View larger
ELR H3-IES-SC-230AC/500AC-2 2900568 PHOENIX CONTACT 3 in 1 hybrid motor starter for starting 3~ AC motors up..
ELR H3-IES-SC-230AC/500AC-2
2900568
PHOENIX CONTACT
1 Pcs.
Automation > Motor starter/Motor starter combination
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Phoenix Contact ELR H3-IES-SC-230AC/500AC-2 is a hybrid motor starter engineered for efficient, solid-state switching and protection of industrial three-phase AC motors. Such devices integrate seamlessly into control panels to frequently cycle machinery while minimizing mechanical wear. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Type of motor starter (EF009598): Direct starter
- With short-circuit release (EF006691): No
- Rated control supply voltage AC 50 Hz (EF003978): 85 V
- Rated control supply voltage AC 60 Hz (EF003979): 85 V
- Voltage type for actuating (EF008242): AC
- Rated operation current Ie (EF001443): 2.4 A
- Rated operation current at AC-3, 400 V (EF009602): 2.4 A
- Overload release current setting (EF002336): 0.18 A
- Temperature compensated overload protection (EF009604): No
- Release class (EF006668): CLASS 10
- Type of electrical connection of main circuit (EF006819): Screw connection
- Suitable for rail mounting (EF003972): Yes
- Number of command positions (EF001372): 1
- Suitable for emergency stop (EF001433): Yes
- External reset possible (EF003426): Yes
- Degree of protection (IP) (EF005474): IP20
More info
▲Dimensions
| Width | 22.5 mm |
|---|---|
| Height | 99 mm |
| Depth | 114.5 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 70 °C (observe derating) |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Degree of protection | IP20 |
Device supply
| Rated control circuit supply voltage US | 230 V AC (50/60 Hz) |
|---|---|
| Control supply voltage range | 85 V AC ... 253 V AC |
| Rated control supply current IS | 4 mA |
| Protective circuit | Surge protection |
Input data
| Input name | Control input right/left |
|---|---|
| Rated actuating voltage UC | 230 V AC |
| Voltage range | 85 V AC ... 253 V AC |
| Rated actuating current IC | 7 mA |
| Switching threshold | 44 V AC (“0” signal) |
| 85 V AC (“1” signal) | |
| Switching level | < 5 V AC (For EMERGENCY STOP) |
| Typical turn-off time | < 70 ms |
Output data load output
| Output name | AC output |
|---|---|
| Rated operating voltage Ue | 500 V AC |
| Operating voltage range | 42 V AC ... 550 V AC |
| Mains frequency | 50 Hz |
| 60 Hz | |
| Load current range | 180 mA ... 2.4 A (see to derating) |
| Trigger characteristic in acc. with IEC 60947 | Class 10A |
| Cooling time | 20 min. (for auto reset) |
| Rated operating current at AC-51 | 2.4 A |
| Rated operating current at AC-53a | 2.4 A |
| Leakage current | 0 mA |
| Protective circuit | Surge protection |
Output data reply output
| Output name | Acknowledge output |
|---|---|
| Note | Confirmation: floating change-over contact, signal contact |
| Contact type | 1 PDT |
| Switching capacity according to IEC 60947-5-1 | 3 A (230 V, AC15) |
| 2 A (24 V, DC13) |
General
| Switching frequency | ≤ 2 Hz (Load-dependent) |
|---|---|
| Mounting position | vertical (horizontal DIN rail, motor output below) |
| Assembly instructions | alignable, for spacing see derating |
| Operating mode | 100% operating factor |
| Maximum power dissipation | 4.1 W |
| Minimum power dissipation | 0.88 W |
| Operating voltage display | Green LED |
| Status display | Yellow LED |
| Indication | Red LED |
Connection data, input side
| Connection name | Control circuits |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
Connection data, output side
| Connection name | Load circuit |
|---|---|
| Connection method | Screw connection |
| Stripping length | 8 mm |
| Screw thread | M3 |
| Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 |
| Torque | 0.5 Nm ... 0.6 Nm |
Standards/regulations
| Designation | Standards/regulations |
|---|---|
| Standards/regulations | IEC 60947-1 |
| EN 60947-4-2 | |
| IEC 61508 | |
| ISO 13849 |
Insulation characteristics
| Rated insulation voltage | 500 V |
|---|---|
| Rated surge voltage | 4 kV |
| Overvoltage category | III |
| Degree of pollution | 2 |
| Designation | Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit |
| Insulation | Safe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC |
| Safe isolation (EN 50178) at operating voltage ≤ 300 V AC | |
| Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC | |
| Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC | |
| Designation | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
| Insulation | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
| Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
Approvals/conformities
| Safety Integrity Level according to IEC 61508 | SIL 3 (safe shutdown) |
|---|---|
| SIL 2 (motor protection) | |
| Category acc. to EN ISO 13849 | 3 (Safe shutdown) |
| Performance level according to ISO 13849 | e (Safe shutdown) |
| ATEX | II (2) G [Ex e] [Ex d] [Ex px] |
| II (2) D [Ex t] [Ex p] | |
| EU-type examination certificate | PTB 07 ATEX 3145 |
UL data
| SCCR | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
|---|---|
| 5 kA (480 V AC (fuse: 20 A RK5 (standard fault))) | |
| FLA | 2.4 A (480 V AC) |
| Group installation | 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
| 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) | |
| Category code | NLDX / NRNT |
Standards and Regulations
| Designation | Standards/regulations |
|---|---|
| Standards/regulations | IEC 60947-1 |
| EN 60947-4-2 | |
| IEC 61508 | |
| ISO 13849 | |
| ATEX | II (2) G [Ex e] [Ex d] [Ex px] |
| II (2) D [Ex t] [Ex p] |
eCl@ss
| eCl@ss 4.0 | 27371102 |
|---|---|
| eCl@ss 4.1 | 27371102 |
| eCl@ss 5.0 | 27371601 |
| eCl@ss 5.1 | 27371601 |
| eCl@ss 6.0 | 27371601 |
| eCl@ss 7.0 | 27371601 |
| eCl@ss 8.0 | 27370905 |
| eCl@ss 9.0 | 27370905 |
ETIM
| ETIM 2.0 | EC000066 |
|---|---|
| ETIM 3.0 | EC000066 |
| ETIM 4.0 | EC000066 |
| ETIM 5.0 | EC002055 |
UNSPSC
| UNSPSC 6.01 | 30211915 |
|---|---|
| UNSPSC 7.0901 | 39121514 |
| UNSPSC 11 | 39121514 |
| UNSPSC 12.01 | 39121514 |
| UNSPSC 13.2 | 39121514 |