PHOENIX CONTACT ELR H5-IES-SC-24DC/500AC-0,6 ELR H5-IES-SC- 24DC/500AC-0,6 2900582 PHOENIX CONTACT Hybrid motor starter for reversing 3~ AC motors up to .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

ELR H5-IES-SC- 24DC/500AC-0,6 2900582 PHOENIX CONTACT Hybrid motor starter for reversing 3~ AC motors up to ..

ELR H5-IES-SC-24DC/500AC-0,6

2900582

PHOENIX CONTACT

1 Pcs.

Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown, emergency stop function to SIL 3/PL e, and screw connection. Hybrid start controller for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with a control voltage of 24 V DC, adjustable overload circuit breaker, emergency stop function up to SIL 3/PL e and screw connection.

Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact hybrid motor starter (ELR H5-IES-SC-24DC/500AC-0,6) combines semiconductor and relay technologies to provide safe reversing control and overload monitoring for low-current AC motors. Space-saving hybrid starters are ideal for high-density control cabinet installations requiring frequent switching cycles.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Type of motor starter: Reversing starter
  • With short-circuit release: No
  • Rated control supply voltage DC: 19.2 V
  • Voltage type for actuating: DC
  • Rated operation current Ie: 0.6 A
  • Rated operation current at AC-3, 400 V: 0.6 A
  • Overload release current setting: 0.075 A
  • Temperature compensated overload protection: No
  • Release class: CLASS 10
  • Type of electrical connection of main circuit: Screw connection
  • Suitable for rail mounting: Yes
  • Number of command positions: 1
  • Suitable for emergency stop: Yes
  • External reset possible: Yes
  • Degree of protection (IP): IP20
  • Width: 22.5 mm

More info

▲

Input data

Input nameDevice supply
Rated control circuit supply voltage US24 V DC
Rated control supply current IS40 mA
Protective circuitProtection against polarity reversal Parallel polarity protection diode
Surge protection
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED
Input nameControl input right/left
Rated actuating voltage UC24 V DC
Rated actuating current IC5 mA
Switching threshold9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level< 5 V DC (For EMERGENCY STOP)
Protective circuitProtection against polarity reversal
Typical turn-off time< 30 ms

Output data load output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Load current range75 mA ... 600 mA (see to derating)
Trigger characteristic in acc. with IEC 60947Class 10A
Rated operating current at AC-510.6 A
Rated operating current at AC-53a0.6 A
Leakage current0 mA
Protective circuitSurge protection Varistor

Output data reply output

NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

General

Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionvertical (horizontal DIN rail, motor output below)
Assembly instructionsalignable, for spacing see derating
Operating mode100% operating factor
DesignationStandards/regulations
Standards/regulationsIEC 60947-1
EN 60947-4-2
IEC 61508
ISO 13849
Safety Integrity Level according to IEC 61508SIL 3 (safe shutdown)
SIL 2 (motor protection)
Category acc. to EN ISO 138493 (Safe shutdown)
Performance level according to ISO 13849e (Safe shutdown)

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.