A FLKM-KS40/AO16/YCS 2314260 PHOENIX CONTACT Passive module routes specialized system signals between pre-assembled controller cabling and standard terminal blocks. Industrial engineers rely on these interface blocks to maintain signal integrity and accelerate commissioning processes in large automation networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Interface module
- No. of channels: 16
- Data management status Article revision: 05
- Overvoltage category: II
- Pollution degree: 2
- Operating voltage (DC): ≤ 30 V DC
- Current (per branch): ≤ 0.1 A
- Rated surge voltage: 0.5 kV (1.2/50 μs)
- Supported controller YOKOGAWA STARDOM Suitable I/O card: NFAI543
- Connection 1 (control level) Connection method: Yokogawa KS-compatible
- Number of connections: 2
- Number of positions: 40
- Note: Usable system cables: Phoenix Contact YUC40, Yokogawa KS1
- Tightening torque: 0.5 Nm
- Pitch: 2.54 mm
- Connection 2 (field level) Connection method: Screw connection
More info
▲| Product type | Interface module |
| No. of channels | 16 |
| Data management status | |
| Article revision | 05 |
| Insulation characteristics: Air clearances and creepage distances | |
| Insulation | Functional insulation |
| Overvoltage category | II |
| Pollution degree | 2 |
| Operating voltage (DC) | ≤ 30 V DC |
| Current (per branch) | ≤ 0.1 A |
| Air clearances and creepage distances | |
| Rated insulation voltage | 50 V |
| Rated surge voltage | 0.5 kV (1.2/50 μs) |
| Supported controller YOKOGAWA CS3000 CentumVP | |
| Suitable I/O card | AAI543 |
| Supported controller YOKOGAWA STARDOM | |
| Suitable I/O card | NFAI543 |
| Connection 1 (control level) | |
| Connection method | Yokogawa KS-compatible |
| Number of connections | 2 |
| Number of positions | 40 |
| Note | Usable system cables: Phoenix Contact YUC40, Yokogawa KS1 |
| Tightening torque | 0.5 Nm |
| Pitch | 2.54 mm |
| Connection 2 (field level) | |
| Connection method | Screw connection |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Number of positions | 48 |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Conductor cross-section rigid (2 conductors with same cross section) | 0.2 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| 0.25 mm² ... 1.5 mm² (Ferrule without plastic sleeve) | |
| 0.25 mm² ... 2.5 mm² (Ferrule with plastic sleeve) | |
| Conductor cross section flexible (2 conductors with same cross section) | 0.2 mm² ... 1.5 mm² |
| 0.25 mm² ... 0.75 mm² (Ferrule without plastic sleeve) | |
| 0.5 mm² ... 0.5 mm² (TWIN ferrule with plastic sleeve) | |
| Conductor cross section AWG | 24 ... 12 |
| Tightening torque | 0.5 Nm ... 0.6 Nm |
| Pitch | 5.08 mm |
| Connection 3 (HART connector) | |
| Connection method | HART connector |
| Number of connections | 1 |
| Number of positions | 26 |
| Pitch | 1.27 mm |
| Status display present | No |
| Item dimensions | |
| Width | 107.5 mm |
| Height | 125.4 mm |
| Depth | 65.9 mm |
| Ambient conditions | |
| Degree of protection (Module) | IP00 |
| Degree of protection (Installation location) | ≤ IP54 |
| Ambient temperature (operation) | -20 °C ... 50 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Altitude | ≤ 2000 m |
| UKCA | |
| Certificate | UKCA-compliant |
| Air clearances and creepage distances | |
| Standards/regulations | EN IEC 60664-1 |
| Mounting type | DIN rail mounting |
| Mounting position | any |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |