View larger
MINI MCR-SL-UI-I-LP-NC 2902829 PHOENIX CONTACT 2-way loop-powered isolating amplifier (supplied on the outpu..
MINI MCR-SL-UI-I-LP-NC
2902829
PHOENIX CONTACT
1 Pcs.
Automation > Isolation amplifier
INTERFACE Components (IF)
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Configured for efficient signal conditioning, the MINI MCR-SL-UI-I-LP-NC 2902829 PHOENIX CONTACT 2-way loop-powered isolating amplifier (supplied on the outpu.. provides galvanic isolation and conversion for industrial process measurements. Loop-powered isolating amplifiers draw their operating energy directly from the output signal loop, simplifying control panel wiring.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of input ranges -60 mV ... +60 mV (EF006927): 1
- Number of input ranges -100 mV ... +100 mV (EF006912): 1
- Number of input ranges -300 mV ... +300 mV (EF006920): 1
- Number of input ranges -500 mV ... +500 mV (EF006926): 1
- Number of input ranges -1 V ... +1 V (EF006906): 0
- Number of input ranges -2 V ... +2 V (EF006913): 1
- Number of input ranges -2.5 V ... +2.5 V (EF006915): 1
- Number of input ranges -5 V ... +5 V (EF006923): 1
- Number of input ranges -10 V ... +10 V (EF006909): 1
- Number of input ranges -20 V ... +20 V (EF006917): 1
- Number of input ranges 0 mV ... 60 mV (EF006905): 1
- Number of input ranges 0 mV ... 100 mV (EF006893): 1
- Number of input ranges 0 mV ... 200 mV (EF006898): 1
- Number of input ranges 0 mV ... 300 mV (EF006901): 1
- Number of input ranges 0 mV ... 500 mV (EF006904): 1
- Number of input ranges 0 V ... 1 V (EF006890): 0
More info
▲Product description
The 6.2 mm wide MINI MCR-SL-UI-I-LP... configurable 2-way isolating amplifier is used to electrically isolate, condition, and filter analog signals.
The output loops that supply the loop-powered isolating amplifier enable the isolating amplifier to operate on an active analog input module. The modules are supplied via the current loop of the controller.
On the input side, standard analog signals and non-standard analog signals can be connected, starting from 2 mA or 50 mV up to 40 mA or 30 V. These are converted to a 4...20 mA signal.
The DIP switches accessible on the housing side enable the configuration of input signal ranges.
Dimensions
| Width | 6.2 mm |
|---|---|
| Height | 93.1 mm |
| Depth | 102.5 mm |
Ambient conditions
| Ambient temperature (operation) | -25 °C ... 70 °C |
|---|---|
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Degree of protection | IP20 |
Input data
| Number of inputs | 1 |
|---|---|
| Voltage input signal | 0 mV ... 1000 mV |
| 0 mV ... 750 mV | |
| 0 mV ... 500 mV | |
| 0 mV ... 300 mV | |
| 0 mV ... 250 mV | |
| 0 mV ... 200 mV | |
| 0 mV ... 150 mV | |
| 0 mV ... 125 mV | |
| 0 mV ... 120 mV | |
| 0 mV ... 100 mV | |
| 0 mV ... 75 mV | |
| 0 mV ... 60 mV | |
| 0 mV ... 50 mV | |
| 0 V ... 10 V | |
| 0 V ... 7.5 V | |
| 0 V ... 5 V | |
| 0 V ... 3 V | |
| 0 V ... 2.5 V | |
| 0 V ... 2 V | |
| 0 V ... 1.5 V | |
| 0 V ... 1.25 V | |
| 0 V ... 1.2 V | |
| 0 V ... 30 V | |
| 0 V ... 25 V | |
| 0 V ... 20 V | |
| 0 V ... 12.5 V | |
| 0 V ... 12 V | |
| 0 V ... 15 V | |
| -1000 mV ... 1000 mV | |
| -750 mV ... 750 mV | |
| -500 mV ... 500 mV | |
| -300 mV ... 300 mV | |
| -250 mV ... 250 mV | |
| -200 mV ... 200 mV | |
| -125 mV ... 125 mV | |
| -120 mV ... 120 mV | |
| -150 mV ... 150 mV | |
| -100 mV ... 100 mV | |
| -75 mV ... 75 mV | |
| -60 mV ... 60 mV | |
| -50 mV ... 50 mV | |
| -10 V ... 10 V | |
| -7.5 V ... 7.5 V | |
| -5 V ... 5 V | |
| -3 V ... 3 V | |
| -2.5 V ... 2.5 V | |
| -2 V ... 2 V | |
| -1.25 V ... 1.25 V | |
| -1.2 V ... 1.2 V | |
| -1.5 V ... 1.5 V | |
| -30 V ... 30 V | |
| -25 V ... 25 V | |
| -20 V ... 20 V | |
| -12.5 V ... 12.5 V | |
| -12 V ... 12 V | |
