View larger
CN-UB-280DC-BB 2818850 PHOENIX CONTACT Surge protection device
CN-UB-280DC-BB
2818850
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Providing robust defense for automation loops, the Phoenix Contact CN-UB-280DC-BB surge protection device absorbs destructive electrical transients before they reach critical machinery. These units are deployed in harsh field environments to protect DC-powered automation gear from unexpected voltage surges. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2818850
- Packing unit: 1 pc
- Catalog page: Page 475 (C-8-2013)
- GTIN: 4017918164027
- Weight per Piece (excluding packing): 131.450 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 25 mm
- Width: 25 mm
- Depth: 67 mm
- Ambient temperature (operation): -40 °C ... 80 °C
- Altitude: ≤ 2000 m (amsl (above mean sea level))
- Degree of protection: IP55
- Housing material: Nickel-plated brass
- Overvoltage category: III
- Degree of pollution: 2
More info
▲Key Commercial Data
| Orderkey | 2818850 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 475 (C-8-2013) |
| GTIN | 4017918164027 |
| Weight per Piece (excluding packing) | 131.450 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -40 °C ... 80 °C |
|---|---|
| Altitude | ≤ 2000 m (amsl (above mean sea level)) |
| Degree of protection | IP55 |
General
| Housing material | Nickel-plated brass |
|---|---|
| Overvoltage category | III |
| Degree of pollution | 2 |
| Mounting type | Connection-specific intermediate plugging |
| Type | Attachment plug |
| Direction of action | Line-Shield/Earth Ground |
Additional descriptions
| Note | To meet the discharge conditions for DC voltages, please note the following information: "The surge protective device should be used together with a transmitter unit, which shuts down in the event of a short-circuit." |
|---|
Protective circuit
| IEC test classification | C1 |
|---|---|
| C2 | |
| C3 | |
| D1 | |
| Maximum continuous voltage UC | 280 V DC |
| 195 V AC | |
| Rated current | 5 A (25 °C) |
| Operating effective current ICat UC | ≤ 1 µA |
| Nominal discharge current In(8/20) µs (line-earth) | 20 kA |
| Nominal discharge current In(8/20) µs (line-shield) | 20 kA |
| Pulse discharge current Iimp(10/350) µs (line-earth) | 2.5 kA |
| Pulse discharge current Iimp(10/350) µs (line-shield) | 2.5 kA |
| Total discharge current Itotal(8/20) µs | 20 kA |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 20 kA |
| Max. discharge current Imax(8/20) µs maximum (line-shield) | 20 kA |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 100 A |
| Nominal pulse current Ian (10/1000) µs (Core-Shield) | 100 A |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 900 V |
| Output voltage limitation at 1 kV/µs (line-shield) spike | ≤ 900 V |
| Voltage protection level Up(line-earth) | ≤ 900 V (C1 - 1 kV/500 A) |
| ≤ 1.1 kV (C2 - 10 kV / 5 kA) | |
| ≤ 1 kV (C3 - 25 A) | |
| Voltage protection level Up(line-shield) | ≤ 900 V (C1 - 1 kV/500 A) |
| ≤ 1.1 kV (C2 - 10 kV / 5 kA) | |
| ≤ 1 kV (C3 - 25 A) | |
| Response time tA | ≤ 100 ns |
| Input attenuation aE, asym. | typ. 0.1 dB (≤ 1.2 GHz / 50 Ω) |
| typ. 0.2 dB (≤ 2.2 GHz / 50 Ω) | |
| Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system | > 3 GHz |
| Standing wave ratio SWR in a 50 Ω system | typ. 1.1 (≤ 2 GHz) |
| Permissible HF power Pmaxat VSWR = xx (50 ohm system) | 700 W (VSWR = 1.1) |
| 200 W (VSWR = ∞) | |
| Capacity | typ. 1.5 pF |
| Surge protection fault message | none |
| Impulse durability (line-earth) | C1 - 1 kV/500 A |
| C2 - 10 kV/5 kA | |
| C3 - 100 A | |
| D1 - 2.5 kA | |
| Impulse durability (line-shield) | C1 - 1 kV/500 A |
| C2 - 10 kV/5 kA | |
| C3 - 100 A | |
| D1 - 2.5 kA |
Connection data
| Connection method | N connector 50 Ω |
|---|---|
| Connection method IN | N connector, female |
| Connection method OUT | N connector, female |
Standards and Regulations
| Standards/specifications | IEC 61643-21 2000 + A1:2008 |
|---|---|
| EN 61643-21 2001 + A1:2009 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |