View larger
TH2-63X60BL AA054445F TH263X60BL OMRON Flat LED Back light (15 mm), active area 63 x 60 mm, blue, 24 VDC
TH2-63X60BL
AA054445F
TH263X60BL
OMRON
1 Pcs.
Automation > Accessories/spare parts for sensor technology
Special
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A flat LED backlight provides uniform background illumination for machine vision applications, ensuring high-contrast silhouettes during automated dimensioning or flaw detection. The Omron TH2-63X60BL projects consistent blue illumination across a targeted active area to optimize image capture clarity. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- 24 VAC/DC: Thermocouple or platinum resistance thermometer
- Transistor: Open collector: K8DT-TH1TD
- 100-240 VAC: Relay: SPDT contact output
- Transistor: Open collector: K8DT-TH1TA
- 24 VAC/DC: Thermocouple
- Transistor: Open collector: K8DT-TH2TD
- 100-240 VAC: Relay: SPDT contact output
- Transistor: Open collector: K8DT-TH2TA
- Power supply voltage: K8DT-TH__D: 24 VAC 50/60 Hz or 24 VDC K8DT-TH__A: 100 to 240 VAC 50/60 Hz
- Allowable voltage range: 85% to 110% of power supply voltage
- Power consumption: 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max.
- Sensor inputs: Thermocouple: K, J, T, E
- Platinum-resistance thermometer: Pt100, Pt1000
- Setting method: Set of three rotary DIP switches
- Indicators: Power (PWR): Green, Alarm (ALM): Red
- Output form: Relay: SPDT contact output Transistor: Open collector
- Output relay ratings: Resistive load
More info
▲Temperature monitoring relay
Ideal to prevent heater overheating. Self-latching output to contribute to safe equipment operation.
- Set the temperature with ultra-simple rotary switches
- Digitally set the temperature to between 0 and 999°C in 1°C increments (K8DT-TH1__), or between 0 and 1,800°C in 10°C increments (K8DT-TH2__)
- Connect a thermocouple or platinum resistance thermometer
- Width of 17.5 mm to reduce space required in panels
- Push-in plus Technology that reduce wiring work
- UL listed for easy shipping to North America
- Double-insertion holes for crossover wiring (all terminals)
- Models added with transistor outputs for superior contact reliability
Ordering information
Power supply voltage | Input types | Setting units (setting range) | Output types | Order code |
|---|---|---|---|---|
24 VAC/DC | Thermocouple or platinum resistance thermometer | Setting unit: 1°C or 1°F | Relay: SPDT contact output | K8DT-TH1CD |
Transistor: Open collector | K8DT-TH1TD | |||
100-240 VAC | Relay: SPDT contact output | K8DT-TH1CA | ||
Transistor: Open collector | K8DT-TH1TA | |||
24 VAC/DC | Thermocouple | Setting unit: 10°C/°F | Relay: SPDT contact output | K8DT-TH2CD |
Transistor: Open collector | K8DT-TH2TD | |||
100-240 VAC | Relay: SPDT contact output | K8DT-TH2CA | ||
Transistor: Open collector | K8DT-TH2TA |
Accessories
Front Cover (Order separately)
Appearance | Order code |
|---|---|
Y92A-D1A |
Specifications
Item | K8DT-TH1 | K8DT-TH2 | |
|---|---|---|---|
Power supply voltage | K8DT-TH__D: 24 VAC 50/60 Hz or 24 VDC K8DT-TH__A: 100 to 240 VAC 50/60 Hz | ||
Allowable voltage range | 85% to 110% of power supply voltage | ||
Power consumption | 24 VAC or 24 VDC: 2.1 VA max. or 1.2 W max. 100 to 240 VAC: 3.1 VA max. | ||
Sensor inputs | Thermocouple: K, J, T, E; | Thermocouple: K, J, T, E, B, R, S, PL II | |
Setting method | Set of three rotary DIP switches | ||
Indicators | Power (PWR): Green, Alarm (ALM): Red | ||
Output form | Relay: SPDT contact output Transistor: Open collector | ||
Output relay ratings | Resistive load | 5 A at 250 VAC | |
Inductive load | 1 A at 250 VAC | ||
Minimum load | 5 VDC, 10 mA (reference values) | ||
Mechanical life | 10 million operations min. | ||
Electrical life | 5 A at 250 VAC or 30 VDC: 50,000 operations | ||
Transistor output ratings | Contact form | SPST-NO (Open collector) | |
Rated voltage | 24 VDC (maximum voltage: 26.4 VDC) | ||
Maximum current | 50 mA DC | ||
Ambient operating temperature | −20 to 60°C (with no condensation or icing) | ||
Storage temperature | −25 to 65°C (with no condensation or icing) | ||
Case material | PC, UL 94 V-0 | ||
Weight | Approx. 100 g | ||
Size in mm (H × W × D) | 90×17.5×90 | ||
Measurement accuracy | ±1% of the setting range or ±4 °C, whichever is larger. | ±1% of the setting range (±1%FS). | |
Hysteresis width | 2°C | ||
Sampling cycle | 100 ms | ||
Applicable standards | Approved standards | EN 61010-1 Installation environment: Overvoltage category II, pollution level 2 | |
EMC | EN 61326-1 | ||
Safety standards | UL 61010-1 (Listing), Korean Radio Waves Act (Act 10564) | ||
Degree of protection | Terminals: IP20 | ||
1.Industrial Electromagnetic Environment (EN/IEC 61326-1, Table 2)