PHOENIX CONTACT REL-FO/LD-24DC/1X21MS REL-FO/LD-24DC/1X21MS 1308302 PHOENIX CONTACT Plug-in miniature relay with mechanical switching position ind.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

REL-FO/LD-24DC/1X21MS 1308302 PHOENIX CONTACT Plug-in miniature relay with mechanical switching position ind..

REL-FO/LD-24DC/1X21MS

1308302

PHOENIX CONTACT

10 Pcs.

Plug-in miniature relay with mechanical switching position indicator, FASTON connection, 1 switch, status indication: LED (yellow), Free circulation diode, Input voltage: 24 V DC REL-FO/LD-24DC/1X21MS - Single Relay Plug-in miniature relay with mechanical switching position indicator, FASTON connection, 1 changeover contact, status display: Yellow LED, Freewheeling diode, Input voltage: 24 V DC

Automation > Switching relay
Industrial Relays

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A Phoenix Contact miniature relay (REL-FO/LD-24DC/1X21MS) is engineered for high-reliability switching tasks within industrial machinery, offering robust electromechanical performance and clear mechanical position indicators.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product type: Single relay
  • Product family: ESSENTIAL edition
  • Operating mode: 100% operating factor
  • Mechanical service life: approx. 5x 10 7 cycles
  • Relay type: Electromechanical relay
  • Overvoltage category: II
  • Pollution degree: 3
  • Maximum power dissipation for nominal condition: 0.64 W
  • Test voltage (Winding/contact): 5 kV rms (50 Hz, 1 min., winding/contact)
  • Test voltage (): 1 kV rms (50 Hz, 1 min., open contact)
  • Rated surge voltage: 2.5 kV
  • Coil side Nominal input voltage U N: 24 V DC
  • Input voltage range: 16.8 V DC ... 26.4 V DC
  • Drive and function: monostable
  • Drive (polarity): polarized
  • Typical input current at U N: 24 mA

More info

▲
Technical data

Notes
GeneralDo not use to separate SELV/PELV circuits from other circuits, because safe isolation is not guaranteed. (applies to the optocoupler variants)
GeneralThe system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.

Product properties
Product typeSingle relay
Product familyESSENTIAL edition
Operating mode100% operating factor
Mechanical service lifeapprox. 5x 107cycles
Relay typeElectromechanical relay
Insulation characteristics: Air clearances and creepage distances between the power circuits
InsulationBasic insulation
Overvoltage categoryII
Pollution degree3

Electrical properties
Maximum power dissipation for nominal condition0.64 W
Test voltage (Winding/contact)5 kVrms(50 Hz, 1 min., winding/contact)
Test voltage ()1 kVrms(50 Hz, 1 min., open contact)
Air clearances and creepage distances between the power circuits
Rated insulation voltage250 V AC
Rated surge voltage2.5 kV

Input data
Coil side
Nominal input voltage UN24 V DC
Input voltage range16.8 V DC ... 26.4 V DC
Drive and functionmonostable
Drive (polarity)polarized
Typical input current at UN24 mA
Input power dissipation for UN0.58 W
Typical response time9 ms
Typical release time10 ms
Protective circuitFreewheeling diode
Status displayYellow LED
Coil resistance1080 Ω ±10 %

Output data
Switching
Contact switching type1 changeover contact
Type of switch contactSingle contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (100 mA)
Limiting continuous current12 A
Maximum inrush current24 A (20 ms, N/O contacts)
Inrush current, minimum100 mA (5 V)
Interrupting rating (ohmic load) max.288 W (24 V DC)
360 W (30 V DC)
3000 VA (250 V AC)

Connection data
Cross section AWG(converted acc. to IEC)
Connection methodFASTON connection

Dimensions
Width13 mm
Height31.1 mm
Depth35 mm

Environmental and real-life conditions
Ambient conditions
Degree of protection (Relay)RT II (Relay)
Degree of protection (Installation location)IP54 (Installation location)
Ambient temperature (operation)-40 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 70 °C
Altitude≤ 2000 m

Standards and regulations
Standards/regulationsIEC 61810-1
IEC 60664-1
Air clearances and creepage distances between the power circuits
Standards/regulationsIEC 60664-1

Mounting
Mounting positionany

Product Datasheet