View larger
Y92F-30 Y92F3008R Y92F30,1 OMRON Anchor for mounting in panel
Y92F-30
Y92F3008R
Y92F30.1
OMRON
50 Pcs.
Automation > Accessories/spare parts for switching relay
Accessories
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Anchor for mounting in panel Y92F-30 from Omron is a specialized mechanical mounting accessory utilized to securely fasten panel-mounted timers and controllers onto enclosure cutouts. Panel mounting brackets ensure instruments remain firmly positioned despite mechanical shock and vibration. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Relay DPDT: 11
- 24 to 48 VAC/12 to 48 VDC: H3CR-A 24-48AC/12-48DC
- Transistor: 24 to 48 VAC/12 to 48 VDC
- Relay DPDT: 8
- 24 to 48 VAC/12 to 48 VDC: H3CR-A8 24-48AC/12-48DC
- Transistor: 24 to 48 VAC/12 to 48 VDC
- Relay SPDT: 100 to 240 VAC/100 to 125 VDC
- 24 to 48 VAC/VDC: H3CR-A8E 24-48AC/DC
- Relay DPDT: 11
- 24 VAC/VDC: H3CR-F 24-48AC/12-48DC
- 8: 100 to 240 VAC
- 24 VAC/VDC: H3CR-F8 24-48AC/12-48DC
- 11: 100 to 240 VAC
- 24 VAC/VDC: H3CR-FN 24-48AC/12-48DC
- 8: 100 to 240 VAC
- 24 VAC/VDC: H3CR-F8N 24-48AC/12-48DC
More info
▲Ordering information
Output | Number of pins | Supply voltage | Time range | Operating mode | Order code |
|---|---|---|---|---|---|
Relay DPDT | 11 | 100 to 240 VAC/100 to 125 VDC | 0.05 s to 300 h | ON-delay, flicker OFF start, flicker ON start, signal ON/OFF-delay, signal OFF-delay, interval | H3CR-A 100-240AC/100-125DC |
24 to 48 VAC/12 to 48 VDC | H3CR-A 24-48AC/12-48DC | ||||
Transistor | 24 to 48 VAC/12 to 48 VDC | 0.05 s to 300 h | H3CR-AS 24-48AC/12-48DC | ||
Relay DPDT | 8 | 100 to 240 VAC/100 to 125 VDC | 0.05 s to 300 h | ON-delay, flicker ON start, | H3CR-A8 100-240AC/100-125DC |
24 to 48 VAC/12 to 48 VDC | H3CR-A8 24-48AC/12-48DC | ||||
Transistor | 24 to 48 VAC/12 to 48 VDC | 0.05 s to 300 h | H3CR-A8S 24-48AC/12-48DC | ||
Relay SPDT | 100 to 240 VAC/100 to 125 VDC | H3CR-A8E 100-240AC/100-125DC | |||
24 to 48 VAC/VDC | H3CR-A8E 24-48AC/DC | ||||
Relay DPDT | 11 | 100 to 240 VAC | 0.05 s to 30 h | Flicker OFF start | H3CR-F 100-240AC/100-125DC |
24 VAC/VDC | H3CR-F 24-48AC/12-48DC | ||||
8 | 100 to 240 VAC | H3CR-F8 100-240AC/100-125DC | |||
24 VAC/VDC | H3CR-F8 24-48AC/12-48DC | ||||
11 | 100 to 240 VAC | 0.05 s to 30 h | Flicker ON start | H3CR-FN 100-240AC/100-125DC | |
24 VAC/VDC | H3CR-FN 24-48AC/12-48DC | ||||
8 | 100 to 240 VAC | H3CR-F8N 100-240AC/100-125DC | |||
24 VAC/VDC | H3CR-F8N 24-48AC/12-48DC | ||||
Time-limit contact and instantaneous contact | 100 to 120 VAC | Star-delta | H3CR-G8EL 100-120AC | ||
200 to 240 VAC | H3CR-G8EL 200-240AC | ||||
DPDT | 8 | 100 to 120 VAC | 0.05 to 12 s | Power OFF-delay | H3CR-H8LS 100-120AC |
200 to 240 VAC | H3CR-H8LS 200-240AC | ||||
24 VAC/VDC | H3CR-H8LS 24AC/DC | ||||
100 to 120 VAC | 0.05 to 12 m | H3CR-H8LM 100-120AC | |||
200 to 240 VAC | H3CR-H8LM 200-240AC | ||||
24 VAC/VDC | H3CR-H8LM 24AC/DC |
Accessories
Name/specifications | Order code | |
|---|---|---|
Flush-mounting adapter | Y92F-30 | |
Protective cover | Y92A-48B | |
Front connecting socket | 8-pin, finger-safe type, DIN-rail | P2CF-08-E |
Front connecting socket | 11-pin, finger-safe type, DIN-rail | P2CF-11-E |
Back connecting socket | 8-pin | P3G-08 |
11-pin | P3GA-11 | |
Name/specifications | Order code | |
|---|---|---|
Time setting ring | Setting a specific time | Y92S-27 |
Limiting the setting range | Y92S-28 | |
Panel cover | Light grey (5Y7/1) | Y92P-48GL |
Black (N1.5) | Y92P-48GB | |
Specifications
Accuracy of operating time | ±0.2% FS max. (±0.2% ±10 ms max. in a range of 1.2 s) | |
Influence of voltage | ±0.2% FS max. (±0.2% ±10 ms max. in a range of 1.2 s) | |
Influence of temperature | ±1% FS max. (±1% ±10 ms max. in a range of 1.2 s) | |
Ambient temperature | Operating: −10 to 55°C (with no icing), | |
Life expectancy | Mechanical | 20,000,000 operations min. (under no load at 1,800 operations/h) |
Electrical | 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) | |
Size in mm (H×W×D) | 48×48×66.6 (H3CR-A, -F), 48×48×78 (H3CR-G, -H) | |
Setting error | ±5% FS ±50 ms | |
Degree of protection | IP40 (panel surface) | |
Weight | Approx. 90 g | |