OMRON TH2-63X60RD TH2-63X60RD AA051661D TH263X60RD OMRON Flat LED Back light (15 mm), active area 63 x 60 mm, red, 24 VDC, M12.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details

TH2-63X60RD AA051661D TH263X60RD OMRON Flat LED Back light (15 mm), active area 63 x 60 mm, red, 24 VDC, M12..

TH2-63X60RD

AA051661D

TH263X60RD

OMRON

1 Pcs.

Flat LED Back light (15 mm), active area 63 x 60 mm, red, 24 VDC, M12 connector

Automation > Accessories/spare parts for sensor technology
Special

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A flat LED back light (15 mm), active area 63 x 60 mm, red, 24 VDC, M12, designated by Omron part number TH2-63X60RD, provides uniform machine vision illumination for accurate part inspection and dimensional profiling. Industrial backlights create high-contrast silhouettes to assist automated camera systems in distinguishing edges and features on fast-moving production lines. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • 24 VAC/DC: Thermocouple or platinum resistance thermometer
  • Transistor: Open collector: K8DT-TH1TD
  • 100-240 VAC: Relay: SPDT contact output
  • Transistor: Open collector: K8DT-TH1TA
  • 24 VAC/DC: Thermocouple
  • Transistor: Open collector: K8DT-TH2TD
  • 100-240 VAC: Relay: SPDT contact output
  • Transistor: Open collector: K8DT-TH2TA
  • Power supply voltage: K8DT-TH__D: 24 VAC 50/60 Hz or 24 VDC K8DT-TH__A: 100 to 240 VAC 50/60 Hz
  • Allowable voltage range: 85% to 110% of power supply voltage
  • Power consumption: 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max.
  • Sensor inputs: Thermocouple: K, J, T, E
  • Platinum-resistance thermometer: Pt100, Pt1000
  • Setting method: Set of three rotary DIP switches
  • Indicators: Power (PWR): Green, Alarm (ALM): Red
  • Output form: Relay: SPDT contact output Transistor: Open collector
  • Output relay ratings: Resistive load

More info

▲
Features

Temperature monitoring relay

Ideal to prevent heater overheating. Self-latching output to contribute to safe equipment operation.

  • Set the temperature with ultra-simple rotary switches
  • Digitally set the temperature to between 0 and 999°C in 1°C increments (K8DT-TH1__), or between 0 and 1,800°C in 10°C increments (K8DT-TH2__)
  • Connect a thermocouple or platinum resistance thermometer
  • Width of 17.5 mm to reduce space required in panels
  • Push-in plus Technology that reduce wiring work
  • UL listed for easy shipping to North America
  • Double-insertion holes for crossover wiring (all terminals)
  • Models added with transistor outputs for superior contact reliability

Ordering information

Power supply voltage

Input types

Setting units (setting range)

Output types

Order code

24 VAC/DC

Thermocouple or platinum resistance thermometer

Setting unit: 1°C or 1°F
(0 to 999°C/°F)

Relay: SPDT contact output

K8DT-TH1CD

Transistor: Open collector

K8DT-TH1TD

100-240 VAC

Relay: SPDT contact output

K8DT-TH1CA

Transistor: Open collector

K8DT-TH1TA

24 VAC/DC

Thermocouple

Setting unit: 10°C/°F

Relay: SPDT contact output

K8DT-TH2CD

Transistor: Open collector

K8DT-TH2TD

100-240 VAC

Relay: SPDT contact output

K8DT-TH2CA

Transistor: Open collector

K8DT-TH2TA

Accessories

Front Cover (Order separately)

Appearance

Order code

Y92A-D1A

Specifications

Item

K8DT-TH1

K8DT-TH2

Power supply voltage

K8DT-TH__D: 24 VAC 50/60 Hz or 24 VDC

K8DT-TH__A: 100 to 240 VAC 50/60 Hz

Allowable voltage range

85% to 110% of power supply voltage

Power consumption

24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max.

100 to 240 VAC: 3.1 VA max.

Sensor inputs

Thermocouple: K, J, T, E;
Platinum-resistance thermometer: Pt100, Pt1000

Thermocouple: K, J, T, E, B, R, S, PL II

Setting method

Set of three rotary DIP switches

Indicators

Power (PWR): Green, Alarm (ALM): Red

Output form

Relay: SPDT contact output

Transistor: Open collector

Output relay ratings

Resistive load

5 A at 250 VAC
5 A at 30 VDC

Inductive load

1 A at 250 VAC
0.2 A at 48 VDC

Minimum load

5 VDC, 10 mA (reference values)

Mechanical life

10 million operations min.

Electrical life

5 A at 250 VAC or 30 VDC: 50,000 operations
3 A at 250 VAC/30 VDC: 100,000 operations

Transistor output ratings

Contact form

SPST-NO (Open collector)

Rated voltage

24 VDC (maximum voltage: 26.4 VDC)

Maximum current

50 mA DC

Ambient operating temperature

−20 to 60°C (with no condensation or icing)

Storage temperature

−25 to 65°C (with no condensation or icing)

Case material

PC, UL 94 V-0

Weight

Approx. 100 g

Size in mm (H × W × D)

90×17.5×90

Measurement accuracy

±1% of the setting range or ±4 °C, whichever is larger.

±1% of the setting range (±1%FS).

Hysteresis width

2°C

Sampling cycle

100 ms

Applicable standards

Approved standards

EN 61010-1

Installation environment: Overvoltage category II, pollution level 2

EMC

EN 61326-1

Safety standards

UL 61010-1 (Listing), Korean Radio Waves Act (Act 10564)

Degree of protection

Terminals: IP20


1.Industrial Electromagnetic Environment (EN/IEC 61326-1, Table 2)


Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.