PLC-BSC- 24UC/ 1/ACT 2982799 PHOENIX CONTACT Relay base
PLC-BSC-24UC/ 1/ACT
2982799
PHOENIX CONTACT
1 Pcs.
Automation > Relay socket
Industrial Relays
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The PLC-BSC- 24UC/ 1/ACT 2982799 PHOENIX CONTACT Relay base serves as a secure socket interface designed to hold control relays and streamline actuator wiring in automated systems. Relay sockets facilitate rapid component replacement and maintain organized signal distribution within industrial control panels. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product type: Relay socket
- Product family: PLC-INTERFACE
- Application: Output function
- Operating mode: 100% operating factor
- Data management status Article revision: 06
- Insulation characteristics Pollution degree: 3
- Nominal input voltage U N: 24 V AC/DC
- Protective circuit: Bridge rectifier
- Relay assembly Rated control circuit supply voltage U S: 24 V AC/DC
- Voltage range with reference to U S: 0.8 ... 1.2
- Typical input current at U N: 15.6 mA (50 Hz)
- Typical response time: 5 ms
- Typical release time: 30 ms
- Operating voltage display: Yellow LED
More info
▲| Product type | Relay socket |
| Product family | PLC-INTERFACE |
| Application | Output function |
| Operating mode | 100% operating factor |
| Compatible components | Miniature relay, REL-MR-24DC/21, REL-MR-24DC/21AU; miniature optocoupler, OPT-24DC/24DC/2, OPT-24DC/48DC/100, OPT-24DC/230AC/1 |
| Data management status | |
| Article revision | 06 |
| Insulation characteristics | |
| Pollution degree | 3 |
| Nominal input voltage UN | 24 V AC/DC |
| The nominal voltage of the plug-on electromechanical relay or solid-state relay (see necessary accessories) deviates from the nominal input voltage of the base with integrated upstream circuit | |
| Protective circuit | Bridge rectifier |
| Nominal input voltage UN | 24 V AC/DC |
| The nominal voltage of the plug-on electromechanical relay or solid-state relay (see necessary accessories) deviates from the nominal input voltage of the base with integrated upstream circuit | |
| Relay assembly | |
| Rated control circuit supply voltage US | 24 V AC/DC |
| Voltage range with reference to US | 0.8 ... 1.2 |
| Typical input current at UN | 15.6 mA (50 Hz) |
| 8.5 mA (60 Hz) | |
| Typical response time | 5 ms |
| Typical release time | 30 ms |
| Operating voltage display | Yellow LED |
| Protective circuit | Bridge rectifier; Bridge rectifier |
| Optocoupler assembly | |
| Rated control circuit supply voltage US | 24 V AC/DC |
| Voltage range with reference to US | 0.8 ... 1.2 |
| Typical input current at UN | 15 mA (50 Hz) |
| 8.3 mA (60 Hz) | |
| Typical response time | 10 ms |
| Typical release time | 20 ms |
| Operating voltage display | Yellow LED |
| Protective circuit | Bridge rectifier; Bridge rectifier |
| Compatible components | Miniature relay, REL-MR-24DC/21, REL-MR-24DC/21AU; miniature optocoupler, OPT-24DC/24DC/2, OPT-24DC/48DC/100, OPT-24DC/230AC/1 |
| Maximum switching voltage | 33 V DC |
| Minimum switching voltage | 3 V DC |
| Limiting continuous current | 3 A (see derating curve) |
| Voltage drop at max. limiting continuous current | ≤ 150 mV |
| Output circuit | 2-conductor, floating |
| Protective circuit | Reverse polarity protection Parallel polarity protection diode |
| Surge protection | |
| Maximum switching voltage | 48 V DC |
| Minimum switching voltage | 3 V DC |
| Limiting continuous current | 100 mA |
| Voltage drop at max. limiting continuous current | ≤ 1 V |
| Output circuit | 2-conductor, floating |
| Protective circuit | Reverse polarity protection Parallel polarity protection diode |
| Surge protection | |
| Maximum switching voltage | 253 V AC |
| Minimum switching voltage | 24 V AC |
| Limiting continuous current | 0.75 A (see derating curve) |
| Voltage drop at max. limiting continuous current | ≤ 1 V |
| Output circuit | 2-conductor floating, zero voltage switch |
| Protective circuit | RCV circuit |
| Leakage current | ≤ 1 mA |
| Max. load value | 4.5 A2s (tp = 10 ms, at 25 °C) |
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section rigid | 0.14 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
| 0.2 mm² ... 2.5 mm² (Single ferrule) | |
| 2x 0.5 mm² ... 1.5 mm² (TWIN ferrule) | |
| Conductor cross section AWG | 26 ... 14 |
| Tightening torque | 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing)) |
| Width | 6.2 mm |
| Height | 80 mm |
| Depth | 94 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 (Housing) |
| Ambient conditions | |
| Ambient temperature (operation) | -20 °C ... 60 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| CE | |
| Certificate | CE-compliant |
| UKCA | |
| Certificate | UKCA-compliant |
| Shipbuilding approval | |
| Certificate | TAE0000196 |
| Corrosive gas test | |
| Identification | ISA-S71.04. G3 Harsh Group |
| EN 60068-2-60 | |
| DNV GL data | |
| Temperature | D |
| Humidity | A |
| Vibration | B/C |
| EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board |
| Electromagnetic compatibility | Conformance with EMC directive |
| Low Voltage Directive | Conformance with Low Voltage Directive |
| Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing |
| Mounting position | any |