| -15 V ... 15 V | |
| 200 mV ... 1000 mV | |
| 150 mV ... 750 mV | |
| 100 mV ... 500 mV | |
| 60 mV ... 300 mV | |
| 50 mV ... 250 mV | |
| 40 mV ... 200 mV | |
| 25 mV ... 125 mV | |
| 24 mV ... 120 mV | |
| 30 mV ... 150 mV | |
| 20 mV ... 100 mV | |
| 15 mV ... 75 mV | |
| 12 mV ... 60 mV | |
| 10 mV ... 50 mV | |
| 2 V ... 10 V (additional areas can be configured, see table) | |
| 1.5 V ... 7.5 V | |
| 1 V ... 5 V | |
| 0.6 V ... 3 V | |
| 0.5 V ... 2.5 V | |
| 0.4 V ... 2 V | |
| 0.25 V ... 1.25 V | |
| 0.24 V ... 1.2 V | |
| 0.3 V ... 1.5 V | |
| 6 V ... 30 V | |
| 5 V ... 25 V | |
| 4 V ... 20 V | |
| 2.5 V ... 12.5 V | |
| 2.4 V ... 12 V | |
| 3 V ... 15 V | |
| Current input signal | 0 mA ... 40 mA |
| 0 mA ... 30 mA | |
| 0 mA ... 20 mA | |
| 0 mA ... 12 mA | |
| 0 mA ... 10 mA | |
| 0 mA ... 8 mA | |
| 0 mA ... 7.5 mA | |
| 0 mA ... 5 mA | |
| 0 mA ... 6 mA | |
| 0 mA ... 4 mA | |
| 0 mA ... 3 mA | |
| 0 mA ... 2.5 mA | |
| 0 mA ... 2 mA | |
| -40 mA ... 40 mA | |
| -30 mA ... 30 mA | |
| -20 mA ... 20 mA | |
| -12 mA ... 12 mA | |
| -10 mA ... 10 mA | |
| -8 mA ... 8 mA | |
| -7.5 mA ... 7.5 mA | |
| -5 mA ... 5 mA | |
| -6 mA ... 6 mA | |
| -4 mA ... 4 mA | |
| -3 mA ... 3 mA | |
| -2.5 mA ... 2.5 mA | |
| -2 mA ... 2 mA | |
| 8 mA ... 40 mA | |
| 6 mA ... 30 mA | |
| 4 mA ... 20 mA | |
| 2.4 mA ... 12 mA | |
| 2 mA ... 10 mA | |
| 1.6 mA ... 8 mA | |
| 1.5 mA ... 7.5 mA | |
| 1 mA ... 5 mA | |
| 1.2 mA ... 6 mA | |
| 0.8 mA ... 4 mA | |
| 0.6 mA ... 3 mA | |
| 0.5 mA ... 2.5 mA | |
| 0.4 mA ... 2 mA | |
| Max. input voltage | < 40 V |
| Max. input current | < 50 mA (Dielectric strength up to 30 V) |
| Input resistance of voltage input | approx. 100 kΩ (At ≤ 1 V, otherwise approximately 1 MΩ) |
| Input resistance current input | ≤ 50 Ω |
Output data
| Number of outputs | 1 |
|---|---|
| Configurable/programmable | Yes, preconfigured |
| Current output signal | 4 mA ... 20 mA |
| Max. output current | 35 mA (output limit) |
| Load/output load current output | (UB- 8 V) / 22 mA |
Power supply
| Supply voltage range | no separate supply voltage necessary |
|---|---|
| Power consumption | 28 mW (without signal) |
Connection data
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 2.5 mm² |
| Conductor cross section AWG min. | 26 |
| Conductor cross section AWG max. | 12 |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 2.5 mm² |
| Stripping length | 12 mm |
| Screw thread | M3 |
General
| No. of channels | 1 |
|---|---|
| Maximum transmission error | < 0.1 % (of final value) |
| < 0.2 % (Without adjustment) | |
| Maximum temperature coefficient | 0.01 %/K |
| Temperature coefficient, typical | 0.005 %/K |
| Limit frequency (3 dB) | approx. 30 Hz |
| Alignment zero | ± 2 % |
| Alignment span | ± 2 % |
| Step response (10-90%) | approx. 16 ms |
| Electrical isolation | Basic insulation according to EN 61010 |
| Overvoltage category | II |
| Pollution degree | 2 |
| Rated insulation voltage | 50 V AC/DC |
| Test voltage input/output | 1.5 kV (50 Hz, 1 min.) |
| Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
| Color | green |
| Housing material | PBT |
| Mounting position | any |
| Conformance | CE-compliant |
| ATEX | Ex II 3 G Ex nA IIC T4 Gc X |
| UL, USA / Canada | UL 508 Listed |
| Class I, Div. 2, Groups A, B, C, D T5 | |
| Class I, Zone 2, Group IIC | |
| Certificate of classification | DNV GL 14085-15HH |
EMC data
| Designation | Electromagnetic RF field |
|---|---|
| Standards/regulations | EN 61000-4-3 |
| Typical deviation from the measuring range final value | 0.5 % |
| Designation | Fast transients (burst) |
| Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 2 % |
| Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 |
| Typical deviation from the measuring range final value | 0.5 % |