View larger
PLC-OPT-110DC/110DC/3RW 2900396 PHOENIX CONTACT Solid-state relay module
PLC-OPT-110DC/110DC/3RW
2900396
PHOENIX CONTACT
1 Pcs.
Automation > Optocoupler
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for demanding industrial applications, the PLC-OPT-110DC/110DC/3RW 2900396 PHOENIX CONTACT Solid-state relay module delivers reliable electronic switching with high operational endurance. Solid-state relay modules provide contactless switching for DC control circuits, reducing maintenance requirements and preventing contact wear in high-cycle processes. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Input voltage (EF003840): 77 V
- Type of voltage (input voltage) (EF003033): DC
- Output voltage (EF003933): 12 V
- Type of output voltage (EF008222): DC
- Rated operation current Ie (EF001443): 3 A
- Type of digital output (EF003601): Electronic
- With LED indication (EF005950): Yes
More info
▲Key Commercial Data
| Orderkey | 2900396 |
|---|---|
| Packing unit | 10 pc |
| Catalog page | Page 415 (C-5-2017) |
| GTIN | 4046356506953 |
| Weight per Piece (excluding packing) | 35.770 g |
| Custom tariff number | 85364900 |
| Country of origin | DE (Germany) |
Note
| Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
|---|
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 70 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | IP20 |
Input data
| Nominal input voltage UN | 110 V DC |
|---|---|
| Input voltage range in reference to UN | 0.7 ... 1.25 (t < 1 s = 0.6 ... 1.4 x UN) |
| Input voltage range | 77 V DC ... 137.5 V DC |
| Switching threshold "0" signal in reference to UN | < 0.3 |
| Switching threshold "1" signal in reference to UN | > 0.6 |
| Typical input current at UN | 5.5 mA |
| Typical response time | 400 µs |
| Typical turn-off time | 200 µs |
| Operating voltage display | Yellow LED |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Series polarity protection diode |
| Surge voltage protection | > 150 V |
| Transmission frequency | 300 Hz |
| Power dissipation for nominal condition | 0.6 W |
Output data
| Output nominal voltage | 110 V DC |
|---|---|
| Output voltage range | 12 V DC ... 140 V DC (t < 1 s = 1.40 x UN) |
| Limiting continuous current | 3 A (see derating curve) |
| Surge voltage protection | > 150 V |
| Voltage drop at max. limiting continuous current | < 150 mV |
| Output circuit | 2-wire, floating |
| Type of protection | Reverse polarity protection |
| Surge protection | |
| Protective circuit/component | Parallel polarity protection diode |
Connection data 1
| Connection name | Input side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
Connection data 2
| Connection name | Output side |
|---|---|
| Connection method | Push-in connection |
| Stripping length | 8 mm |
| Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| Conductor cross section AWG | 26 ... 14 |
General
| Test voltage input/output | 2.5 kVrms |
|---|---|
| Mounting position | any |
| Assembly instructions | In rows with zero spacing |
| Operating mode | 100% operating factor |
| Flammability rating according to UL 94 | V0 |
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Degree of pollution | 2 |
| Overvoltage category | III |
Standards and Regulations
| Connection in acc. with standard | CUL |
|---|---|
| Designation | Air clearances and creepage distances between the power circuits |
| Standards/regulations | IEC 60664 |
| EN 50178 | |
| Rated insulation voltage | 160 V DC |
| Rated surge voltage | 4 kV |
| Insulation | Basic insulation |
| Degree of pollution | 2 |
| Overvoltage category | III |
| Flammability rating according to UL 94 | V0 |
Environmental Product Compliance
| REACh SVHC | Lead 7439-92-1 |
|---|---|
| China RoHS | Environmentally Friendly Use Period = 50 |
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |