View larger
UEXF61 EXF61 EX-F61 PANASONIC Chemical resistant leak sensor, PFA mounting, NPN, 12-24VDC
UEXF61
UEXF61
PANASONIC
1 unit
Automation > Special Photoelectric Sensors - PANASONIC
Special Photoelectric Sensors - PANASONIC
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The UEXF61 EXF61 EX-F61 Panasonic Chemical resistant leak sensor, PFA mounting, NPN, 12-24VDC detects liquid presence to prevent equipment damage and hazardous spills in industrial fluid systems. Liquid leak sensors are routinely installed near piping connections, chemical baths, and semiconductor processing equipment to provide early warning signals to plant control systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Product Number: EX-F61
- Part Number: EX-F61
- Product: Leak Detection Sensor
- Details: Chemical-resistant
- Product name: Leak Detection Sensor EX-F70/EX-F60
- Supply voltage: 12 to 24 V DC ± 10 % Ripple P-P 10 % or less
- Current consumption: 15 mA or less
- Output:Output operation: In normal state: ON, When leak detected or the sensor is mounted improperly: OFF
- Output:Short-circuit protection: Incorporated
- Response time: 50 ms or less
- FAULT indicator: Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly)
- NORMAL indicator: Green LED (lights up when the sensor is mounted properly)
- Protection: IP67 (IEC)
- Ambient humidity: 35 to 85 % RH, Storage: 35 to 85 % RH
More info
▲| Product Number | EX-F61 |
| Part Number | EX-F61 |
| Product | Leak Detection Sensor |
| Details | Chemical-resistant |
| Product name | Leak Detection Sensor EX-F70/EX-F60 |
| Item | Specifications |
|---|---|
| Product Number | EX-F61 |
| Part Number | EX-F61 |
| Sensing object | Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. |
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
| Current consumption | 15 mA or less |
| Output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) |
| Output:Output operation | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF |
| Output:Short-circuit protection | Incorporated |
| Response time | 50 ms or less |
| FAULT indicator | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) |
| NORMAL indicator | Green LED (lights up when the sensor is mounted properly) |
| Protection | IP67 (IEC) |
| Ambient temperature | -10 to +60 ℃+14 to +140 ℉(No dew condensation or icing allowed), Storage: -20 to +70 ℃- 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Ambient illuminance | Incandescent light: 1,000 ℓx or less at the light-receiving face |
| Emitting element | Infrared LED (non-modulated) |
| Material | Enclosure: PFA |
| Cable | 0.1 mm23-core PFA cabtyre cable, 3 m9.843 ftlong |
| Cable extension | Extension up to total 50 m164.042 ft |