View larger
ELR H5-IES-SC- 24DC/500AC-0,6 2900582 PHOENIX CONTACT Hybrid motor starter for reversing 3~ AC motors up to ..
ELR H5-IES-SC-24DC/500AC-0,6
2900582
PHOENIX CONTACT
1 Pcs.
Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A Phoenix Contact hybrid motor starter (ELR H5-IES-SC-24DC/500AC-0,6) combines semiconductor and relay technologies to provide safe reversing control and overload monitoring for low-current AC motors. Space-saving hybrid starters are ideal for high-density control cabinet installations requiring frequent switching cycles.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter: Reversing starter
- With short-circuit release: No
- Rated control supply voltage DC: 19.2 V
- Voltage type for actuating: DC
- Rated operation current Ie: 0.6 A
- Rated operation current at AC-3, 400 V: 0.6 A
- Overload release current setting: 0.075 A
- Temperature compensated overload protection: No
- Release class: CLASS 10
- Type of electrical connection of main circuit: Screw connection
- Suitable for rail mounting: Yes
- Number of command positions: 1
- Suitable for emergency stop: Yes
- External reset possible: Yes
- Degree of protection (IP): IP20
- Width: 22.5 mm
More info
▲Input data
| Input name | Device supply |
|---|---|
| Rated control circuit supply voltage US | 24 V DC |
| Rated control supply current IS | 40 mA |
| Protective circuit | Protection against polarity reversal Parallel polarity protection diode |
| Surge protection | |
| Operating voltage display | Green LED |
| Status display | Yellow LED |
| Indication | Red LED |
| Input name | Control input right/left |
| Rated actuating voltage UC | 24 V DC |
| Rated actuating current IC | 5 mA |
| Switching threshold | 9.6 V (“0” signal) |
| 19.2 V (“1” signal) | |
| Switching level | < 5 V DC (For EMERGENCY STOP) |
| Protective circuit | Protection against polarity reversal |
| Typical turn-off time | < 30 ms |
Output data load output
| Rated operating voltage Ue | 500 V AC |
|---|---|
| Operating voltage range | 42 V AC ... 550 V AC |
| Load current range | 75 mA ... 600 mA (see to derating) |
| Trigger characteristic in acc. with IEC 60947 | Class 10A |
| Rated operating current at AC-51 | 0.6 A |
| Rated operating current at AC-53a | 0.6 A |
| Leakage current | 0 mA |
| Protective circuit | Surge protection Varistor |
Output data reply output
| Note | Confirmation: floating change-over contact, signal contact |
|---|---|
| Contact type | 1 PDT |
Connection data, control circuit
| Connection name | Control circuits |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
General
| Switching frequency | ≤ 2 Hz (Load-dependent) |
|---|---|
| Mounting position | vertical (horizontal DIN rail, motor output below) |
| Assembly instructions | alignable, for spacing see derating |
| Operating mode | 100% operating factor |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60947-1 |
| EN 60947-4-2 | |
| IEC 61508 | |
| ISO 13849 | |
| Safety Integrity Level according to IEC 61508 | SIL 3 (safe shutdown) |
| SIL 2 (motor protection) | |
| Category acc. to EN ISO 13849 | 3 (Safe shutdown) |
| Performance level according to ISO 13849 | e (Safe shutdown) |
Dimensions
| Width | 22.5 mm |
|---|---|
| Height | 99 mm |
| Depth | 114.5 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Degree of protection | IP20 |