Product Overview

Connection flange for vacuum-resistant fibers, 1 channel from Panasonic, designated as UFVFR1, enables reliable feedthrough of optical sensing lines into vacuum chambers without compromising internal pressure integrity. Such components are essential in semiconductor manufacturing, vacuum coating, and high-vacuum research apparatus.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • Product Number: FV-FR1
  • Part Number: FV-FR1
  • Product: Vacuum-resistant flange 1CH
  • Details: Atmospheric side and vacuum side are isolated.
  • Product name: One-Touch Connection System Vacuum-resistant Fibers
  • Applicable fibers: FT-40V, FD-KZ50V, FD-L10V, FT-J9
  • Leakage: 1.0 x 10 -10 Pa·m 3 /s [He] or less (* Measured with a He detector)
  • Ambient humidity: 35 to 85% RH (Same for storage)
  • Tightening torque: Nut: 14.7 N·m or less (M14 nut)
  • Tensile strength: 20 N or less (Atmospheric / vacuum side fiber joint)
  • O-ring size: V15
  • Weight: 100 g approx.

More info

▲
Product NumberFV-FR1
Part NumberFV-FR1
ProductVacuum-resistant flange 1CH
DetailsAtmospheric side and vacuum side are isolated.
Product nameOne-Touch Connection System Vacuum-resistant Fibers

ItemSpecifications
Product NumberFV-FR1
Part NumberFV-FR1
Applicable fibersFT-40V, FD-KZ50V, FD-L10V, FT-J9
Leakage1.0 x 10-10 Pa·m3/s [He] or less (* Measured with a He detector)
Ambient temperature-30 to +120℃ -22 to +248℉
(Same for storage. Up to +40 ℃ +104℉ when humidity is high. However, no dew condensation or icing allowed.)
Ambient humidity35 to 85% RH (Same for storage)
Tightening torqueNut: 14.7 N·m or less (M14 nut)
Tensile strength20 N or less (Atmospheric / vacuum side fiber joint)
O-ring sizeV15
Weight100 g approx.
MaterialMain unit: Stainless steel (SUS303), Holding bracket: Stainless steel (SUS301),
Fiber: Quartz glass, O-ring: Fluororubber
Recommended thickness of vacuum chamber wall3.0 to 40.0 mm 0.118 to 1.575 in
(Note) : Confirm the wall thickness in advance since the FV-FR1 cannot be installed to a vacuum chamber with a wall thickness outside the recommended thickness range.