An ECOR-1-BSC2/FO/2X21 1308332 PHOENIX CONTACT ECOR-1 relay socket, for FASTON relay, Fork terminal, 2 switched.. is a dedicated base housing designed to interface specialized industrial relays with control circuit wiring via fork terminals. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- General: Screw connections that are not required should be tightened with the torque.
- Product Type: Relay socket
- Product Family: ESSENTIAL edition
- Surge Category: Ii
- Degree of pollution: 2
- Test Voltage (Winding/Contact): 4 kV Eff (50 Hz, 1 min., winding/contact)
- Test Voltage (): 1 kV Eff (50 Hz, 1 min., open contact)
- Dimensioning Transient Voltage: 2.5 kV
- Nominal Input Voltage U N: ≤ 230 V AC
- Connection type: Fork Terminal
- Rigid conductor section: 0.4 mm² ... 1.5 mm²
- Flexible conductor section: 0.4 mm² ... 1.5 mm²
- AWG Conductor Section: 21 ... 16
- Tightening torque: 1 Nm
- Width: 15.7 mm
- Height: 71 mm
More info
▲| General | They should not be used to separate SELV/PELV electrical circuits from other electrical circuits, as safe separation is not guaranteed. |
| General | Protection against accidental contact of the article (with voltages > 25 V AC/60 V DC) must be ensured by the system manufacturer. This is an assembly device without protection against direct contact. |
| General | A basic isolation from adjacent modules in the direction of the DIN rail is satisfied. If the application requires higher requirements in terms of insulation (reinforced insulation), it should be carried out with appropriate measures (e.g. partition plates). |
| General | Screw connections that are not required should be tightened with the torque. |
| Product Type | Relay socket |
| Product Family | ESSENTIAL edition |
| Insulation Properties: Leak Lines and Air Gaps Between Circuits | |
| Isolation | Basic Insulation |
| Surge Category | Ii |
| Degree of pollution | 2 |
| Test Voltage (Winding/Contact) | 4 kVEff(50 Hz, 1 min., winding/contact) |
| Test Voltage () | 1 kVEff(50 Hz, 1 min., open contact) |
| Creepage lines and air gaps between circuits | |
| Sizing Insulation Voltage | 250 V AC |
| Dimensioning Transient Voltage | 2.5 kV |
| Nominal Input Voltage UN | ≤ 230 V AC |
| Connection type | Fork Terminal |
| Rigid conductor section | 0.4 mm² ... 1.5 mm² |
| Flexible conductor section | 0.4 mm² ... 1.5 mm² |
| AWG Conductor Section | 21 ... 16 |
| Tightening torque | 1 Nm |
| Width | 15.7 mm |
| Height | 71 mm |
| Depth | 35.6 mm |
| Environmental conditions | |
| Protection Index | IP20 |
| Ambient Temperature (Service) | -40 °C ... 70 °C |
| Ambient Temperature (Storage/Transport) | -40 °C ... 70 °C |
| Ce | |
| Certificate | CE Compliance |
| UKCA | |
| Certificate | UKCA Compliant |
| Standards/Specifications | IEC 60664-1 |
| Creepage lines and air gaps between circuits | |
| Standards/Specifications | IEC 60664-1 |
| Type of mounting | Rail mounting |
| Installation instructions | Alignable without separation |
| Position for mounting | discretionary |