ZX-EDA11 2M ZX 1001G ZXEDA112M OMRON Amp. Inductive NPN 3 outputs digit.+1analógica
ZX-EDA11 2M
ZX 1001G
ZXEDA112M
OMRON
1 Pcs.
Automation > Accessories/spare parts for sensor technology
ZX
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ZX-EDA11 2M OMRON amp. inductive NPN 3 outputs digit.+1analógica operates as an advanced sensor amplifier unit that processes incoming signals from connected displacement or proximity measurement heads. Signal amplifiers evaluate raw sensor data to deliver precise digital and analog outputs for factory automation feedback loops. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Cylindrical: 3 dia. × 18 mm
- 5.4 dia. × 18 mm: 1 mm
- 8 dia. × 22 mm: 2 mm
- Screw-shaped: M10×22 mm
- M18×46.3 mm: 7 mm
- Flat: 30×14×4.8 mm
- Heat-resistant, cylindrical: M12×22 mm
- DC: NPN
- PNP: ZX-EDA41
- Calculating unit: ZX-CAL2
- Attached to each sensor head: ZX-XBE1
- For DIN track mounting: ZX-XBE2
- ZX-series communications interface unit: ZX-SF11
- ZX-series sensor setup and logging software (CD-ROM): ZX-SW11EV3
- 1 m: ZX-XC1A
- 4 m: ZX-XC4A
More info
▲- High resolution of 1 µm
- High-speed response time of 150µs
- Easy sensor head replacement
- Modular platform concept for different sensing technologies
- Easy linearity adjustment for any metal
Specifications & ordering info
Ordering information
Sensors
Sensor heads
Resolution1 | ||||
|---|---|---|---|---|
ZX-ED01T2 | ||||
ZX-ED02T2 | ||||
ZX-EM02T2 | ||||
ZX-EM07MT2 | ||||
ZX-EM02HT4 |
Amplifier units
Note: Compatible connection with the sensor head.
Accessories (order separately)
Calculating unit
Amplifier mounting brackets
SmartMonitor sensor setup tool for Personal Computer connection
ZX-SFW11EV35 | |
Cables with connectors on both ends (for extension)*
*Robot cable models are also available. The model numbers are ZX-XC_R.
Specifications
Sensor heads
Magnetic metals | ||||||||
Resolution6 | ||||||||
Linearity7 | ±1% F.S.8 | |||||||
Temperature characteristic9 | ||||||||
Operating10 | ||||||||
Storage5 | ||||||||
1,000 VAC, 50/60 Hz for 1 min between charged parts and case | ||||||||
10 to 55 Hz with 1.5-mm double amplitude for 2 h each in X, Y, and Z directions | ||||||||
IEC60529, IP6011 | ||||||||
Amplifier units
Possible average count settings12 | 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096 | |
Linear output13 | Current output: 4 to 20 mA/F.S., max. load resistance: 300 Ω Voltage output:±4 V (±5 V, 1 to 5 V14), output impedance: 100 Ω | |
NPN open-collector outputs, 30 VDC, 50 mA max. | PNP open-collector outputs, 30 VDC, 50 mA max. | |
Zero reset input, timing input, reset input, judgement output hold input | ON: Supply voltage short-circuited or supply voltage within 1.5 V | |
| ||
Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), | ||
0.5% F.S. of linear output value at ±20% of power supply voltage | ||
140 mA max. with power supply voltage of 24 VDC (with sensor connected) | ||
Operating and storage: 0 to 50°C (with no icing or condensation) | ||
10 to 150 Hz with 0.7-mm double amplitude for 80 min each in X, Y, and Z directions | ||
300 m/s2, 3 times each in 6 directions (up, down, left, right, forward, backward) | ||
Case: PBT (polybutylene terephthalate), cover: Polycarbonate | ||
2.Models with protective spiral tubes are also available. Add a suffix of “-S” to the above model numbers when ordering. (Example: ZX-ED01T-S)
6.Accuracy: The resolution is the deviation (±3σ) in the linear output when connected to the ZX-EDA amplifier unit. The above values indicate the deviations observed 30 minutes after the power is turned ON.
(The resolution is measured with Omron's standard reference object at ½ of the measurement range with the ZX-EDA set for the maximum average count of 4,096 per period.)
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may be adversely affected under strong electromagnetic fields.
7.Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The linearity and measurement values vary with the object being measured.
9.Temperature characteristic: The temperature characteristic is measured with Omron's standard reference object at ½ of the measurement range.
12.The response speed of the linear output is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).
The response speed of the judgement outputs is calculated as the measurement period x (average count setting + 1) (with fixed sensitivity).