View larger
CN-UB-70DC-6-SB 2803153 PHOENIX CONTACT Surge protection device
CN-UB-70DC-6-SB
2803153
PHOENIX CONTACT
1 Pcs.
Automation > Surge protection device for data networks/MCR-technology
Trabtech (TT)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for harsh environments, the Phoenix Contact CN-UB-70DC-6-SB is a specialized surge protection device built to maintain the integrity of coaxial or data communication systems. Such protective modules are essential in industrial automation networks where prolonged exposure to moisture, dust, and electrical transients threatens communication reliability. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Orderkey: 2803153
- Packing unit: 1 pc
- Note: Made to Order (non-returnable)
- Catalog page: Page 176 (C-4-2017)
- GTIN: 4046356293204
- Weight per Piece (excluding packing): 82.900 g
- Custom tariff number: 85363010
- Country of origin: US (United States)
- Height: 24 mm
- Width: 24 mm
- Depth: 50 mm
- Ambient temperature (operation): -40 °C ... 90 °C
- Degree of protection: IP68
- Housing material: Brass (CuZn)
- Color: nickel
- Standards for cearances and creepage distances: DIN VDE 0110-1
More info
▲Key Commercial Data
| Orderkey | 2803153 |
|---|---|
| Packing unit | 1 pc |
| Note | Made to Order (non-returnable) |
| Catalog page | Page 176 (C-4-2017) |
| GTIN | 4046356293204 |
| Weight per Piece (excluding packing) | 82.900 g |
| Custom tariff number | 85363010 |
| Country of origin | US (United States) |
General
| Housing material | Brass (CuZn) |
|---|---|
| Color | nickel |
| Standards for cearances and creepage distances | DIN VDE 0110-1 |
| IEC 60664-1 | |
| Mounting type | Connection-specific intermediate plugging |
| Type | Attachment plug |
| Direction of action | Line-Shield/Earth Ground |
Additional descriptions
| Note | To meet the discharge conditions for DC voltages, please note the following information: "The surge protective device should be used together with a transmitter unit, which shuts down in the event of a short-circuit." |
|---|
Protective circuit
| IEC test classification | C2 |
|---|---|
| C3 | |
| D1 | |
| VDE requirement class | C2 |
| C3 | |
| D1 | |
| Maximum continuous voltage UC | 70 V DC |
| 50 V AC | |
| Maximum continuous voltage UC(line-earth) | 70 V DC |
| 50 V AC | |
| Rated current | 10 A |
| Operating effective current ICat UC | ≤ 1 µA |
| Nominal discharge current In(8/20) µs | 5 kA |
| Nominal discharge current In(8/20) µs (line-earth) | 5 kA |
| Nominal discharge current In(8/20) µs (line-shield) | 5 kA |
| Total discharge current Itotal(8/20) µs | 5 kA |
| Max. discharge current Imax(8/20) µs maximum (line-earth) | 10 kA |
| Max. discharge current Imax(8/20) µs maximum (line-shield) | 10 kA |
| Nominal pulse current Ian (10/1000) µs (Core-Shield) | 100 A |
| Impulse discharge current (10/350) µs, peak value limp | 1 kA |
| Output voltage limitation at 1 kV/µs (line-earth) spike | ≤ 650 V |
| Output voltage limitation at 1 kV/µs (line-shield) spike | ≤ 650 V |
| Output voltage limitation at 1 kV/µs (line-earth) static | ≤ 650 V |
| Output voltage limitation at 1 kV/µs (line-shield) static | ≤ 650 V |
| Voltage protection level Up(line-earth) | ≤ 800 V (C2 - 4 kV / 2 kA) |
| ≤ 1 kV (C2 - 10 kV / 5 kA) | |
| Voltage protection level Up(line-shield) | ≤ 800 V (C2 - 4 kV / 2 kA) |
| ≤ 1 kV (C2 - 10 kV / 5 kA) | |
| Response time tA(line-earth) | ≤ 100 ns |
| Response time tA (line-shield) | ≤ 100 ns |
| Input attenuation aE, asym. | 0.1 dB (≤ 6 GHz) |
| Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system | > 6 GHz |
| Frequency range | 0 Hz ... 6 GHz |
| Standing wave ratio SWR in a 50 Ω system | typ. 1.15 (≤ 6 GHz) |
| Permissible HF power Pmaxat VSWR = xx (50 ohm system) | 30 W (VSWR = 1.15) |
| Capacity (line-earth) | typ. 1.5 pF |
| Capacity asymmetrical (shield) | typ. 1.5 pF |
| Surge protection fault message | none |
| Impulse durability (line-earth) | C2 - 10 kV/5 kA |
| C3 - 100 A | |
| D1 - 1 kA | |
| Impulse durability (line-shield) | C2 - 10 kV/5 kA |
| C3 - 100 A | |
| D1 - 1 kA | |
| Alternating current carrying capacity (line-shield) | 5 A - 1 s |
Connection data
| Connection method | N connector 50 Ω |
|---|---|
| Connection method IN | N connector, male |
| Connection method OUT | N connector, female |