting type | Connection-specific intermediate plugging |
| Type | Attachment plug |
| Direction of action | Line-Shield/Earth Ground |
Additional descriptions
| Note | To meet the discharge conditions for DC voltages, please note the following information: "The surge protective device should be used together with a transmitter unit, which shuts down in the event of a short-circuit." |
|---|
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| Maximum continuous voltage UC | 280 V DC |
| 195 V AC | |
| Rated current | 5 A (25 °C) |
| Operating effective current ICat UC | ≤ 1 µA |
| Nominal discharge current In(8/20) µs (line-earth) | 20 kA |
| Nominal discharge current In(8/20) µs (line-shield) | 20 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 2.5 kA |
| Pulse discharge current Iimp(10/350) µs (line-shield) | 2.5 kA |
| Total discharge current Itotal(8/20) µs | 20 kA |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 20 kA |
| Max. discharge current Imax(8/20) µs maximum (line-shield) | 20 kA |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 100 A |
| Nominal pulse current Ian (10/1000) µs (Core-Shield) | 100 A |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 900 V |
| Output voltage limitation at 1 kV/µs (line-shield) spike | ≤ 900 V |
| Voltage protection level Up(line-earth) | ≤ 900 V (C1 - 1 kV/500 A) |
| ≤ 1.1 kV (C2 - 10 kV / 5 kA) | |
| ≤ 1 kV (C3 - 25 A) | |
| Voltage protection level Up(line-shield) | ≤ 900 V (C1 - 1 kV/500 A) |
| ≤ 1.1 kV (C2 - 10 kV / 5 kA) | |
| ≤ 1 kV (C3 - 25 A) | |
| Response time tA | ≤ 100 ns |
| Input attenuation aE, asym. | typ. 0.1 dB (≤ 1.2 GHz / 50 Ω) |
| typ. 0.2 dB (≤ 2.2 GHz / 50 Ω) | |
| Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system | > 3 GHz |
| Standing wave ratio SWR in a 50 Ω system | typ. 1.1 (≤ 2 GHz) |
| Permissible HF power Pmaxat VSWR = xx (50 ohm system) | 700 W (VSWR = 1.1) |
| 200 W (VSWR = ∞) | |
| Capacity | typ. 1.5 pF |
| Surge protection fault message | none |
| Impulse durability (line-earth) | C1 - 1 kV/500 A |
| C2 - 10 kV/5 kA | |
| C3 - 100 A | |
| D1 - 2.5 kA | |
| Impulse durability (line-shield) | C1 - 1 kV/500 A |
| C2 - 10 kV/5 kA | |
| C3 - 100 A | |
| D1 - 2.5 kA |
Connection data
| Connection method | N connector 50 Ω |
|---|---|
| Connection method IN | N connector, male |
| Connection method OUT | N connector, female |
Standards and Regulations
| Standards/specifications | IEC 61643-21 2000 + A1:2008 |
|---|---|
| EN 61643-21 2001 + A1:2009 |