View larger
DT-UFB-V24/S-9-SB 2803069 PHOENIX CONTACT Surge protection device
DT-UFB-V24/S-9-SB
2803069
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact DT-UFB-V24/S-9-SB surge protection device is built to protect high-speed V24 serial interface connections from damaging transient voltage spikes. Interface-specific surge protectors are commonly mounted in industrial control enclosures to prevent communication link failures caused by electrical noise and surges. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2803069
- Packing unit: 1 pc
- Catalog page: Page 144 (C-4-2017)
- GTIN: 4046356312974
- Weight per Piece (excluding packing): 300.550 g
- Custom tariff number: 85363010
- Country of origin: DE (Germany)
- Height: 102 mm
- Width: 25 mm
- Depth: 63.5 mm
- Ambient temperature (operation): -40 °C ... 85 °C
- Degree of protection: IP20
- Housing material: Zinc die-cast
- Color: silver/black
- Standards for cearances and creepage distances: IEC 60664-1
- Mounting type: Connection-specific attachment plug and DIN rail, 35 mm
More info
▲Key Commercial Data
| Orderkey | 2803069 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 144 (C-4-2017) |
| GTIN | 4046356312974 |
| Weight per Piece (excluding packing) | 300.550 g |
| Custom tariff number | 85363010 |
| Country of origin | DE (Germany) |
General
| Housing material | Zinc die-cast |
|---|---|
| Color | silver/black |
| Standards for cearances and creepage distances | IEC 60664-1 |
| VDE 0110-1 | |
| Mounting type | Connection-specific attachment plug and DIN rail, 35 mm |
| Type | Attachment plug for DIN rail mounting |
| Number of positions | 9 |
| Direction of action | Line-Line & Line-Signal Ground/Shield & Signal Ground/Shield-Earth Ground |
Protective circuit
| IEC test classification | B2 |
|---|---|
| C1 | |
| C2 | |
| C3 | |
| VDE requirement class | B2 |
| C1 | |
| C2 | |
| C3 | |
| Maximum continuous voltage UC | 15 V DC |
| 10 V AC | |
| Rated current | ≤ 1 A (25 °C) |
| Operating effective current ICat UC | ≤ 5 µA (per wire) |
| Residual current IPE | ≤ 1 µA |
| Nominal discharge current In(8/20) µs (line-line) | ≤ 250 A |
| Nominal discharge current In(8/20) µs (line-earth) | ≤ 250 A |
| Nominal discharge current In(8/20) µs (core-signal ground) | ≤ 250 A |
| Nominal discharge current In(8/20) µs (signalground-earth) | ≤ 5 kA |
| Total discharge current Itotal(8/20) µs | 5 kA |
| Nominal pulse current Ian (10/1000) µs (line-line) | 50 A |
| Nominal pulse current Ian (10/1000) µs (line-earth) | 50 A |
| Nominal pulse current Ian (10/1000) µs (line-signalground) | 50 A |
| Nominal pulse current Ian (10/700) µs (line-line) | 50 A |
| Nominal pulse current Ian (10/700) µs (line-earth) | 50 A |
| Nominal pulse current Ian (10/700) µs (line-signalground) | 50 A |
| Output voltage limitation at 1 kV/µs (line-line) static | ≤ 50 V |
| Output voltage limitation at 1 kV/µs (line-signalground) static | ≤ 30 V |
| Residual voltage at In(line-line) | ≤ 55 V |
| Residual voltage at In(line-signalground) | ≤ 30 V |
| Voltage protection level Up(line-line) | ≤ 55 V (C1 - 250 A) |
| ≤ 55 V (B2 - 25 A) | |
| Voltage protection level Up(line-earth) | ≤ 450 V (C1 - 250 A) |
| ≤ 400 V (B2 - 25 A) | |
| Voltage protection level Up(line-signalground) | ≤ 30 V (C1 - 250 A) |
| ≤ 30 V (B2 - 25 A) | |
| Response time tA(line-line) | ≤ 1 ns |
| Response time tA (line-signalground) | ≤ 1 ns |
| Response time tA(line-earth) | ≤ 100 ns |
| Response time tA (shield-earth) | ≤ 100 ns |
| Input attenuation aE, sym. | typ. 0.3 dB (≤ 700 kHz / 100 Ω) |
| typ. 0.3 dB (≤ 700 kHz / 150 Ω) | |
| Input attenuation aE, asym. | typ. 0.3 dB (≤ 400 kHz / 100 Ω) |
| typ. 0.3 dB (≤ 400 kHz / 150 Ω) | |
| Cut-off frequency fg (3 dB), sym. in 100 Ohm system | typ. 2.5 MHz |
| Cut-off frequency fg (3 dB), sym. in 150 Ohm system | typ. 2.5 MHz |
| Cut-off frequency fg (3 dB), asym. (GND) in 100 Ohm system | typ. 1.3 MHz |
| Cut-off frequency fg (3 dB), asym. (GND) in 150 Ohm system | typ. 1.3 MHz |
| Capacity (line-line) | typ. 1 nF (f=1 MHz / VR= 0 V) |
| Capacity (line-signalground) | typ. 2 nF (f=1 MHz / VR= 0 V) |
| Surge protection fault message | none |
| Impulse durability (line-line) | B2 - 1 kV / 25 A |
| C1 - 500 V / 250 A | |
| Impulse durability (line-signalground) | B2 - 1 kV/25 A |
| C1 - 500 V/250 A | |
| Impulse durability (signalground-earth) | B2 - 4 kV / 100 A |
| C1 - 100 V / 500 A | |
| C2 - 10 kV/5 kA | |
| Alternating current carrying capacity (signalground-earth) | 5 A - 1 s |
Connection data
| Connection method | D-SUB-9 |
|---|---|
| Connection method IN | D-SUB-9 plug |
| Connection method OUT | D-SUB-9 socket |
Standards and Regulations
| Standards/regulations | IEC 61643-21 |
|---|---|
| Standards/specifications | DIN EN 61643-21 2002 |
| IEC 61643-21 2000 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |