View larger
ELR H5-I-SC- 24DC/500AC-2 2900574 PHOENIX CONTACT Hybrid motor starter
ELR H5-I-SC-24DC/500AC-2
2900574
PHOENIX CONTACT
1 Pcs.
Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact hybrid motor starter ELR H5-I-SC-24DC/500AC-2 combines electronic switching technology with electromechanical relays for reliable motor control in compact footprints. Hybrid starters offer extended operational lifespans by minimizing mechanical wear during frequent switching cycles. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Reversing starter
- With short-circuit release (EF006691): No
- Rated control supply voltage DC (EF003980): 19.2 V
- Voltage type for actuating (EF008242): DC
- Rated operation current Ie (EF001443): 2.4 A
- Rated operation current at AC-3, 400 V (EF009602): 2.4 A
- Overload release current setting (EF002336): 0.18 A
- Temperature compensated overload protection (EF009604): No
- Release class (EF006668): CLASS 10
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for rail mounting (EF003972): Yes
- Number of command positions (EF001372): 1
- External reset possible (EF003426): Yes
- Degree of protection (IP) (EF005474): IP20
- Width (EF000008): 22.5 mm
- Height (EF000040): 107 mm
More info
▲Key Commercial Data
| Orderkey | 2900574 |
|---|---|
| Packing unit | 1 pc |
| Catalog page | Page 25 (C-5-2017) |
| GTIN | 4046356527866 |
| Weight per Piece (excluding packing) | 218.110 g |
| Custom tariff number | 85371098 |
| Country of origin | DE (Germany) |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Degree of protection | IP20 |
Device supply
| Rated control circuit supply voltage US | 24 V DC |
|---|---|
| Control supply voltage range | 19.2 V DC ... 30 V DC |
| Rated control supply current IS | 40 mA |
| Type of protection | Surge protection |
| Reverse polarity protection |
Input data
| Input name | Control input right/left |
|---|---|
| Rated actuating voltage UC | 24 V DC |
| Triggering voltage range | 19.2 V DC ... 30 V DC |
| Rated actuating current IC | 5 mA (Input type 1) |
| Switching threshold | 9.6 V (“0” signal) |
| 19.2 V (“1” signal) | |
| Typical turn-off time | < 30 ms |
| Type of protection | Reverse polarity protection |
Output data load output
| Output name | AC output |
|---|---|
| Rated operating voltage Ue | 500 V AC |
| Operating voltage range | 42 V AC ... 550 V AC |
| Rated operating current Ie | 2.4 A (AC-51) |
| 2.4 A (AC-53a) | |
| Mains frequency | 50/60 Hz |
| Load current range | 180 mA ... 2.4 A (see to derating) |
| Trigger characteristic in acc. with IEC 60947-4-2 | Class 10A |
| Cooling time | 20 min. (for auto reset) |
| Leakage current | 0 mA |
| Type of protection | Surge protection |
Output data reply output
| Output name | Acknowledge output |
|---|---|
| Note | Confirmation: floating change-over contact, signal contact |
| Contact type | 1 PDT |
| Switching capacity according to IEC 60947-5-1 | 3 A (230 V, AC15) |
| 2 A (24 V, DC13) |
General
| Switching frequency | ≤ 2 Hz (Load-dependent) |
|---|---|
| Mounting position | vertical (horizontal DIN rail, motor output below) |
| Mounting type | DIN rail mounting |
| Assembly instructions | alignable, for spacing see derating |
| Operating mode | 100% operating factor |
| Maximum power dissipation | 3.3 W |
| Minimum power dissipation | 1.1 W |
| Operating voltage display | Green LED |
| Status display | Yellow LED |
| Indication | Red LED |
Connection data 1
| Connection name | Control circuits |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
Connection data 2
| Connection name | Load circuit |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
UL data
| SCCR | 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
|---|---|
| 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) | |
| FLA | 2.4 A (500 V AC) |
| Group installation | 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
| 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) | |
| Category code | NLDX / NRNT |
Insulation characteristics
| Rated insulation voltage | 500 V |
|---|---|
| Rated surge voltage | 6 kV |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Designation | Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
| Insulation | Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC (e.g., 230/400 V AC, 277/480 V AC) |
| Safe isolation (EN 50178) at operating voltage ≤ 300 V A (e.g., 230/400 V AC, 277/480 V AC) | |
| Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC | |
| Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC | |
| Designation | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
| Insulation | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
| Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
Standards and Regulations
| Designation | Standards/regulations |
|---|---|
| Standards/regulations | IEC 60947-1 |
| IEC 60947-4-2 | |
| IEC 61508 | |
| ISO 13849 |
Environmental Product Compliance
| China RoHS | Environmentally Friendly Use Period = 50 |
|---|---|
| For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |