View larger
ELR H5-IES-SC-230AC/500AC-2 2900420 PHOENIX CONTACT Hybrid motor starter for reversing 3~ AC motors up to 50..
ELR H5-IES-SC-230AC/500AC-2
2900420
PHOENIX CONTACT
1 Pcs.
Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Phoenix Contact hybrid motor starter, part number ELR H5-IES-SC-230AC/500AC-2, combines electronic switching technology with electromechanical reliability for reversing three-phase AC motors. Hybrid motor starters provide extended service life and compact switching capabilities in modern industrial automation layouts. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter: Reversing starter
- With short-circuit release: No
- Rated control supply voltage AC 50 Hz: 85 V
- Rated control supply voltage AC 60 Hz: 85 V
- Voltage type for actuating: AC
- Rated operation current Ie: 2.4 A
- Rated operation current at AC-3, 400 V: 2.4 A
- Overload release current setting: 0.18 A
- Temperature compensated overload protection: No
- Release class: CLASS 10
- Type of electrical connection of main circuit: Screw connection
- Suitable for rail mounting: Yes
- Number of command positions: 1
- Suitable for emergency stop: Yes
- External reset possible: Yes
- Degree of protection (IP): IP20
More info
▲Input data
| Input name | Device supply |
|---|---|
| Rated control circuit supply voltage US | 230 V AC (50/60 Hz) |
| Rated control supply current IS | 4 mA |
| Protective circuit | Surge protection |
| Operating voltage display | Green LED |
| Status display | Yellow LED |
| Indication | Red LED |
| Input name | Control input right/left |
| Rated actuating voltage UC | 230 V AC |
| Rated actuating current IC | 7 mA |
| Switching threshold | 44 V AC (“0” signal) |
| 85 V AC (“1” signal) | |
| Switching level | < 5 V AC (For EMERGENCY STOP) |
| Typical turn-off time | < 70 ms |
Output data load output
| Rated operating voltage Ue | 500 V AC |
|---|---|
| Operating voltage range | 42 V AC ... 550 V AC |
| Load current range | 180 mA ... 2.4 A (see to derating) |
| Trigger characteristic in acc. with IEC 60947 | Class 10A |
| Rated operating current at AC-51 | 2.4 A |
| Rated operating current at AC-53a | 2.4 A |
| Leakage current | 0 mA |
| Protective circuit | Surge protection |
Output data reply output
| Note | Confirmation: floating change-over contact, signal contact |
|---|---|
| Contact type | 1 PDT |
Connection data, control circuit
| Connection name | Control circuits |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
General
| Switching frequency | ≤ 2 Hz (Load-dependent) |
|---|---|
| Mounting position | vertical (horizontal DIN rail, motor output below) |
| Assembly instructions | alignable, for spacing see derating |
| Operating mode | 100% operating factor |
| Designation | Standards/regulations |
| Standards/regulations | IEC 60947-1 |
| EN 60947-4-2 | |
| IEC 61508 | |
| ISO 13849 | |
| Safety Integrity Level according to IEC 61508 | SIL 3 (safe shutdown) |
| SIL 2 (motor protection) | |
| Category acc. to EN ISO 13849 | 3 (Safe shutdown) |
| Performance level according to ISO 13849 | e (Safe shutdown) |
Dimensions
| Width | 22.5 mm |
|---|---|
| Height | 99 mm |
| Depth | 114.5 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Degree of protection | IP20 |