Network cable Ready-made Ethernet cable, CAT5e, shielded, 2 pairs, flexible AWG 26 (7 wires), RAL 5021 (aqua blue), M12 connector in RJ45/IP20 connector, Line, length 6 m Assembled Ethernet cable, CAT5e, shielded, 2-pair, 26 AWG stranded (7-wire), RAL 5021 (water blue), M12 plug to RJ45 plug/IP20, line, length: 6 m

Automation > Sensor-actuator patch cord
Industrial Field Connectivity (IFC)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Engineered for high-integrity industrial Ethernet networks, this Phoenix Contact NBC-M12MSD/ 6,0-93E/R4AC network cable links controllers and machinery safely. It guarantees stable communication speeds across automated industrial facilities.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Data cable preassembled
  • Sensor type: Ethernet
  • Number of positions: 4
  • No. of cable outlets: 1
  • Shielded: yes
  • Insulation characteristics Overvoltage category: I
  • Degree of pollution: 3
  • Bus system: Ethernet
  • Signal type/category: Ethernet CAT5 (IEC 11801:2002)
  • Nominal voltage U N: 48 V AC
  • Transmission medium: Copper
  • Transmission characteristics (category): CAT5 (IEC 11801:2002)
  • Mechanical data Insertion/withdrawal cycles: ≥ 100
  • Flammability rating according to UL 94: V2
  • Connection 1 Type: Plug straight M12
  • Number of positions: 4 (4)

More info

▲
Technical data

Product properties
Product typeData cable preassembled
Sensor typeEthernet
Number of positions4
No. of cable outlets1
Shieldedyes
Insulation characteristics
Overvoltage categoryI
Degree of pollution3

Interfaces
Bus systemEthernet
Signal type/categoryEthernet CAT5 (IEC 11801:2002)

Electrical properties
Nominal voltage UN48 V AC
60 V DC
Transmission mediumCopper
Transmission characteristics (category)CAT5 (IEC 11801:2002)

Mechanical properties
Mechanical data
Insertion/withdrawal cycles≥ 100

Material specifications
Flammability rating according to UL 94V2

Connector
Connection 1
TypePlug straight M12
Number of positions4 (4)
Shieldedyes
MaterialCuZn (Contact)
Ni/Au (Contact surface)
TPU GF (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip body)
Zinc die-cast, nickel-plated (Screw connection)
Connection 2
TypePlug straight RJ45
Number of positions4 (8)
Shieldedyes
MaterialCuSn (Contact)
Ni/Au (Contact surface)
PC (Contact carriers)
PA (Housing)

Cable/line
Cable length6 m
Ethernet flexible CAT5, 2-pair [93E]
Dimensional drawing
Cable weight42 kg/km
UL AWM Style20963 (80°C/30 V)
Wiring standards/regulationsElectrical requirements EN 50288-2-2
Number of positions4
Shieldedyes
Cable typeEthernet flexible CAT5, 2-pair [93E]
Conductor structure2x2xAWG26/7, SF/UTP
Signal runtime5.3 ns/m
Conductor structure signal line7x 0.16 mm
AWG signal line26
Conductor cross section2x 2x 0.14 mm²
Wire diameter incl. insulation0.98 mm
External cable diameter6.40 mm ±0.2 mm
Outer sheath, materialPUR
External sheath, colorwater blue RAL 5021
Conductor materialBare Cu litz wires
Material wire insulationFoamed PE
Single wire, colorwhite/orange-orange, white/green-green
Thickness, outer sheath1.20 mm
Twisted pairs2 cores to the pair
Overall twistTwo pairs with two fillers to the core
Optical shield covering70 %
Insulation resistance≥ 500 MΩ*km
Coupling resistance≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance≤ 290.00 Ω/km
Wave impedance100 Ω ±5 Ω (at 100 MHz)
Cable capacityapprox. 45 nF/km (at 1 kHz)
Nominal voltage, cable≤ 100 V (Peak value, not for high-power applications)
Test voltage Core/Core700 V (50 Hz, 1 min.)
Test voltage Core/Shield700.00 V (50 Hz, 1 min.)
Current carrying capacity of cable2.00 A (according to DIN VDE 0891-1)
Minimum bending radius, fixed installation4 x D
Minimum bending radius, flexible installation8 x D
Smallest bending radius, fixed installation26 mm
Smallest bending radius, movable installation52 mm
Tensile strength≤ 80 N
Near end crosstalk attenuation (NEXT)65.3 dB (with 1 MHz)
56.3 dB (at 4 МHz)
50.3 dB (at 10 MHz)
47.2 dB (at 16 MHz)
45.8 dB (at 20 МHz)
42.9 dB (at 31.25 МHz)
38.4 dB (at 62.5 МHz)
35.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT)62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20 МHz)
39.9 dB (at 31.25 МHz)
35.4 dB (at 62.5 МHz)
32.3 dB (at 100 MHz)
Return attenuation (RL)23 dB (at 4 МHz)
24.1 dB (at 8 МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20 МHz)
23.6 dB (at 31.25 МHz)
21.5 dB (at 62.5 МHz)
20.1 dB (at 100 MHz)
Shield attenuation3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20 МHz)
17.1 dB (at 31.25 МHz)
24.8 dB (at 62.5 МHz)
32 dB (at 100 MHz)
Halogen-freeaccording to IEC 60754-1
Flame resistanceaccording to IEC 60332-1-2
in acc. to UL VW1
in accordance with UN ECE-R 118.03
Resistance to oilin accordance with EN 60811-2-1
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (Cable, flexible installation)
Ambient temperature (installation)-20 °C ... 80 °C

Environmental and real-life conditions
Ambient conditions
Degree of protectionIP67/IP20
Ambient temperature (operation)-25 °C ... 60 °C (cable, fixed installation)
-5 °C ... 50 °C (Cable, flexible installation)