Built as a Phoenix Contact FLK 14/16/EZ-DR/HF/ 200/S7 cable, this assembled halogen-free round cable links programmable logic controllers directly to peripheral devices. System cables are widely deployed in modern control architectures to transmit low-voltage control signals securely between automation modules while protecting against environmental wear in fixed installations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: System cable
- Data management status Article revision: 04
- Ambient conditions Degree of protection: IP00
- Degree of protection (Installation location): ≥ IP54 (Installation location)
- Ambient temperature (operation): -40 °C ... 70 °C (fixed installation)
- Ambient temperature (storage/transport): -40 °C ... 80 °C
- Altitude: ≤ 2000 m
- Operating voltage (AC): ≤ 30 V AC
- Operating voltage (DC): ≤ 60 V DC
- Nominal operating mode: 100% operating factor
- Current (Per path, 50°C): ≤ 1 A (Uncoiled, see derating)
- Current (Per path, 70°C): ≤ 0.6 A (Uncoiled, see derating)
- Cable length: 2 m
- Number of positions: 14
- Shielded: no
- Conductor type: Assembled, halogen-free round cable
More info
▲| Product type | System cable |
| Data management status | |
| Article revision | 04 |
| Ambient conditions | |
| Degree of protection | IP00 |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| -10 °C ... 70 °C (flexible installation) | |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Nominal operating mode | 100% operating factor |
| Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
| Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Cable length | 2 m |
| Number of positions | 14 |
| Shielded | no |
| Conductor type | Assembled, halogen-free round cable |
| Conductor structure signal line | 7x 0.16 mm |
| AWG signal line | 26 |
| Conductor cross section | 14x 0.14 mm² |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| External cable diameter | 5.80 mm ±0.4 mm |
| Outer sheath, material | halogen-free (type 2) |
| External sheath, color | gray |
| Conductor material | Tin-plated Cu litz wires |
| Cable resistance | ≤ 145 Ω/km (20 °C) |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Smallest bending radius, fixed installation | 50 mm |
| Smallest bending radius, movable installation | 93 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Halogen-free | yes |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| VDE 0842, Part 332-1-2 (raw cable) | |
| IEC 60332-3-22 (raw cable) | |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Cable type | Cable for one module |
| Color code | |
| white | IDC/FLK16 (1) = IDC/FLK14 (10) |
| violet | IDC/FLK16 (2) = IDC/FLK14 (8) |
| white-brown | IDC/FLK16 (3) = IDC/FLK14 (12) |
| blue | IDC/FLK16 (4) = IDC/FLK14 (7) |
| white-orange | IDC/FLK16 (5) = IDC/FLK14 (14) |
| green | IDC/FLK16 (6) = IDC/FLK14 (6) |
| yellow | IDC/FLK16 (8) = IDC/FLK14 (5) |
| gray | IDC/FLK16 (9) = IDC/FLK14 (9) |
| orange | IDC/FLK16 (10) = IDC/FLK14 (4) |
| white-black | IDC/FLK16 (11) = IDC/FLK14 (11) |
| red | IDC/FLK16 (12) = IDC/FLK14 (3) |
| white-red | IDC/FLK16 (13) = IDC/FLK14 (13) |
| brown | IDC/FLK16 (14) = IDC/FLK14 (2) |
| black | IDC/FLK16 (16) = IDC/FLK14 (1) |
| Connection 1 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 1 |
| Number of positions | 16 |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Connection 2 | |
| Connection in acc. with standard | based on IEC 60603-13 |
| Connection method | IDC/FLK socket strip |
| Number of connections | 1 |
| Number of positions | 14 |
| Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |