View larger
AGK PT 4X6/M10 GNYE 1083238 PHOENIX CONTACT Pick-off terminal block, nom. voltage: 1000 V, nominal current: ..
AGK PT 4X6/M10 GNYE
1083238
PHOENIX CONTACT
10 Pcs.
Connectors > Terminal block connector
Modular TBs
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
AGK PT 4X6/M10 GNYE 1083238 PHOENIX CONTACT Pick-off terminal block, nom. voltage: 1000 V, nominal current: .. is an auxiliary pick-off terminal block utilized in power distribution systems to tap high-capacity electrical lines safely and reliably. These components enable technicians to branch off auxiliary circuits or monitor system voltages without interrupting the primary main current feed. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Connectable conductor cross section solid-core (EF007337): 0.5 mm²
- Rated current In (EF008250): 41 A
- Rated voltage (EF000228): 1000 V
- Number of clamp positions per level (EF002660): 5
- Suitable for conductor material (EF012572): Aluminium/copper
- Width (EF000008): 31.05 mm
- Height (EF000040): 57.546666 mm
- Depth (EF000049): 35.63009 mm
- Closing plate required (EF002525): No
- Colour (EF000007): Green/yellow
- Internally connected stages (EF002661): Yes
More info
▲Key Commercial Data
| Orderkey | 1083238 |
|---|---|
| Packing unit | 1 |
| Catalog page | Page 119 (C-1-2019) |
| GTIN | 4055626816753 |
| Custom tariff number | 85369010 |
General
| Number of levels | 1 |
|---|---|
| Number of connections | 5 |
| Nominal cross section | 6 mm² |
| Color | green-yellow |
| Insulating material | PA |
| Flammability rating according to UL 94 | V0 |
| Rated surge voltage | 8 kV |
| Overvoltage category | III |
| Insulating material group | I |
| Maximum load current | 57 A |
| Maximum total current | 106 A (Bolt connection) |
| Nominal current IN | 41 A |
| Nominal voltage UN | 1000 V |
| Nominal current IN | 41 A |
| Open side panel | No |
Connection data
| Connection | 1 level |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 10 mm ... 12 mm |
| Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section solid min. | 0.5 mm² |
| Conductor cross section solid max. | 10 mm² |
| Conductor cross section AWG min. | 20 |
| Conductor cross section AWG max. | 8 |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 6 mm² |
| Min. AWG conductor cross section, flexible | 20 |
| Max. AWG conductor cross section, flexible | 10 |
| Conductor cross section flexible, with ferrule without plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve max. | 6 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve min. | 0.5 mm² |
| Conductor cross section flexible, with ferrule with plastic sleeve max. | 6 mm² |
| Internal cylindrical gage | A5 |
| Connection | 1 level |
| Note | Connection bolts |
| Connection method | Bolt connection |
| Screw thread | M10 |
| Connection in acc. with standard | IEC 60947-7-1 |
| Tightening torque, min | 10 Nm |
| Tightening torque max | 20 Nm |
| Conductor cross section flexible min. | 6 mm² |
| Conductor cross section flexible max. | 120 mm² |
| Min. AWG conductor cross section, flexible | 10 |
| Max. AWG conductor cross section, flexible | 250 kcmil |
| Hole diameter, min. | 10.4 mm |
| Cable lug width, max. | 32 mm |
| Bolt diameter | 10 mm |
| Screw thread | M10 |
Standards and Regulations
| Connection in acc. with standard | IEC 60947-7-1 |
|---|---|
| IEC 60947-7-1 | |
| Flammability rating according to UL 94 | V0 |
Classifications
eCl@ss
| eCl@ss 4.0 | 27141131 |
|---|---|
| eCl@ss 4.1 | 27141131 |
| eCl@ss 5.0 | 27141131 |
| eCl@ss 5.1 | 27141120 |
| eCl@ss 6.0 | 27141100 |
| eCl@ss 7.0 | 27141151 |
| eCl@ss 8.0 | 27141120 |
| eCl@ss 9.0 | 27141120 |
ETIM
| ETIM 2.0 | EC000897 |
|---|---|
| ETIM 3.0 | EC000897 |
| ETIM 4.0 | EC000897 |
| ETIM 5.0 | EC000897 |
| ETIM 6.0 | EC000897 |
| ETIM 7.0 | EC000897 |
UNSPSC
| UNSPSC 6.01 | 30211811 |
|---|---|
| UNSPSC 7.0901 | 39121410 |
| UNSPSC 11 | 39121410 |
| UNSPSC 12.01 | 39121410 |
| UNSPSC 13.2 | 39121402 |
| UNSPSC 18.0 | 39121410 |
| UNSPSC 19.0 | 39121410 |
| UNSPSC 20.0 | 39121410 |
| UNSPSC 21.0 | 39121410 |